Hp ProLiant DL760 G2 Server Uživatelský manuál Strana 283

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 299
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 282
Troubleshooting Information
Table E-7: Are either of the Processor Board attention LED’s located on the front
bezel illuminated?
Status Action
Processor board 1 attention LED is illuminated
and processor board 2 is not installed.
Check interconnect LEDs on the I/O lid to
see if board is seated.
If processors were just added, be sure that
all processors on the board are the same
cache size and speed.
Check connector for bent pins.
Processor board 1 attention LED is illuminated
and processor board 2 is installed.
Check interconnect LEDs on the I/O lid to
see if board is seated.
If processors were just added, be sure that
all processors on the board are the same
cache size and speed.
Check connector for bent pins.
If video is available, look for additional
information contained within the POST
error messages.
Processor board 2 attention LED is illuminated
and processor board 1 is not installed.
Move processor board to slot 1 and retry
applying power.
continued
HP ProLiant DL760 Generation 2 Server User Guide E-15
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: o-appe Troubleshooting Information.doc
Codename: Pioneer Part Number: 201264-002 Last Saved On: 6/17/03 10:42 AM
Zobrazit stránku 282