Appendix A Specifications
90
Table A-2. Environmental Requirements
Parameter Conditions
Temperature
Operating
5
°
to 35
°
C (41
°
to 95
°
F)
Non-operating -40° to +65° C (-40° to +149° F)
Humidity
Operating 20% to 80% relative humidity,
non-condensing
Non-operating 5% to 95% relative humidity,
non-condensing
Altitude
Operating -30 to 3,000 m (~ 10,000 ft)
Non-operating -30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating
1007 BTU/hr
NOTE The specifications and requirements listed above can vary if
you install a mass storage device in the NetServer that has
more stringent environmental limits than required for the HP
NetServer. Ensure the operating environment for any mass
storage devices you intend to install are compatible with the
NetServer environmental requirements.
Table A-3. Weight and Dimensions
Weight
Approx. 30 lbs (14 kg.), depending on configuration
– excludes keyboard and monitor.
Height
17.09 inches (434 mm)
Width
7.1 inches (180mm)
11.67 inches (296.5mm) Feet opened
Depth
19.57 inches (497mm)