HP 572832-425 Datový list

Procházejte online nebo si stáhněte Datový list pro Servery HP 572832-425. HP ProLiant DL180 G6 X5504 1P 2GB-U 1x500GB SATA 460W PS Server/TV Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 41
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Front View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
Support for SAS and SATA Hot Plug SFF Midline (MDL) Drives
At A Glance
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Processors
:
Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache
Intel® 5520 Chipset
Memory
:
Up to 96GB, using PC3-8500R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully populated at 2
DIMMs per Channel in 12 slots.
Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at
2 DIMMs per Channel in 12 slots
Internal Drive Support
:
Support for up to twenty-five (25) SFF with a Smart Array controller.
Support for up to fourteen (14) LFF with a Smart Array controller:
Hot Plug Serial ATA (SATA) Models: Up to 14.0TB (14 x 1TB Hot Plug 3.5" hard drives)
Hot Plug Serial Attached SCSI (SAS) Models: SAS Model: Up to 14.0TB (14 x 1TB Hot Plug 3.5" hard drives)
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
DA - 13248 Worldwide QuickSpecs — Version 7 — 7.13.2009
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 40 41

Shrnutí obsahu

Strany 1 - QuickSpecs

Front View:Rear View:1.Access panel1.Redundant Power Supply Bay (Optional)2.Front LED Indicators2.Power Supply Cable Socket3.Power on/off3.Low Profile

Strany 2

System Fans4 system fans ship standard; Non-hot plug, Non-redundantNOTE: Redundant fan kit (P/N 516009-B21) available for purchase.Operating Systems a

Strany 3

Factory Express Portfoliofor Servers and StorageHP Factory Express offers configuration, customization, integration and deployment services for HP ser

Strany 4

NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL165 G6 under the Cluster Platformproduct portfolio. These hig

Strany 5

Four Drive Serial ATA (SATA) ModelsNOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of a

Strany 6

Twelve Drive Serial ATA (SATA) ModelsNOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (488234-B21)HP DL180G6 E5540

Strany 7

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Strany 8

MemoryRegistered RDIMMsHP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP 8GB 2Rx4

Strany 9

Step 3: Choose Additional Factory Integratable Options (only one from each list unlessotherwise noted)Rear DVD KitHP DL180G6 Rear DVD Cage KitNOTE: Th

Strany 10

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additionalinformation.Unique OptionsHP

Strany 11

MemoryRegistered RDIMMsHP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP 8GB 2Rx4

Strany 12

NOTE: Four (4), eight (8) and twelve (12) hard drives models are supported standard via BTO. Eight (8) andtwelve (12) hard drive model support require

Strany 13

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_d

Strany 14

Server ManagementStand Alone SoftwareProductsHP Lights-Out 100i Advanced Pack HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 2

Strany 15

Storage ControllersSAS Controllers HP Smart Array P800 HP Smart Array P800/512 BBWC Controller381513-B21NOTE: The HP Smart Array P800 controller provi

Strany 16

HPC Specific OptionsHP IB 4X DDR Conn-X PCI-e G2 Dual Port HCA483514-B21HP IB 4X DDR PCI-e DUAL PORT HCA448397-B21HP IB 4X QDR PCI-e G2 Dual Port HCA5

Strany 17

HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive LibraryAH560ANOTE: Please see the QuickSpecs for Technical Specifications and additionalinformat

Strany 18

HP StorageWorksModular Smart ArrayMSA SAN Storage ArraysHP StorageWorks 50 Modular Smart ArrayNOTE: Please see the QuickSpecs for Technical Specificat

Strany 19

HP Rack SeriesHP Rack 10000 G2 Series (Carbon/Graphite Metallic)10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock PalletAF034A10642 G2 (42U) Rack Cabine

Strany 20

USB OptionsUSB 1.44-MB External Diskette DriveDC141BUSB Floppy DriveDC361BHP USB-PS/2 MouseDC369AHP Keyboard (USB) standard 2004DT528A#xxxService and

Strany 21

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6Standard Memory (depending on model)4 GB

Strany 22

DIMM Type ->Registered DIMMS (RDIMMs)Unbuffered with ECCDIMMs (UDIMMs)DIMM Rank ->Dual Rank (2R)Quad Rank(4R)Single Rank(1R)Dual Rank(2R)DIMM Ca

Strany 23

Tool-less access to all system components for easy in rack serviceabilityCustomer Self Repair (CSR): HP products are designed with many CSR parts to m

Strany 24

Standard memory configuration (1 CPU model)6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs CPU1 CPU2 slot #population orderslot #populati

Strany 25

UDIMM maximum configuration (1 CPU model)12GB, consisting of six (6) 2GB dual-rank PC3-10600 UDIMMs CPU1 CPU2 slot #population orderslot #population

Strany 26

4GB = 4096MB8GB = 8192MBFor detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool:www.hp.com/go/ddr

Strany 27

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Strany 28

drive cage +Rear Drive CageHP Smart Array P212/256 MB ControllerNOTE: Smart Array P212 Controllers recommended.HP Smart Array P800/512 BBWC Controller

Strany 29

400GB 3G 10K450GB 3G 15K300GB 3G 15K146GB 3G 15K72GB 3G 15KUp to 8 with 8drive cage1-8HP Smart Array P212/Zero Memory ControllerHP Smart Array P212/25

Strany 30

Tape Drives, ExternalDAT 160 SASLTO-2 Ultrium 448 SASLTO-3 Ultrium 920 SASLT0-4 Ultrium 1760 SASLTO-4 Ultrium 1840 SAS1U Rack-Mount Kit3U Rack-Mount K

Strany 31

HP 460W Power SupplyPart Number - AC 460W PSU503296-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal Input Voltage (V

Strany 32

System UnitDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)Weight(approximate)Maximum(all hard dr

Strany 33

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange i

Strany 34

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryIntegrated Models&qu

Strany 35

HP 160GB 3G SATA7.2K 3.5" ETY HDD458945-B21160GB 7,200 rpmCapacity160,041MBHeight1.04 in (26.4 mm)Width4.36 in (110.7 mm)Depth7.25 in (184.2 mm)I

Strany 36

Smart Array P410/410iControllerDisk Drive and EnclosureInterface3G SAS (Serial Attached SCSI)1.5G SATA (Serial ATA)SAS Connectors2 internal (Mini-SAS)

Strany 37

MemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)Standard4 GB(2 x 2 GB)6 GB(3 x 2 GB)12 GB(6 x 2 GB)Maximum (RDIMM)96 GB(12 x 8 GB)Maximum (UDIM

Strany 38

Storage Controller4HDD ModelsHP Embedded SATA RAID Controller (integrated into the south-bridge)supporting SW RAID 0,1,10NOTE: Transfer rate up to 3.0

Strany 39

InterfacesParallelNoneNetwork RJ-45 (Ethernet)2 10/100/1000 NIC ports (plus 1 dedicated for the HP ProLiant Lights Out100i Remote Management)Serial1Po

Strany 40

Core InfrastructureManagementHP Insight Control (ICE)suitesHP Insight Control suite for Linux (ICE-LX), as a product option, deliversessential infrast

Strany 41

Server Power CordsOne 6' Highline (IEC-IEC) power cord ships standardNOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (

Komentáře k této Příručce

Žádné komentáře