Hp Smart Array P731m Controller Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačové příslušenství Hp Smart Array P731m Controller. HP Smart Array P731m Controller User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 45
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP Smart Array P731m Controller
User Guide
Abstract
This document includes feature, installation, and configuration information about HP Smart Array Controllers and is for the person who installs,
administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in
recognizing hazards in products with hazardous energy levels.
Part Number: 742335-002
February 2014
Edition: 2
Zobrazit stránku 0
1 2 3 4 5 6 ... 44 45

Shrnutí obsahu

Strany 1 - User Guide

HP Smart Array P731m Controller User Guide Abstract This document includes feature, installation, and configuration information about HP Smart Arra

Strany 2

Specifications 10 and the Cryptographic Module Validation Program on the National Institute of Standards and Technology website (http://csrc.nist.go

Strany 3 - Contents

Specifications 11 Feature Description Capacitor life expectancy More than 3 years Drives Supported drive types** • 3 and 6 Gb/s SAS • 3 and 6 Gb

Strany 4 - Contents 4

Installation and configuration 12 Installation and configuration Procedures for controllers in a server blade To install a mezzanine controller in a

Strany 5 - Component identification

Installation and configuration 13 15. (Optional) Create additional logical drives ("Configuring an array" on page 16). The server blade is

Strany 6 - FBWC module LEDs

Installation and configuration 14 19. If expanders are present, verify the expander firmware is the latest revision. If necessary, update the expand

Strany 7

Installation and configuration 15 The diagnostic features in HP SSA are also available in the standalone software HP Smart Storage Administrator Dia

Strany 8 - Specifications

Installation and configuration 16 After POST completes, the system launches the HP SSA GUI, or if you are using Serial Console, the system launches

Strany 9 - Controller features

Installation and configuration 17 Installing device drivers IMPORTANT: Always perform a backup before installing or updating device drivers. H

Strany 10 - Controller specifications

Installation and configuration 18 Smart Array controllers produce diagnostic error messages (POST messages) at reboot. Many POST messages suggest co

Strany 11 - 3 and 6 Gb/s SATA

Drive procedures 19 Drive procedures Identifying the status of a drive Identifying the status of a legacy drive Identify a legacy drive by its carri

Strany 12

© Copyright 2013, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Strany 13

Drive procedures 20 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing regularly (1 Hz) Amber, flashing regularly (1 Hz)

Strany 14 - Configuration tools

Drive procedures 21 Item LED Status Definition 4 Drive status Solid green The drive is a member of one or more logical drives. Flashing gree

Strany 15 - Configuration procedures

Drive procedures 22 Recognizing drive failure (HP SmartDrive) If any of the following occurs, the drive has failed: • The drive status LED illumina

Strany 16 - System maintenance tools

Drive procedures 23 Compromised fault tolerance CAUTION: When fault tolerance is compromised, data loss can occur. However, it may be possible t

Strany 17 - Diagnostic tools

Drive procedures 24 Before replacing drives • Open Systems Insight Manager, and inspect the Error Counter window for each physical drive in the sam

Strany 18

Drive procedures 25 • Failure of a second drive in a RAID 6 configuration Time required for a rebuild The time required for a rebuild varies, depe

Strany 19 - Drive procedures

Drive procedures 26 1. Back up as much data as possible from the logical drive. CAUTION: Do not remove the drive that has the media error. Doing

Strany 20

Drive procedures 27 2. Replace any drive. The data on the new drive is re-created from redundant information on the remaining drives. CAUTION: D

Strany 21 - Recognizing drive failure

Drive procedures 28 2. Power down the system. 3. Move the drives. 4. Power up the system. 5. Observe the POST messages: o If a 1785 POST message

Strany 22 - Drive procedures 22

Drive procedures 29 The expansion process is illustrated in the following figure, in which the original array (containing data) is shown with a dash

Strany 23 - Replacing drives

Contents 3 Contents Component identification ...

Strany 24 - Before replacing drives

Electrostatic discharge 30 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strany 25 - Time required for a rebuild

Regulatory information 31 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strany 26 - Upgrading drive capacity

Regulatory information 32 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20

Strany 27 - Moving drives and arrays

Support and other resources 33 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strany 28 - Adding drives

Support and other resources 34 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strany 29 - Drive procedures 29

Support and other resources 35 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Strany 30 - Electrostatic discharge

Support and other resources 36 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Strany 31 - Regulatory information

Support and other resources 37 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strany 32 - Communications interference

Support and other resources 38 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strany 33 - Support and other resources

Support and other resources 39

Strany 34

Contents 4 Upgrading drive capacity ...

Strany 35 - Customer Self Repair

Support and other resources 40

Strany 36

Acronyms and abbreviations 41 Acronyms and abbreviations ADM Advanced Data Mirroring CSR Customer Self Repair FBWC flash-backed write cache FCC F

Strany 37 - Reparo feito pelo cliente

Acronyms and abbreviations 42 SMH System Management Homepage SPP HP Service Pack for ProLiant

Strany 38

Documentation feedback 43 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Strany 39

Index 44 A adding drives 28 array, configuring 16 authorized reseller 33 automatic data recovery (rebuild) 24 B battery replacement notice

Strany 40

Index 45 L LEDs, controller 5 LEDs, drive 19 LEDs, FBWC module 6 limited warranty 32 load protection guarantee 32 M memory capacity conven

Strany 41 - Acronyms and abbreviations

Component identification 5 Component identification Controller components For cabling configuration and troubleshooting purposes, connector names ar

Strany 42 - HP Service Pack for ProLiant

Component identification 6 For this controller, the LEDs are typically used for debugging purposes and are not visible inside the server.

Strany 43 - Documentation feedback

Component identification 7 1 - Amber 2 - Green 3 - Green Interpretation Off Flashing once every 2 seconds Flashing once every 2 seconds The cache

Strany 44 - Index 44

Specifications 8 Specifications Memory and storage capacity conventions Memory capacities are specified using binary prefixes: • KiB = 210 bytes •

Strany 45 - Index 45

Specifications 9 Controller features Basic features This HP Smart Array controller has the following basic features: • Supports RAID 0, 1, 10, 1 (A

Komentáře k této Příručce

Žádné komentáře