HP IO Accelerator Version 3.2.3 VMware ESX
and ESXi
User Guide
Abstract
This document describes software requirements for all relevant HP IO Accelerators using VMware ESX or ESXi operating systems.
This document is
intended for system administrators who
plan to install and use HP IO Accelerators with a VMware ESX or ESXi operating system. It is helpful to have
previous experience with HP IO Accelerators and a VMware ESX or ESXi operating system. This user guide is intended for IO Acc
elerator software
release 3.2.3 or later.
Part Number: 682240-002
March 2013
Edition: 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 56 57

Shrnutí obsahu

Strany 1 - User Guide

HP IO Accelerator Version 3.2.3 VMware ESX and ESXi User Guide Abstract This document describes software requirements for all relevant HP IO Acceler

Strany 2

Introduction 10 The IO Accelerators (QK761A, QK762A, and QK763A) for Gen 8 BladeSystem c-Class have the power cut functionality embedded on the card

Strany 3 - Contents

Introduction 11 Average block size (bytes) Minimum system RAM requirement for 640 GB MezzIO Accelerator* Minimum system RAM requirement for 785 GB M

Strany 4 - Contents 4

Software installation 12 Software installation VMDirectPathIO The VSL software is only required for ESX or ESXi if you plan to use the IO Accelerato

Strany 5 - About this guide

Software installation 13 Installation overview Before installing the IO Accelerator driver, make sure you have properly installed the IO Accelerator

Strany 6 - Introduction

Software installation 14 Transferring the VSL files to the ESX or ESXi server You must transfer the firmware file to the ESX or ESXi host. Depending

Strany 7 - Performance attributes

Software installation 15 Installing the VSL on ESXi 5.0 These instructions describe how to install the VSL on a single hypervisor. However, if you a

Strany 8 - Supported firmware revisions

Software installation 16 Installing the VSL on ESX or ESXi 4.x using vCLI IMPORTANT: Do not save the installation bundles to the ESX or ESXi 4.x

Strany 9 - Supported hardware

Software installation 17 NOTE: When using PCI pass-through, if you upgrade the firmware on an IO Accelerator, you must cycle the power for the ch

Strany 10

Software installation 18 CAUTION: Upgrading IO Accelerator devices that were previously configured for VSL 1.x.x or 2.x.x to work with VSL 3.x.x r

Strany 11 - Before you begin

Software installation 19 4. Update the firmware on each device to the latest version using the fio-update-iodrive TSM or COS command-line utility.

Strany 12 - Software installation

© Copyright 2012, 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strany 13 - Installation overview

Software installation 20 CAUTION: ESX and ESXi require 512B sector sizes. New IO Accelerator devices come pre-formatted with 512B sector sizes fro

Strany 14 - • SCP (using SSH)

Software installation 21 An ESXi host has the following: • Memory capacity of 36,852 MB • Total IO Accelerator device datastore capacity of 320 GB

Strany 15

Maintenance 22 Maintenance Maintenance tools The IO Accelerator includes both software utilities to maintain the device and external LED indicators

Strany 16

Maintenance 23 Command line utility Purpose fio-format (on page 32) Used to perform a low-level format of an IO Accelerator fio-pci-check (ESX only)

Strany 17 - Upgrading procedure

Maintenance 24 Important considerations • If you are installing more than one dual IO Accelerator device and enabling the override parameter for ea

Strany 18

Maintenance 25 1149D0969,1159E0972,24589 NOTE: The remote option (--server) is only required for the vCLI. 3. Reboot the system to enable the

Strany 19 - Enabling PCIe power

Maintenance 26 Disabling auto attach When the IO Accelerator driver is installed, it is configured to automatically attach any devices when the driv

Strany 20

Maintenance 27 vihostupdate --server <server-name> --query Sample output: ---------Bulletin ID--------- iomemory-vsl-2.2.0.7601742 -----Instal

Strany 21 - Software installation 21

Performance and tuning 28 Performance and tuning Introduction to performance and tuning HP IO Accelerator devices provide high bandwidth and high IO

Strany 22 - Maintenance

Utilities 29 Utilities Utilities reference These command-line utilities are only accessible through VMware TSM, also known as SSH, on ESXi and the C

Strany 23 - Enabling PCIe power override

Contents 3 Contents About this guide ...

Strany 24

Utilities 30 NOTE: If multiple IO Accelerator devices are installed in a computer, they attach in parallel. Syntax fio-attach <device> [

Strany 25 - Common maintenance tasks

Utilities 31 NOTE: If the utility recommends that you contact Fusion-io support, disregard that message and contact HP support (http://www.hp.com

Strany 26 - Enabling auto attach

Utilities 32 For example, the filename for a bug report file named fio-bugreport-20111006.173256-sc07HE.tar.gz indicates the following: • Date (201

Strany 27 - Unmanaged shutdown issues

Utilities 33 Syntax fio-format [options] <device> where <device> is the name of the device node (/dev/fctx), where x indicates the card

Strany 28 - Performance and tuning

Utilities 34 fio-pci-check [options] Options Description -d <value> 1 = Disable the link; 0 = bring the link up (HP does not recommend this

Strany 29 - Utilities

Utilities 35 IMPORTANT: Starting with version 3.0.0 and later, the standard formatting of the fio-status output changed. The changing of the forma

Strany 30

Utilities 36 o Date of manufacture o Power loss protection status o PCIe bus voltage (average, minimum, maximum) o PCIe bus current (average, max

Strany 31 - Utilities 31

Utilities 37 To ensure a clean firmware update, you must detach the device from the system using the fio-detach utility. For more information, see &

Strany 32 - • Date (20111006)

Utilities 38 CAUTION: Use the -f option with care because it might damage your board. CAUTION: Use the {{-d}} option with care, because upda

Strany 33

Monitoring IO Accelerator health 39 Monitoring IO Accelerator health NAND flash and component failure The IO Accelerator is a highly fault-tolerant

Strany 34

Contents 4 Introduction to performance and tuning ...

Strany 35 - Utilities 35

Monitoring IO Accelerator health 40 Lifetime data volumes: Physical bytes written: 6,423,563,326,064 Physical bytes read : 5,509,006,756,312 Fl

Strany 36 - • Block device information

Module parameters 41 Module parameters Using module parameters The following table describes the module parameters you can set using the esxcfg-modu

Strany 37

VMDirectPathIO 42 VMDirectPathIO Working with IO Accelerators and VMDirectPathIO Each IO Accelerator device can either be used as a VMFS datastore i

Strany 38 - Utilities 38

Resources 43 Resources Subscription service HP recommends that you register your product at the Subscriber’s Choice for Business website (http://www

Strany 39 - Health monitoring techniques

Support and other resources 44 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strany 40

Support and other resources 45 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strany 41 - Module parameters

Support and other resources 46 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Strany 42 - VMDirectPathIO

Support and other resources 47 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Strany 43 - Resources

Support and other resources 48 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strany 44 - Support and other resources

Support and other resources 49 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strany 45

About this guide 5 About this guide Contents summary • Instructions on downloading and installing the approved driver and utilities • Instructions

Strany 46 - Customer Self Repair

Support and other resources 50

Strany 47

Support and other resources 51

Strany 48 - Reparo feito pelo cliente

Regulatory information 52 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strany 49

Acronyms and abbreviations 53 Acronyms and abbreviations CIM common information model COS console operating system DVFS dynamic voltage and freque

Strany 50

Acronyms and abbreviations 54 VMFS virtual machine file system VSL virtual storage layer VUM VMware Update Manager WBEM Web-Based Enterprise Mana

Strany 51

Documentation feedback 55 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Strany 52 - Regulatory information

Index 56 A about this guide 5 authorized reseller 44 B battery replacement notice 52 before you begin 11 C command-line installation 12 co

Strany 53 - Acronyms and abbreviations

Index 57 PCIe power, enabling 19 performance and tuning 28 performance and tuning, introduction 28 performance attributes 7 phone numbers

Strany 54 - VMware Update Manager

Introduction 6 Introduction Overview Designed around ioMemory, a revolutionary storage architecture, HP IO Accelerator is an advanced NAND flash sto

Strany 55 - Documentation feedback

Introduction 7 • QK762A: HP 785GB IO MLC Accelerator for BladeSystem c-Class • QK763A: HP 1.2 TB IO MLC Accelerator for BladeSystem c-Class IMP

Strany 56 - Index 56

Introduction 8 NOTE: MSI was disabled to obtain these statistics. Required operating environment The HP IO Accelerator is supported for use in

Strany 57 - Index 57

Introduction 9 higher and VSL 3.x.x or higher is NOT data destructive. However, HP recommends that you back up any data on the device prior to perfo

Komentáře k této Příručce