HP Smart Array P430 Controller
User Guide
Abstract
This document includes feature, installation, and configuration information about HP Smart Array Controllers and is for the person who installs,
administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
Part Number: 742340-002
February 2014
Edition: 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - User Guide

HP Smart Array P430 Controller User Guide Abstract This document includes feature, installation, and configuration information about HP Smart Array

Strany 2

Specifications 10 Controller features Basic features This HP Smart Array controller has the following basic features: • Supports RAID 0, 1, 10, 1 (

Strany 3 - Contents

Specifications 11 compatible with HP key manager products and can operate with or without the presence of a key manager in the environment, dependin

Strany 4 - Contents 4

Specifications 12 Feature Description Duration of battery or capacitor pack backup 80 seconds The battery or capacitor pack provides a sufficient d

Strany 5 - Component identification

Installation and configuration 13 Installation and configuration Procedures for controllers in a server To install a stand-up controller in a server

Strany 6 - Controller LEDs

Installation and configuration 14 3. Verify the server firmware is the latest revision. If necessary, update the server firmware ("Updating fir

Strany 7 - Cache module LEDs

Installation and configuration 15 WARNING: To reduce the risk of personal injury or damage to the equipment, consult the safety information and us

Strany 8

Installation and configuration 16 o If the drives are hot-plug capable, connect the internal connector of the controller to the SAS connector on the

Strany 9 - Specifications

Installation and configuration 17 Configuration tools HP Smart Storage Administrator HP SSA is the main tool for configuring arrays on HP Smart Arra

Strany 10 - Controller features

Installation and configuration 18 UEFI System Utilities At this time, the HP ProLiant DL580 Gen8 Server is the only HP ProLiant Gen8 server that sup

Strany 11 - Controller specifications

Installation and configuration 19 2. Perform a normal system shutdown. 3. Restart the server. POST runs, and the system recognizes devices. When th

Strany 12

© Copyright 2013, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Strany 13

Installation and configuration 20 Configuring an array To configure an array on an HP Smart Array controller, use HP SSA. For more information, see

Strany 14

Installation and configuration 21 Managing servers with Insight Agents When using Insight Agents to manage HP ProLiant Gen8 servers, HP recommends t

Strany 15 - Connecting internal storage

Drive procedures 22 Drive procedures Identifying the status of an HP SmartDrive HP SmartDrives are the latest HP drive technology, and they are supp

Strany 16 - Cable part numbers

Drive procedures 23 Recognizing drive failure If any of the following occurs, the drive has failed: • The drive status LED illuminates amber. • Wh

Strany 17 - Configuration tools

Drive procedures 24 Compromised fault tolerance CAUTION: When fault tolerance is compromised, data loss can occur. However, it may be possible t

Strany 18 - Configuration procedures

Drive procedures 25 Before replacing drives • Open Systems Insight Manager, and inspect the Error Counter window for each physical drive in the sam

Strany 19 - UEFI mode boot options

Drive procedures 26 • Failure of a second drive in a RAID 6 configuration Time required for a rebuild The time required for a rebuild varies, depe

Strany 20 - System maintenance tools

Drive procedures 27 2. Restore data from backup. Writing data to the location of the unreadable sector often eliminates the error. 3. Remove and re

Strany 21 - Diagnostic tools

Drive procedures 28 When data rebuild on the new drive is complete, the Drive status LED changes from flashing green to solid green. 3. Repeat the

Strany 22 - Drive procedures

Drive procedures 29 o If a 1724 or 1727 POST message appears, drive positions were changed successfully and the configuration was updated. Continue

Strany 23 - Recognizing drive failure

Contents 3 Contents Component identification ...

Strany 24 - Replacing drives

Drive procedures 30 When the expansion process has finished, you can use the liberated storage capacity on the enlarged array to create new logical

Strany 25 - Before replacing drives

Electrostatic discharge 31 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strany 26 - Time required for a rebuild

Regulatory information 32 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strany 27 - Upgrading drive capacity

Regulatory information 33 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Strany 28 - Moving drives and arrays

Support and other resources 34 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strany 29 - Adding drives

Support and other resources 35 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strany 30 - Drive procedures 30

Support and other resources 36 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Strany 31 - Electrostatic discharge

Support and other resources 37 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Strany 32 - Regulatory information

Support and other resources 38 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strany 33 - Communications interference

Support and other resources 39 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strany 34 - Support and other resources

Contents 4 Adding drives ...

Strany 35

Support and other resources 40

Strany 36 - Customer Self Repair

Support and other resources 41

Strany 37

Acronyms and abbreviations 42 Acronyms and abbreviations ADM Advanced Data Mirroring CSR Customer Self Repair FBWC flash-backed write cache FCC F

Strany 38 - Reparo feito pelo cliente

Acronyms and abbreviations 43 SATA serial ATA SFF small form factor SMH System Management Homepage SPP HP Service Pack for ProLiant UEFI Unified

Strany 39

Documentation feedback 44 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Strany 40

Index 45 A adding drives 29 array, configuring 20 authorized reseller 34 automatic data recovery (rebuild) 25 B battery replacement notice

Strany 41

Index 46 J Japanese notice 32 L LEDs, cache module 7 LEDs, controller 6 limited warranty 33 load protection guarantee 33 M memory capacity

Strany 42 - Acronyms and abbreviations

Component identification 5 Component identification Controller components For cabling configuration and troubleshooting purposes, connector names ar

Strany 43 - HP Service Pack for ProLiant

Component identification 6 Controller LEDs Immediately after you power up the server, the controller runtime LEDs illuminate briefly in a predetermi

Strany 44 - Documentation feedback

Component identification 7 Item Color Name Interpretation 5 Amber Debug On = Controller is in reset state. Off = Controller is in an idle or ru

Strany 45 - Index 45

Component identification 8 1 - Amber 2 - Green 3 - Green Interpretation Off On On The cache module is idle, the battery or capacitor pack is cha

Strany 46 - Index 46

Specifications 9 Specifications Memory and storage capacity conventions Memory capacities are specified using binary prefixes: • KiB = 210 bytes •