Installation andGetting Started Guidewww.procurve.comProCurve Series6400cl Switches
1-2Introducing the SwitchIntroducing the SwitchThese switches are designed to be used primarily in a high-density wiring closet or in a data center. T
1-3Introducing the SwitchFront of the SwitchIntroducing the SwitchFront of the Switch Reset and Clear buttonsSwitch port LEDsPower and Fault LEDsConso
1-4Introducing the SwitchFront of the SwitchIntroducing the SwitchConsole Port This port is used to connect a console to the switch by using the seria
1-5Introducing the SwitchFront of the SwitchIntroducing the Switch Restoring Factory Default Configuration - When pressed with the Reset button in a
1-6Introducing the SwitchFront of the SwitchIntroducing the SwitchTable 1-2. RPS LED BehaviorRPS Status(green)OnBlinkingOffNormal operation. RPS is co
1-7Introducing the SwitchFront of the SwitchIntroducing the SwitchLocation of Status Indicator LEDs If the Link indicator LED is lit, each port LED d
1-8Introducing the SwitchFront of the SwitchIntroducing the SwitchExpansion cl Module LEDsExpansion cl Module LEDs refer to the LEDs specific to the e
1-9Introducing the SwitchBack of the SwitchIntroducing the SwitchBack of the SwitchThe back of both 6400cl Series switches look the same. cl Module Sl
1-10Introducing the SwitchSwitch FeaturesIntroducing the SwitchSwitch FeaturesThe features of the Series 6400cl Switch devices include: The Switch 64
2-1Installing the Switch2Installing the Switch The ProCurve Series 6400cl Switch devices come with an accessory kit that includes the brackets for mou
2-2Installing the SwitchIncluded PartsInstalling the Switch Power cord, one of the following:Japan Power Cord WarningPlease use the power cord suppli
2-3Installing the SwitchInstallation ProceduresInstalling the SwitchInstallation ProceduresSummary1. Prepare the installation site (page 2-5). Ensure
2-4Installing the SwitchInstallation ProceduresInstalling the SwitchInstallation Precautions:Follow these precautions when installing the Series 6400c
2-5Installing the SwitchInstallation ProceduresInstalling the Switch1. Prepare the Installation SiteCabling Infrastructure - Ensure the cabling infras
2-6Installing the SwitchInstallation ProceduresInstalling the Switch Installation Location - Before installing the switch, plan its location and orie
2-7Installing the SwitchInstallation ProceduresInstalling the Switch2. (Optional) Install or Remove a cl ModuleCaution It is recommended the power to
2-8Installing the SwitchInstallation ProceduresInstalling the Switch3. (Optional) Install or Remove a TransceiverWARNING The ProCurve X2 fiber optic t
2-9Installing the SwitchInstallation ProceduresInstalling the Switch4. Verify the Switch Passes Self TestBefore mounting the switch in its network loc
2-10Installing the SwitchInstallation ProceduresInstalling the Switch2. Check the LEDs on the switch as described below.When the switch is powered on,
2-11Installing the SwitchInstallation ProceduresInstalling the SwitchWhen the self test completes successfully:•The Power and Fan Status LEDs remain o
ProCurve Series 6400cl SwitchInstallation and Getting Started Guide
2-12Installing the SwitchInstallation ProceduresInstalling the SwitchRack Mounting the Series 6400cl Switch Devices WARNING For safe operation, use on
2-13Installing the SwitchInstallation ProceduresInstalling the Switch2. Hold the switch with attached brackets up to the rack and move it vertically u
2-14Installing the SwitchInstallation ProceduresInstalling the Switch7. Connect the Network CablesConnect the network cables, described under “Cabling
2-15Installing the SwitchInstallation ProceduresInstalling the Switch8. (Optional) Connect a Redundant Power Supply to the Switch The “ProCurve 60
2-16Installing the SwitchInstallation ProceduresInstalling the SwitchLEDsThe RPS LEDs are located on the back of the RPS/EPS. These LEDs are duplicate
2-17Installing the SwitchInstallation ProceduresInstalling the SwitchThe following picture demonstrates and example of connectivity between an RPS/EPS
2-18Installing the SwitchInstallation ProceduresInstalling the Switch9.(Optional) Connect a Console to the Switch The switch has a full-featured, easy
2-19Installing the SwitchInstallation ProceduresInstalling the SwitchDirect Console AccessTo connect a console to the switch, follow these steps:1. Co
2-20Installing the SwitchSample Network TopologiesInstalling the SwitchSample Network TopologiesThis section shows a few sample network topologies in
2-21Installing the SwitchSample Network TopologiesInstalling the SwitchRemote CampusLocal Site using 10-GbE SR or OMC up to 300m 6410clMain Office Dat
Hewlett-Packard Company8000 Foothills Boulevard, m/s 5552Roseville, California 95747-5552http://www.procurve.com© Copyright 2005, 2006 Hewlett-Packar
2-22Installing the SwitchSample Network TopologiesInstalling the SwitchFlexible StackingThe Series 6400cl Switch devices can be connected together in
2-23Installing the SwitchSample Network TopologiesInstalling the SwitchResiliency Using 6400cl Series as a meshed ClusterThe redundant topology increa
3-1Getting Started With Switch Configuration3Getting Started With Switch ConfigurationThis chapter is a guide for using the console Switch Setup scree
3-2Getting Started With Switch ConfigurationGetting Started With Switch ConfigurationNote By default, the switch is configured to acquire an IP addres
3-3Getting Started With Switch ConfigurationGetting Started With Switch Configuration4. [Tab] to the IP Config (DHCP/Bootp) field and use the Space ba
3-4Getting Started With Switch ConfigurationGetting Started With Switch ConfigurationWhere to Go From HereThe above procedure configures your switch w
3-5Getting Started With Switch ConfigurationUsing the IP Address for Remote Switch ManagementGetting Started With Switch ConfigurationUsing the IP Add
3-6Getting Started With Switch ConfigurationUsing the IP Address for Remote Switch ManagementGetting Started With Switch ConfigurationThe operating sy
4-1Troubleshooting4TroubleshootingThis chapter describes how to troubleshoot your switch. This document describes troubleshooting mostly from a hardwa
iiiContentsIntroducing the Switch Front of the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
4-2TroubleshootingBasic Troubleshooting TipsTroubleshooting Improper Network Topologies. It is important to make sure you have a valid network topolo
4-3TroubleshootingDiagnosing with the LEDsTroubleshootingDiagnosing with the LEDsTable 4-1 shows LED patterns on the switch and the switch modules tha
4-4TroubleshootingDiagnosing with the LEDsTroubleshootingDiagnostic Tips:Tip Problem Solution➊The switch is not plugged into an active AC power source
4-5TroubleshootingDiagnosing with the LEDsTroubleshooting➏The network connection is not working properly.Try the following procedures:• For the indica
4-6TroubleshootingProactive NetworkingTroubleshootingProactive NetworkingThe ProCurve Series 6400cl Switch devices have built-in management capa-bilit
4-7TroubleshootingHardware Diagnostic TestsTroubleshootingHardware Diagnostic TestsTesting the Switch by Resetting ItIf you believe the switch is not
4-8TroubleshootingHardware Diagnostic TestsTroubleshootingTesting Switch-to-Device Network CommunicationsYou can perform the following communication t
4-9TroubleshootingRestoring the Factory Default ConfigurationTroubleshootingRestoring the Factory Default ConfigurationAs part of your troubleshooting
4-10TroubleshootingDownloading New Switch SoftwareTroubleshootingDownloading New Switch Software When product enhancements occur for the switch, new s
4-11TroubleshootingProCurve Customer Support ServicesTroubleshootingProCurve Customer Support ServicesIf you are still having trouble with your switch
iv6. Connect the Switch to a Power Source . . . . . . . . . . . . . . . . . . . . . . 2-137. Connect the Network Cables . . . . . . . . . . . . . . .
A-1SpecificationsASpecificationsPhysical Electrical The switch automatically adjusts to any voltage between 100-240 volts and either 50 or 60 Hz. Envi
A-2SpecificationsSpecificationsAcousticGeraeuschemission LwA=55 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19Noise Emission LwA=55 dB at virtual wor
B-1Safety and EMC Regulatory StatementsBSafety and EMC Regulatory StatementsSafety InformationGroundingThese are safety class I products and have prot
B-2Safety and EMC Regulatory StatementsInformations concernant la sécuritéSafety and EMC Regulatory StatementsInformations concernant la sécuritéCet a
B-3Safety and EMC Regulatory StatementsHinweise zur SicherheitSafety and EMC Regulatory StatementsHinweise zur SicherheitDies ist ein Gerät der Sicher
B-4Safety and EMC Regulatory StatementsConsiderazioni sulla sicurezzaSafety and EMC Regulatory StatementsConsiderazioni sulla sicurezzaQuesto prodotto
B-5Safety and EMC Regulatory StatementsConsideraciones sobre seguridadSafety and EMC Regulatory StatementsConsideraciones sobre seguridadEste aparato
B-6Safety and EMC Regulatory StatementsSafety Information (Japan)Safety and EMC Regulatory StatementsSafety Information (Japan)Japan Power Cord Warnin
B-7Safety and EMC Regulatory StatementsSafety Information (China)Safety and EMC Regulatory StatementsSafety Information (China)
vRestoring the Factory Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . 4-9Downloading New Switch Software . . . . . . . . . .
B-8Safety and EMC Regulatory StatementsEMC Regulatory StatementsSafety and EMC Regulatory StatementsEMC Regulatory StatementsU.S.A.FCC Class AThis equ
B-9Safety and EMC Regulatory StatementsEMC Regulatory StatementsSafety and EMC Regulatory StatementsKoreaTaiwan
B-10Safety and EMC Regulatory StatementsEMC Regulatory StatementsSafety and EMC Regulatory StatementsEuropean CommunityDECLARATION OF CONFORMITY accor
C-1Recycle StatementsCRecycle StatementsWaste Electrical and Electronic Equipment (WEEE) StatementsDisposal of Waste Equipment by Users in Private Hou
C-2Recycle StatementsWaste Electrical and Electronic Equipment (WEEE) StatementsRecycle StatementsLaitteiden hävittäminen kotitalouksissa Euroopan uni
C-3Recycle StatementsWaste Electrical and Electronic Equipment (WEEE) StatementsRecycle StatementsSmaltimento delle apparecchiature da parte di privat
C-4Recycle StatementsWaste Electrical and Electronic Equipment (WEEE) StatementsRecycle StatementsDescarte de Lixo Elétrico na Comunidade Européia Es
Index – 1IndexNumerics10 Gigabit10-GbE … 1-1, 1-4, 1-10AAC power connectorlocation on back of switch … 1-9Act LED … 1-5, 1-7–1-8Bback of switchcl modu
2 – IndexIndexdescriptionback of switch … 1-9front of switch … 1-3LEDs … 1-5switch … 1-1DHCPautomatic switch configuration … 3-2for in-band access … 2
Index – 3Indexshowing error conditions … 4-3Link … 1-5, 1-7–1-8location on switch … 1-3on switch … 1-5portdescription … 1-5Port LED View select indica
viRecycle StatementsWaste Electrical and Electronic Equipment (WEEE) Statements . . . . . . C-1Index
4 – IndexIndexRedundant Power Supply … 2-15redundant power supplyRPS/EPS … 1-1regulatory statements … B-8remote campustopology with … 2-21Reset button
Index – 5Indextroubleshooting … 4-1basic tips … 4-1checking port configuration … 4-2checking the console messages … 4-7checking the LEDs … 4-7common n
Technical information in this documentis subject to change without notice.©Copyright 2004, 2006Hewlett-Packard Development Company, L.P.Reproduction,
1-1Introducing the Switch1Introducing the Switch The ProCurve Series 6400cl Switch are multiport switches that can be used to build high-performance s