HP 2324fc Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru HP 2324fc. HP 2324fc User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP StorageWorks
Carrier-Grade 2324fc Modular Smart Array
user guide
Part number: 5991-8050
second edition: March 2009
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - HP StorageWorks

HP StorageWorksCarrier-Grade 2324fc Modular Smart Array user guidePart number: 5991-8050second edition: March 2009

Strany 3 - Contents

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 11About this guideThis guide provides information about the HP StorageWorks 2324fc

Strany 4

12WARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that failure to follow directions could

Strany 5

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 13Product warrantiesFor information about HP StorageWorks product warranties, see

Strany 7

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 151OverviewThe 2324fc Modular Smart Array is a high-performance storage solution t

Strany 8

16 Overview

Strany 9

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 172ComponentsFront panel componentsMSA2324fc1 Enclosure ID LED2 Hard drive Online/

Strany 10

18 ComponentsHard drive bay numbersMSA2324fcRear panel components MSA2324fc1 Power supplies — AC 2 Power switches — AC3 Host ports4 CLI port 5 Etherne

Strany 11 - About this guide

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 19MSA2000 3.5 12-drive enclosureNOTE: The MSA2324fc can also be attached to an MSA

Strany 12 - Customer self repair

Legal and notice information© Copyright 2008-2009 Hewlett-Packard Development Company, L.P.The information combined herein is subject to change withou

Strany 13 - Documentation feedback

20 ComponentsCAUTION: To preserve the existing data stored in the CompactFlash, you must transport the CompactfFash from the failed controller to the

Strany 14

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 213Installing the enclosuresInstallation checklistThe following table outlines the

Strany 15 - 1Overview

22 Installing the enclosuresConnecting controller and MSA2000 3.5 12-drive enclosuresYou can connect up to three MSA2000 3.5 12-drive enclosures to an

Strany 16 - 16 Overview

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 23Figure 2 Cabling connections between a dual-controller enclosure and one MSA2000

Strany 17 - 2Components

24 Installing the enclosuresTesting enclosure connections 1. Press the power switches at the back of each drive enclosure to On.IMPORTANT: This ensure

Strany 18 - Rear panel components

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 251. From your network administrator obtain an IP address, subnet mask, and gatewa

Strany 19 - 13 4 5 12

26 Installing the enclosures6. At the prompt, type the following command to set the values you obtained in Step 1 for each Ethernet management port, f

Strany 20 - Super-capacitor pack

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 271. Attach the rear brackets to the MSA2324 Carrier-Grade (CG).2. Attach the left

Strany 21 - 3Installing the enclosures

28 Installing the enclosuresTable 5 Callout locations1Lock washer2Screw3Flat washer4Bolt5 Ground cable lug. Position between ear and rail (cable not s

Strany 22

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 298. Loosely attach the rear brackets to the rear bracket assemblies.9. Attach the

Strany 23

HP StorageWorks 2324fc Modular Smart Array user guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24 - Obtaining IP values

30 Installing the enclosures

Strany 25

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 274 Connecting hostsHost system requirementsData hosts connected to MSA2324fc arra

Strany 26

28 Connecting hostsTwo servers/one dual-ported HBA per server/dual pathConnecting switch attach configurations Two servers/two switchesConnecting remo

Strany 27

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 295 Basic operationPowering on/powering offBefore powering on the enclosure for th

Strany 29

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 316 LED descriptionsFront panel LEDsLED Description Definition1 Enclosure ID Green

Strany 30 - 30 Installing the enclosures

32 LED descriptionsHard drive LEDsLED Description1 Fault/UID (amber/blue)2Online/Activity (green)Table 5 Hard drive LED combinations Online/Activity (

Strany 31 - 4 Connecting hosts

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 33Blinking regularly (1 Hz) OffCAUTION: Do not remove the drive. Removing a drive

Strany 32 - Two servers/two switches

34 LED descriptionsRear panel LEDsMSA2324fcLED Description Definition1 Power supply LEDs See Power supply LEDs.2 Host Link Status/Activity FC port 1 B

Strany 33 - 5 Basic operation

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 3510 Cache Status Green — Cache is dirty (contains unwritten data) and operation i

Strany 34 - 30 Basic operation

46 LED descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Front panel LEDs. . . . .

Strany 35 - 6 LED descriptions

36 LED descriptionsMSA2000 3.5 12-drive enclosureLED Description Definition1 Power supply LEDs See Power supply LEDs.2 Unit Locator Off — Normal opera

Strany 36 - Hard drive LEDs

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 37Power supply LEDsPower redundancy is achieved through two independent load-shari

Strany 37

38 LED descriptions

Strany 38 - Rear panel LEDs

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 397 Configuring a system for the first timeConfiguring your web browser for SMUBef

Strany 39 - LED Description Definition

40 Configuring a system for the first timeTips for using the help window• In the main panel, clicking the help icon displays help for the last-selecte

Strany 40

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 41Using the Configuration WizardThe Configuration Wizard helps you initially confi

Strany 41 - Power supply LEDs

42 Configuring a system for the first timeUsing the Provisioning WizardThe Provisioning Wizard helps you create a vdisk with volumes and to map the vo

Strany 42 - 38 LED descriptions

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 438TroubleshootingFault isolation methodologyThe MSA2000 Family storage system pro

Strany 43

44 TroubleshootingCorrecting enclosure IDs When installing a system with drive enclosures attached, the enclosure IDs might not agree with the physica

Strany 44

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 45Are both drive module LEDs off (Online/Activity and Fault/UID)?Is the drive modu

Strany 45

HP StorageWorks 2324fc Modular Smart Array user guide 5Weight and placement guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 46 - Logging out of SMU

46 TroubleshootingIs a connected port’s Expansion Port Status LED off?Is a connected port’s Ethernet link status LED off?Is the power supply’s AC Powe

Strany 47 - 8Troubleshooting

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 47Is the drive enclosure back panel OK LED off?Is the drive enclosure Fault/Servic

Strany 48 - Diagnostic steps

48 TroubleshootingController failure in a single-controller configurationCache memory is flushed to CompactFlash in the case of a controller failure o

Strany 49

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 49Isolating a host-side connection fault During normal operation, when a controlle

Strany 50 - 46 Troubleshooting

50 TroubleshootingIsolating a controller module expansion port connection fault During normal operation, when a controller module’s expansion port is

Strany 51

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 51Sensor locationsThe storage system monitors conditions at different points withi

Strany 52 - Transporting Cache

52 TroubleshootingWhen a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log.Power suppl

Strany 53

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 53A. Parts catalogThis product contains the parts illustrated in Figure 4, Figure

Strany 54 - 50 Troubleshooting

54 Parts catalogFFigure 4 MSA2312fc exploded view Table 11 MSA2312fc parts list Item Description Spares part number CSRMandatoryOptional1 SPS-BLANK,HD

Strany 55 - Temperature sensors

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 557Power supplies — —SPS-POWER SUPPLY (AC) 481320-001 MandatorySPS-DC DISK ENCL, P

Strany 57 - A. Parts catalog

56 Parts catalogFigure 5 MSA2324fc exploded view Table 12 MSA2324fc parts list Item Description Spares part number CSRMandatoryOptional1 SPS-BLANK,HDD

Strany 58

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 577Power supplies — —a) SPS-POWER SUPPLY 481320-001 Mandatoryb) SPS-DC DISK ENCL,

Strany 59 - Optional

58 Parts catalogFigure 6 MSA2000 3.5 12-drive enclosure exploded viewTable 13 MSA2000 3.5 12-drive enclosure parts list Item Description Spares part n

Strany 60

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 59• For more information about CSR, contact your local service provider. For North

Strany 61

60 Parts catalog

Strany 62

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 61B Environmental requirements and specificationsSafety requirementsInstall the sy

Strany 63

62 Environmental requirements and specificationsWeight and placement guidelinesRefer to Physical requirements for detailed size and weight specificati

Strany 64 - 60 Parts catalog

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 63NOTE: Connections to this device must be made with shielded cables with metallic

Strany 65 - Safety requirements

64 Environmental requirements and specificationsElectrical requirementsSite wiring and power requirementsEach enclosure has two power and cooling modu

Strany 66 - Management host requirements

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 65C Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging t

Strany 67 - Environmental requirements

HP StorageWorks 2324fc Modular Smart Array user guide 7Figures1 Cabling connections between a single-controller enclosure and one MSA2000 3.5 12-driv

Strany 68 - Electrical requirements

66 Electrostatic discharge

Strany 69 - C Electrostatic discharge

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 67D Regulatory compliance and safetyRegulatory complianceFederal Communications Co

Strany 70 - 66 Electrostatic discharge

68 Regulatory compliance and safety• 1-281-514-3333To identify this product, refer to the part, Regulatory Model Number, or product number found on th

Strany 71 - Regulatory compliance

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 69Laser product labelThe optional label in Figure 6-1 or equivalent may be located

Strany 72

70 Regulatory compliance and safetyBSMI noticeJapanese noticeKorean noticesSafetyBattery replacement noticeYour computer is equipped with a lithium ma

Strany 73 - European Union notice

HP StorageWorks Carrier-Grade 2324fc Modular Smart Array user guide 71WARNING! Yur computer contains an internal lithium manganese dioxide, a vanadium

Strany 74 - Battery replacement notice

72 Regulatory compliance and safety• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.• Place part

Strany 75 - Electrostatic discharge

HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 73IndexAaccessingthe CLI 24accessing the SMU 39accumulators 71audience 11Avis Canadie

Strany 76 - Grounding methods

74Ffaultsisolatinga host-side connection 49expansion port connection fault 50methodology 43FCC (Federal Communications Commission)Class A Equipment, c

Strany 77

HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide 75physical requirements 63point-to-point topology 27portsMSA2000 3.5 12-drive enclosu

Strany 79

76Wwarningslasers, radiation 68rack stability 12voltage and temperature 50web sitesHP documentation 11HP storage 13HP Subscriber’s choice 13web-browse

Strany 80

HP StorageWorks 2324fc Modular Smart Array user guide 9Tables1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Komentáře k této Příručce