HP 470065-542 Datový list

Procházejte online nebo si stáhněte Datový list pro Servery HP 470065-542. HP ProLiant DL160 G6 Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 58
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memory
intense High Performance Computing (HPC) environments, Web 2.0, hosting, and general large memory footprint server
deployments.
Hot Plug SAS/SATA and Non-Hot Plug SATA Models
Hot Plug SAS/SATA and Non-Hot Plug SATA ModelsHot Plug SAS/SATA and Non-Hot Plug SATA Models
Hot Plug SAS/SATA and Non-Hot Plug SATA Models
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Access panel
1.
Power Supply Cable Socket
2.
System fans
2.
Video Port
3.
Two USB ports
3.
Serial Port
4.
Power on/off & system LEDs
4.
Rear USB ports (2)
5.
Optional 3
rd
and 4
th
3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays
5.
One GbE LAN ports for shared NIC 2 (RJ-45)
6.
Optional DVD-RW or DVD-ROM drive
6.
Optional LO100i 10/100 Mbps LAN port for dedicated
IPMI management (RJ-45)
7.
Standard 1st and 2nd 3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays (Small Form Factor drive cage
not shown here. See the Storage Section for orientation of
eight small form factor drive option)
7.
Low-Profile slot cover (not used in this model)
8.
Full-height PCI-Express x16
9.
UID - Rear Unit Identification LED
10.
One GbE LAN ports for NIC 1 (RJ-45)
8.
Eighteen DIMM slots : DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
9.
Expansion Slots:
Slot 1:Full-length/Full height x16 PCI-Express Gen2 slot, or
Slot 1: Half-length/Full height x16 PCI-Express Gen2 slot
and
Slot 2: Low Profile x4 PCI-Express Gen2 slot (accepts x8
cards, internal only)
10.
Six Core Intel® Xeon® 5600 ,Quad-Core Intel® Xeon®
5600 & Quad-Core Intel® Xeon® 5500 series processors
(supports up to two)
11.
Power supply (500 Watts - standard, other PS options
available)
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
Overview
DA - 13247 Worldwide — Version 55 — January 9, 2012
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 57 58

Shrnutí obsahu

Strany 1 - QuickSpecs

The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memoryintense High Performanc

Strany 2

HP Insight Management Agents for Systems Insight Manager (SIM)IntegrationHP Systems Management HomepageArray Configuration Utility (ACU)Array Diagnost

Strany 3

HP EnterpriseHP EnterpriseHP EnterpriseHP EnterpriseConfiguratorConfiguratorConfiguratorConfiguratorThe HP eConfigure Enterprise Configurator now prov

Strany 4

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Strany 5

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Strany 6

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strany 7

X5650 2P 24GB-RX5650 2P 24GB-RX5650 2P 24GB-RX5650 2P 24GB-RP410/256 BBWC 8 SFFP410/256 BBWC 8 SFFP410/256 BBWC 8 SFFP410/256 BBWC 8 SFF500W PS Server

Strany 8

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Strany 9

Tool-less Fixed Rails NOTE:NOTE:NOTE:NOTE: SFF CTO Chassis (P/N: 593352-B21) is not configurable with 130W Intel®Xeon® Processor Models. Step 2: Choos

Strany 10

8SFF drive cage is not supported when 130W processors are installedNo Fan redundancy is available when 130W Processors are installed.Change fan locati

Strany 11

HP Hard DrivesHP Hard DrivesHP Hard DrivesHP Hard DrivesNOTE:NOTE:NOTE:NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller

Strany 12

What's NewWhat's NewWhat's NewWhat's NewSupport for SAS Hot Plug 2.5" Enterprise Mainstream Hard DrivesQuickSpecsHP ProLiant

Strany 13

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesNOTE:NOTE:NOTE:NOTE: Prior to making a power supply selection it is highly recomme

Strany 14

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strany 15

NOTE:NOTE:NOTE:NOTE: HT indicates that the processor model supports Intel® Hyper-ThreadingTechnology.NOTE:NOTE:NOTE:NOTE: Turbo indicates the maximum

Strany 16

HP Drive Cage OptionsHP Drive Cage OptionsHP Drive Cage OptionsHP Drive Cage OptionsHP 4 Hard Drive Hot Plug Backplane G6 KitNOTE:NOTE:NOTE:NOTE: Inst

Strany 17

NOTE:NOTE:NOTE:NOTE: Please see QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13021_

Strany 18

SAS Non Hot Plug (3.5") LFF Enterprise (ENT) DrivesSAS Non Hot Plug (3.5") LFF Enterprise (ENT) DrivesSAS Non Hot Plug (3.5") LFF Enter

Strany 19

HP NetworkingHP NetworkingHP NetworkingHP NetworkingGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet Adapte

Strany 20

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strany 21

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster Management UtilityHP Cluster Management Uti

Strany 22

HP I/O AcceleratorHP I/O AcceleratorHP I/O AcceleratorHP I/O AcceleratorOptionsOptionsOptionsOptionsHP 160GB Single Level Cell PCIe ioDrive for ProLia

Strany 23

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Strany 24

HP Smart Array P411/512 FBWC 2-ports Ext PCIe x8 SAS Controller578229-B21Smart Array P812 ControllerSmart Array P812 ControllerSmart Array P812 Contro

Strany 25

HP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBandQLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA583211-B21HP InfiniBand 4X DDR PCI-E Dual Port HCA4

Strany 26

HP Disk BackupHP Disk BackupHP Disk BackupHP Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of D2D Backup Systems see:http://www.hp.com/go/d2d

Strany 27

HP U320e SCSI Dual Channel Host Bus AdapterNOTE:NOTE:NOTE:NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi-drive MSL tape

Strany 28

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/14

Strany 29

NOTE:NOTE:NOTE:NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection andManagement page. Under Power Cords, click on the &qu

Strany 30

HP Rack OptionsHP Rack OptionsHP Rack OptionsHP Rack OptionsHP KVM SwitchesHP KVM SwitchesHP KVM SwitchesHP KVM SwitchesHP Server Console 0x2x8 Port A

Strany 31

HP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHardware Services 4-Hour On-site ServiceHardware Services 4-Hour O

Strany 32

HP ProLiant DL160 G6 (all models)HP ProLiant DL160 G6 (all models)HP ProLiant DL160 G6 (all models)HP ProLiant DL160 G6 (all models)NOTE:NOTE:NOTE:NOT

Strany 33

DIMM slot/capacity/populated speed tableDIMM slot/capacity/populated speed tableDIMM slot/capacity/populated speed tableDIMM slot/capacity/populated s

Strany 34

Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W, DDR3-1066) ProcessorNOTE:NOTE:NOTE:NOTE: Available through Configure To Order only. See Factory Integratio

Strany 35

18 DIMM SLOTS (9 per CPU node)18 DIMM SLOTS (9 per CPU node)18 DIMM SLOTS (9 per CPU node)18 DIMM SLOTS (9 per CPU node) CPU1CPU1CPU1CPU1 CPU2CPU2CPU2

Strany 36

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; 8GB DIMM1G; emptyChnl 12D; 8GB DIMM2D; empty3A; 2GB DIMM3A;

Strany 37

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 4GB DIMM2D; empty3A; 4GB DIMM3A; em

Strany 38

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 4GB DIMM2D; 4GB DIMM3A; 4GB DIMM3A;

Strany 39

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Follo

Strany 40

1-4Four Non-hot plug SATA or four 3.5" Hot-plugSAS/SATA hard drive baysAOptional DVD-ROM, or DVD RW1-8Eight Hot-plug SATA/SAS hard drive baysAOpt

Strany 41

QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionPositionPositionSupportedSupportedSupportedSupportedControllerCon

Strany 42

300GB 6G SAS 15K300GB 6G SAS 10K450GB 6G SAS 7.2K146GB 6G SAS 15K72GB 6G SAS 15KHP Smart Array P812/1G Flash Backed Cache ControllerSAS Hot Plug LFF (

Strany 43

400GB 6G SAS SLC SFFSSD200GB 6G SAS SLC SFFSSDUp to 41-4HP Smart Array P212 ControllerHP Smart Array P410 ControllerHP Smart Array P812/1G Flash Backe

Strany 44

HP USB Tape DrivesHP USB Tape DrivesHP USB Tape DrivesHP USB Tape DrivesDAT 40DAT 72DAT 160DAT 3201U USB Rack-Mount KitExternalUSB 2.0 PortN/A HP SA

Strany 45

MemoryMemoryMemoryMemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)Standard (Entry Models)4 GB (1 x 4 GB) RDIMMsStandard (Base Models)8 GB (2 x

Strany 46

HP USB RDX RemovableHP USB RDX RemovableHP USB RDX RemovableHP USB RDX RemovableDisk Backup SystemDisk Backup SystemDisk Backup SystemDisk Backup Syst

Strany 47

HP 750W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with BackplaneHP 750W Common Slot Gold Hot Plug Factory Integrated Power Supply

Strany 48

HP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with BackplaneHP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply

Strany 49

HP 460W Common Slot Platinum Hot Plug Power Supply Kit with BackplaneHP 460W Common Slot Platinum Hot Plug Power Supply Kit with BackplaneHP 460W Comm

Strany 50

PowerPowerPowerPower ProLiant DL160 G6 Fully ConfiguredProLiant DL160 G6 Fully ConfiguredProLiant DL160 G6 Fully ConfiguredProLiant DL160 G6 Fully C

Strany 51

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68

Strany 52

installed.System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate

Strany 53

HP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATA7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5

Strany 54

Smart Array P410/410iSmart Array P410/410iSmart Array P410/410iSmart Array P410/410iControllerControllerControllerControllerDisk Drive and EnclosureDi

Strany 55

upgrade (for the 256MB cache), and Smart Array Advanced Pack (SAAP).NOTE:NOTE:NOTE:NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advan

Strany 56

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE Su

Strany 57

Embedded SystemsEmbedded SystemsEmbedded SystemsEmbedded SystemsManagementManagementManagementManagementHP Lights-Out 100HP Lights-Out 100HP Lights-Ou

Strany 58

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight Control forLinuxHP Insi

Komentáře k této Příručce

Žádné komentáře