The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
What's NewWhat's New
What's New
Support for 6G SAS Hot Plug Enterprise Performance and Mainstream Solid State Drives
Support for HP NC552SFP 10Gb 2-port Ethernet Server Adapter
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
Overview
DA - 13248 North America — Version 36 — June 22, 2011
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - QuickSpecs

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellenceand 2U density for

Strany 2

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Strany 3

HP Insight ControlHP Insight ControlHP Insight ControlHP Insight Controlmanagement softwaremanagement softwaremanagement softwaremanagement softwareHP

Strany 4

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Strany 5

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Strany 6

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Strany 7

Four Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsNOTE:NOTE:

Strany 8

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite supportEight Drive

Strany 9

Twelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsNO

Strany 10

P410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFF750W PS Server750W PS Server750W PS Server750W PS Server590640-001Cach

Strany 11

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Strany 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryInteg

Strany 13

S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E55408GB 8LFF8GB 8LFF8GB 8LFF8GB 8LFF532078-005Processor(s)Processor(s)Processo

Strany 14

S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X566024GB 12LFF24GB 12LFF24GB 12LFF24GB 12LFF605664-005Processor(s)Processor(s)

Strany 15

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Strany 16

Step 2: Choose Required Options (only one of the following from each list unless otherwiseStep 2: Choose Required Options (only one of the following f

Strany 17

HP MemoryHP MemoryHP MemoryHP MemoryRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsHP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-13

Strany 18

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesNOTE:NOTE:NOTE:NOTE: Many HP ProLiant Servers now offer new power options, includi

Strany 19

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strany 20

HP DL180 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) Processor Kit590605-B21HP DL180 G6 Intel® Xeon® L5520 (2.26GHz/4-core/8MB/60W) Processor Kit5

Strany 21

HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LPMemory Kit627812-B21Unregistered with ECC UDIMMsUnregistered with ECC UDIMMsUn

Strany 22

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive S-Buy507127-S21HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Ent

Strany 23

Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W, DDR3-800) ProcessorNOTE:NOTE:NOTE:NOTE: Available through Configure To Order only. See Factory Integration

Strany 24

HP 800GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty SolidState Drive632506-B21NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Tec

Strany 25

HP NetworkingHP NetworkingHP NetworkingHP NetworkingGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet Adapte

Strany 26

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Strany 27

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster Management UtilityHP Cluster Management Uti

Strany 28

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option488069-B21NOTE:NOTE:NOTE:NOTE: The TPM (Trusted P

Strany 29

HP 512MB P-Series Battery Backed Write Cache UpgradeNOTE:NOTE:NOTE:NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411Controller

Strany 30

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareData Protector Express

Strany 31

HP Disk BackupHP Disk BackupHP Disk BackupHP Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of D2D Backup Systems see:http://www.hp.com/go/d2d

Strany 32

Converged Network AdapterConverged Network AdapterConverged Network AdapterConverged Network Adapter HP StorageWorks CN1000E Dual Port Converged Netwo

Strany 33

NOTE:NOTE:NOTE:NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection andManagement page. Under Power Cords, click on the &qu

Strany 34

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsSlot NumberSlot NumberSlot NumberSlot NumberBus SpeedBus SpeedBus SpeedBus SpeedBus Number

Strany 35

HP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 SeriesHP Rack 10000 G2 Series (

Strany 36

HP Rack OptionsHP Rack OptionsHP Rack OptionsHP Rack OptionsHP Server Console SwitchesHP Server Console SwitchesHP Server Console SwitchesHP Server Co

Strany 37

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6HP ProLiant DL180 G6HP Pro

Strany 38

DIMM Type ->Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMsUnbuffered

Strany 39

12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node) CPU1CPU1CPU1CPU1 CPU2CPU2CPU2

Strany 40

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 16GB DIMM1D: emptyChnl 12A: 16GB DIMM2A: empty Ch

Strany 41

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 4GB DIMM1D: 4GB DIMMChnl 12A: 4GB DIMM2A: 4GB DIMM

Strany 42

HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7Memory Kit500666-B21HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered

Strany 43

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Strany 44

HP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerHP Smart Array Hot Plug Advance Pac

Strany 45

(P/N: 516471-B21) is required to enable RAID 6, 6+0NOTE:NOTE:NOTE:NOTE: To achieve highest possible stated transfer rate please make sure the firmware

Strany 46

HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC

Strany 47

HP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerUp to 14 with 12drive cage +Rear Drive Cage1-14HP Smart Array P212/256 MB

Strany 48

400GB 6G SAS SLC200GB 6G SAS SLCUp to 41-4HP Smart Array P212 ControllerHP Smart Array P410 ControllerHP Smart Array P812/1G Flash Backed Cache Contro

Strany 49

HP USB Tape DrivesHP USB Tape DrivesHP USB Tape DrivesHP USB Tape DrivesDAT 40DAT 72DAT 160DAT 3201U USB Rack-Mount KitExternalUSB 2.0 PortN/A

Strany 50

HP USB RDX RemovableHP USB RDX RemovableHP USB RDX RemovableHP USB RDX RemovableDisk Backup SystemDisk Backup SystemDisk Backup SystemDisk Backup Syst

Strany 51

HP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply Kit

Strany 52

HP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Powe

Strany 53

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in

Strany 54

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operatingNon-operatingNon-operatingNon-operating-30° to 60°C (

Strany 55

HP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATA7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5

Strany 56

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE Su

Strany 57

Smart Array P410/410iSmart Array P410/410iSmart Array P410/410iSmart Array P410/410iControllerControllerControllerControllerDisk Drive and EnclosureDi

Strany 58

System FansSystem FansSystem FansSystem Fans4 system fans ship standard; Non-hot plug, Non-redundantNOTE:NOTE:NOTE:NOTE: Redundant fan kit (P/N 516009

Strany 59

models support the SmartStart Scripting Toolkit (SSSTK), an automatedscalable deployment utility.Information on core management supported on ProLiant

Strany 60

controllers and storage devices and testing of array controllerhardwareSmartStart Scripting Toolkit (SSSTK) and Smart Components forsoftware and drive