Component identification 9
Systems Insight Display LEDs and internal health LED
combinations
When the internal health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated system LEDs and the internal health LED indicate system
status.
Systems Insight Display
LED and color
Internal health
LED color
Status
Processor (amber) Red One or more of the following conditions may exist:
• Processor in socket X has failed.
• Processor X is not installed in the socket.
• Processor X is unsupported.
• ROM detects a failed processor during POST
Amber Processor in socket X is in a pre-failure condition.
DIMM (amber) Red DIMM in slot X has failed.
Amber DIMM in slot X is in a pre-failure condition.
DIMM (amber) Red One or more DIMMs have failed. Test each bank of
DIMMs by removing all other DIMMs. Isolate the failed
DIMM by replacing each DIMM in a bank with a known
working DIMM.
Overtemperature (amber) Amber The Health Driver has detected a cautionary temperature
level.
Red The server has detected a hardware critical temperature
level.
Fan (amber) Amber One fan is failed or removed.
Red Two or more fans have failed or are missing.
Power supply (amber) Red Only one power supply installed and power supply in
standby.
• Power supply fault
• System board fault
Power supply (amber) Amber Redundant power supply installed and only one power
supply is functional.
• AC power cord not plugged into redundant power
supply
• Redundant power supply fault
Power supply (amber) Amber Power supply mismatch at POST or power supply mismatch
through hot add.