Hp ProLiant DL760 G2 Server Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Hp ProLiant DL760 G2 Server. HP ProLiant DL760 G2 Server User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 299
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

HP ProLiant DL760 Generation 2 Server User Guide June 2003 (Second Edition) Part Number 201264-002 HP CONFIDENTIAL Writer: Jennifer Hayward Fi

Strany 2

About This Guide This guide provides step-by-step installation instructions and reference information for operating, troubleshooting, and upgrading

Strany 3 - Contents

Installing Hardware Options, Server Power Off 3. Insert the PCI/PCI-X expansion board into the appropriate expansion slot (1), pushing firmly until t

Strany 4

Installing Hardware Options, Server Power Off 5. Connect the expansion board I/O cable as appropriate. HP has designed a self-latching slot-keeper fe

Strany 5

Installing Hardware Options, Server Power Off Installing the Remote Insight Lights-Out Edition II The ProLiant DL760 G2 server supports the Remote Ins

Strany 6

Installing Hardware Options, Server Power Off 7. HP recommends installing the RILOE II board in I/O expansion slot 9 for easy access to the Remote Ma

Strany 7

Installing Hardware Options, Server Power Off 10. Insert the RILOE II board into slot 9 (1), pushing firmly until the board is securely seated. 11.

Strany 8

Installing Hardware Options, Server Power Off 14. Route the Remote Management cable (30-pin) under the fan support bracket and connect it to the Remo

Strany 9

Installing Hardware Options, Server Power Off RILOE II can use either system power or external power. External power may be required for the RILOE II

Strany 10 - About This Guide

Installing Hardware Options, Server Power Off Installing the Integrated Array Bypass Use the Integrated Array Bypass kit to bypass the Smart Array 5i

Strany 11

Installing Hardware Options, Server Power Off 7. Remove any I/O expansion boards from slots 1 through 5. a. For full-length I/O expansion boards, be

Strany 12 - Symbols in Text

Installing Hardware Options, Server Power Off b. Press the top of the appropriate expansion slot release lever (1) and open the lever toward the rear

Strany 13 - Hood Labels and Indicators

About This Guide This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personn

Strany 14 - Related Documents

Installing Hardware Options, Server Power Off 8. Remove the four plastic slot dividers from between slots 1 through 5. Push the divider clip down to

Strany 15 - HP Website

Installing Hardware Options, Server Power Off 9. Lift the locking lever to release the Array Enabler board (1). Remove the Array Enabler board (2) as

Strany 16 - Authorized Reseller

Installing Hardware Options, Server Power Off 10. Install the Integrated Array Bypass assembly. IMPORTANT: The Integrated Array Bypass assembly cab

Strany 17 - [email protected]

Installing Hardware Options, Server Power Off 11. Reinstall the plastic slot dividers and any I/O expansion boards that were removed. 12. Press the

Strany 18 - Server Features

Installing Hardware Options, Server Power Off 14. Install the optional array controller board (1) as shown in Figure 4-20. 15. Close the expansion s

Strany 19 - Overview

Installing Hardware Options, Server Power Off 4-26 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File N

Strany 20

5 Installing Hardware Options, Hot-Pluggable The following instructions are provided as an overview for installing hardware option upgrades that are

Strany 21

Installing Hardware Options, Hot-Pluggable Hot Plug RAID Memory The ProLiant DL760 G2 server supports up to 40 GB of Hot Plug RAID Memory using indust

Strany 22

Installing Hardware Options, Hot-Pluggable Memory Cartridge Components The following figure and table show the various components of the memory cartri

Strany 23

Installing Hardware Options, Hot-Pluggable Memory Cartridge Guidelines The ProLiant DL760 G2 server has five Hot Plug RAID Memory cartridges. They are

Strany 24 - Processors

About This Guide Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are

Strany 25

Installing Hardware Options, Hot-Pluggable The following additional guidelines apply to DIMM installation: • DIMM configurations must match in all fi

Strany 26 - Hot Plug RAID Memory

Installing Hardware Options, Hot-Pluggable Memory Cartridge LED Indicators The ProLiant DL760 G2 server has LEDs for each of the memory cartridges. Th

Strany 27

Installing Hardware Options, Hot-Pluggable LED Indicator State Definitions Table 5-2 provides descriptions of various LED states. Table 5-2: Memory

Strany 28 - PCI-X Technology

Installing Hardware Options, Hot-Pluggable Accessing the DIMMs To access the DIMMs in the server, you must remove the memory cartridge. The Hot Plug R

Strany 29 - Network Interface Controller

Installing Hardware Options, Hot-Pluggable 2. Be sure that the cartridge power LED is off (2). CAUTION: Do not remove a memory cartridge if the ca

Strany 30 - Internal Hot-Plug Drive Bays

Installing Hardware Options, Hot-Pluggable Opening the Memory Cartridge To gain access to the DIMMs, open the memory cartridge cover: 1. Squeeze the

Strany 31

Installing Hardware Options, Hot-Pluggable Locating the DIMM Sockets Figure 5-6 and Table 5-3 detail the DIMM socket locations on the memory cartridge

Strany 32 - Supported Interfaces

Installing Hardware Options, Hot-Pluggable SDRAM Bus Configuration Figure 5-7 detail the SDRAM memory bus configuration. Bank definition ensures that

Strany 33 - Supported Operating Systems

Installing Hardware Options, Hot-Pluggable Installing DIMMs into the Memory Cartridge CAUTION: When handling a memory module, be careful not to tou

Strany 34 - SmartStart

Installing Hardware Options, Hot-Pluggable 3. Be sure that all of the DIMM socket levers are rotated inward before closing the cartridge cover. 4. C

Strany 35

About This Guide Hood Labels and Indicators A significant amount of server configuration and options installation information is provided on the panel

Strany 36 - Advanced Data Guarding

Installing Hardware Options, Hot-Pluggable • SCO UnixWare 7.1.3 • Red Hat Linux 7.2 • SuSE Linux Enterprise Server 7 Hot-Replacing Memory If there

Strany 37

Installing Hardware Options, Hot-Pluggable To replace DIMMs: 1. Unlock the cartridge and slide it out of the server following the procedure in the “R

Strany 38 - HP Utilities for Linux

Installing Hardware Options, Hot-Pluggable Hot-Adding Memory For the hot-add feature to work on the ProLiant DL760 G2 server, the operating system mus

Strany 39

Installing Hardware Options, Hot-Pluggable To install additional DIMMs in the server, you must add them in bank pairs across all five of the memory ca

Strany 40

Installing Hardware Options, Hot-Pluggable f. The system will rebuild and verify the data on the DIMMs in the memory cartridge as the cartridge power

Strany 41 - Diagnostic Tools

Installing Hardware Options, Hot-Pluggable Hot-Upgrading Memory For the hot-upgrade feature to work on the ProLiant DL760 G2 server, the operating sys

Strany 42 - Software Security

Installing Hardware Options, Hot-Pluggable To upgrade memory, replace existing DIMMs with new ones in bank pairs across all five of the memory cartrid

Strany 43 - Hardware Security

Installing Hardware Options, Hot-Pluggable f. Lock the memory cartridge in place by rotating the cartridge lock clockwise to the locked position. g.

Strany 44 - Warranty

Installing Hardware Options, Hot-Pluggable Non-RAID Memory Support Non-RAID memory configuration is now more user-friendly in the ProLiant DL760 Gener

Strany 45

Installing Hardware Options, Hot-Pluggable Installing Hot-Plug Hard Drives The following sections provide an overview for installing hot-plug SCSI har

Strany 46 - Rack Installation Overview

About This Guide Related Documents For additional information on the topics covered in this guide, refer to the following documentation: • Rack Resou

Strany 47 - Selecting a Site

Installing Hardware Options, Hot-Pluggable The following illustration shows the media module populated with four 1-inch hard drives, an IMD, a diskett

Strany 48 - Power Requirements

Installing Hardware Options, Hot-Pluggable Hot-Plug SCSI Hard Drive LED Indicators The hot-plug SCSI hard drive LEDs, located on each physical drive,

Strany 49

Installing Hardware Options, Hot-Pluggable Figure 5-11: SCSI hard drive LEDs HP ProLiant DL760 Generation 2 Server User Guide 5-27 HP CONFIDENTIA

Strany 50

Installing Hardware Options, Hot-Pluggable Guidelines for Installing Hot-Plug SCSI Hard Drives Follow these guidelines when adding SCSI hard drives: •

Strany 51 - Grounding Requirements

Installing Hardware Options, Hot-Pluggable Installing a Hot-Plug SCSI Hard Disk Drive CAUTION: Before adding or removing any hot-plug SCSI drives,

Strany 52 - Temperature Requirements

Installing Hardware Options, Hot-Pluggable 3. Insert the new hot-plug drive into the empty drive bay, pushing until the unit is securely seated (1).

Strany 53 - Shipping Box Contents

Installing Hardware Options, Hot-Pluggable Advanced Data Guarding When a disk drive is hot-plugged, although the system is functionally operational, t

Strany 54 - Shipping Brackets

Installing Hardware Options, Hot-Pluggable • Never turn a disk enclosure off while the initiator or controller is powered on or active. Doing so can

Strany 55

Installing Hardware Options, Hot-Pluggable Installing a StorageWorks Hot-Plug Tape Drive To install a StorageWorks hot-plug tape drive into the drive

Strany 56 - Figure 2-4: Shipping screws

Installing Hardware Options, Hot-Pluggable Installing a Hot-Plug Power Supply The ProLiant DL760 G2 server ships with two hot-plug power supplies. The

Strany 57 - Security Screw

About This Guide Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help i

Strany 58

Installing Hardware Options, Hot-Pluggable To replace a hot-plug power supply with the system power on: 1. Remove the power cord from the power suppl

Strany 59

Installing Hardware Options, Hot-Pluggable 2. Squeeze upward on the release in the middle of the power supply handle (1). 3. Rotate the power supply

Strany 60 - Warnings and Precautions

Installing Hardware Options, Hot-Pluggable 6. Slide the hot-plug power supply into the power supply cage until the supply is seated securely (1). Thi

Strany 61

Installing Hardware Options, Hot-Pluggable 8. Plug in the power cord. You can use the plastic clip to secure the AC cord to the power supply. This ac

Strany 62

Installing Hardware Options, Hot-Pluggable Power Supply LED Indicators Each power supply has status and AC power LEDs. Refer to Figure 5-19 and Table

Strany 63

Installing Hardware Options, Hot-Pluggable PCI Hot Plug I/O Expansion Boards The ProLiant DL760 G2 server supports PCI Hot Plug. PCI Hot Plug and the

Strany 64

Installing Hardware Options, Hot-Pluggable Locating the I/O Expansion Slots The I/O expansion slots are located in the I/O module and are accessed by

Strany 65

Installing Hardware Options, Hot-Pluggable Table 5-5: I/O Expansion Slots Slot Description Slots 1 and 2 Bus 19—Supports PCI-X expansion boards at

Strany 66

Installing Hardware Options, Hot-Pluggable PCI Hot Plug LED Indicators The PCI Hot Plug amber (1) and green (2) LEDs (shown in the following figure fo

Strany 67

Installing Hardware Options, Hot-Pluggable Table 5-6 provides a description and slot status for the PCI Hot Plug LEDs and button shown in Figure 5-22.

Strany 68 - Lightening the Chassis

About This Guide Authorized Reseller For the name of your nearest authorized reseller: • In the United States, call 1-800-345-1518. • In Canada, cal

Strany 69

Installing Hardware Options, Hot-Pluggable PCI Hot Plug Operating System Support Software support is an integral part of PCI Hot Plug. HP, in partners

Strany 70

Installing Hardware Options, Hot-Pluggable Microsoft Windows 2000 Supported PCI Hot Plug Functionality PCI Hot Plug support within Microsoft Windows 2

Strany 71

Installing Hardware Options, Hot-Pluggable Microsoft Windows Server 2003 Supported PCI Hot Plug Functionality PCI Hot Plug support within Microsoft Wi

Strany 72

Installing Hardware Options, Hot-Pluggable SCO/Caldera UnixWare Supported PCI Hot Plug Functionality HP support of PCI Hot Plug within Caldera Open UN

Strany 73

Installing Hardware Options, Hot-Pluggable The device driver interface specification defines how device drivers communicate with the SCO UnixWare oper

Strany 74

Installing Hardware Options, Hot-Pluggable Adding PCI Hot Plug Expansion Boards The PCI/PCI-X slots of the ProLiant DL760 G2 I/O board are hot-plug-ca

Strany 75 - 10. Cable the server

Installing Hardware Options, Hot-Pluggable 4. Press the top (1) of the appropriate expansion slot release lever and open the lever toward the rear (2

Strany 76

Installing Hardware Options, Hot-Pluggable 6. Insert the PCI/PCI-X expansion board into the appropriate expansion slot, pushing firmly until the boar

Strany 77 - Server Access

Installing Hardware Options, Hot-Pluggable HP has designed a self-latching slot-keeper feature to accommodate full-length expansion boards. Be sure th

Strany 78 - Access Method

Installing Hardware Options, Hot-Pluggable 9. Activate power to the slot through the PCI Hot Plug software application or by pressing the PCI Hot Plu

Strany 79 - Accessing the I/O Module

About This Guide The optional hardware installation service is available in all countries where HP has a direct or indirect service presence. Service

Strany 80 - Removing the I/O Module

Installing Hardware Options, Hot-Pluggable Removing or Replacing a PCI Hot Plug Expansion Board To remove or replace a PCI Hot Plug expansion board: 1

Strany 81

Installing Hardware Options, Hot-Pluggable 4. Press the top (1) of the appropriate expansion slot release lever and open the lever toward the rear (2

Strany 82

Installing Hardware Options, Hot-Pluggable Replacing Hot-Plug Fans The ProLiant DL760 G2 server ships with two hot-plug fans. Fan 1 is closest to the

Strany 83

Installing Hardware Options, Hot-Pluggable The ProLiant DL760 G2 server comes equipped with fan attention LEDs located on the front of the server as s

Strany 84

Installing Hardware Options, Hot-Pluggable To replace a hot-plug fan: 1. Open the I/O lid. 2. Squeeze the locking latch with your fingers (1), and l

Strany 85

Installing Hardware Options, Hot-Pluggable 5-60 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Bryce Miller File Name: f-

Strany 86 - Removing the Media Module

6 Cabling the Server This chapter provides information about how to cable a ProLiant DL760 G2 server. HP ProLiant DL760 Generation 2 Server User Gui

Strany 87

Cabling the Server Cable Connectors Figure 6-1 identifies the peripheral connectors on the back of the server. Figure 6-1: Rear panel connectors It

Strany 88 - 7. Connect all power cords

Cabling the Server WARNING: To reduce the risk of electric shock or damage to the equipment: • Install the power supply before connecting the power

Strany 89 - Media Module Components

Cabling the Server 2. Secure the AC cord with the retention clip provided on the power supply, as shown in the following figure, to prevent the cord

Strany 90

1 Server Features HP ProLiant DL760 Generation 2 Servers The HP ProLiant DL760 Generation 2 (G2) server, a high-density enterprise-class and data cen

Strany 91 - Intel Xeon Processor MP

Cabling the Server HP ProLiant DL760 Generation 2 Server User Guide 6-5 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: g-ch6 Cabling the Serve

Strany 92 - Installing a Processor Board

7 Server Power This chapter provides information about the operation of the server power supplies. The purpose of this chapter is to guide you throug

Strany 93

Server Power System Power Overview The system power in the ProLiant DL760 G2 server does not shut off completely with the front panel Power On/Standby

Strany 94

Server Power Power Supplies The ProLiant DL760 G2 server supports two hot-plug, redundant power supplies. Refer to Chapter 5 to replace a power supply

Strany 95

Server Power Power Supply LED Indicators Each power supply has status and AC power LEDs. Refer to Figure 7-2 and Table 7-1 for a detailed description

Strany 96 - Non-Hot-Plug I/O Expansion

Server Power System Interconnect Status Indicators To prevent damage to critical system components, the ProLiant DL760 G2 server will not power up if

Strany 97

Server Power If an interconnect status indicator light is on, reseat the component represented by the indicator. Refer to Appendix D for detailed LED

Strany 98

Server Power Powering Up the Server When you power up the server, it will go through the following “Server Power” and “Power-On Self-Test” sequences.

Strany 99 - To add an expansion board:

Server Power 2. Check the system power LED: 7-8 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Nam

Strany 100 - HP CONFIDENTIAL

Server Power 7. Watch for memory system initialization. As the system initializes, the memory cartridge power LEDs on all five memory cartridges begi

Strany 101

Server Features Overview This chapter provides an overview of the HP ProLiant DL760 G2 server features and briefly describes its maximum performance,

Strany 102

Server Power 6. Check the monitor for ROM family and date. The system briefly displays the F1 prompt to open the Memory Configuration Manager. Figur

Strany 103

Server Power Press the F1 key to enter the Memory Configuration Manager. This ROM-Based tool (shown in Figure 7-7) is used to examine and upgrade your

Strany 104

Server Power 7. Check the monitor for processor initialization information. Each processor is listed as it initializes. 8. Check the monitor for con

Strany 105 - Management cable (30-pin)

Server Power HP ProLiant DL760 Generation 2 Server User Guide 7-13 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: h-ch7 Server Power.doc Coden

Strany 106

8 Configuring the Server This chapter discusses how to configure the ProLiant DL760 G2 server by setting up the server environment, setting up the ha

Strany 107

Configuring the Server Setting Up the Base Environment The ProLiant DL760 G2 comes equipped with updateable, “intelligent” ROM-based configuration uti

Strany 108

Configuring the Server If the system memory is installed in an unsupported configuration, then the Memory Configuration Error Diagnostics screen is di

Strany 109

Configuring the Server Manual Configuration Pressing the F9 key when prompted during POST launches RBSU, from which you are guided through the followi

Strany 110

Configuring the Server 2. Set the operating system of the server. Figure 8-4: Setting the operating system in RBSU 3. After the language and opera

Strany 111

Configuring the Server Accessing the System Maintenance Menu The System Maintenance Menu is embedded into the system ROM and replaces the legacy Syste

Strany 112

© 2002, 2003 Hewlett-Packard Development Group, L.P. Microsoft®, Windows®, and Windows NT® are US registered trademarks of Microsoft Corporation. Int

Strany 113

Server Features The ProLiant DL760 G2 server also features management and configuration tools that are the hallmark of ProLiant servers: • ProLiant E

Strany 114

Configuring the Server Figure 8-6: System prompts after normal POST HP ProLiant DL760 Generation 2 Server User Guide 8-7 HP CONFIDENTIAL Writer:

Strany 115

Configuring the Server System Maintenance Menu After you press the F10 key at the end of POST, the System Maintenance Menu screen is displayed, as sho

Strany 116

Configuring the Server ROM-Based Setup Utility When you select Setup Utility in the System Maintenance Menu, the system will execute RBSU. The main RB

Strany 117 - Memory Cartridge Overview

Configuring the Server ROM-Based Inspect Utility When you select Inspect Utility in the System Maintenance Menu, the system executes the ROM-Based Ins

Strany 118 - Memory Cartridge Components

Configuring the Server ROM-Based Diagnostic Utility When you select Diagnostic Utility in the System Maintenance Menu, the system executes the ROM-Bas

Strany 119 - Memory Cartridge Guidelines

Configuring the Server Memory Diagnostics When you select Memory Diagnostic from the ROM-Based Diagnostic Utility menu, the diagnostic runs until comp

Strany 120

Configuring the Server CPU Diagnostic The CPU diagnostic checks the registers and multiprocessing capability of each of the system processors. The CPU

Strany 121

Configuring the Server Boot Disk Diagnostic The boot disk diagnostic can be used to verify the presence and readiness of a primary boot controller. If

Strany 122

Configuring the Server Configuring the Drive Array Controller If you are using a simple SCSI controller to boot from the internal drives, disregard th

Strany 123 - Accessing the DIMMs

Configuring the Server The location of the external SCSI connector (1) is shown in the following figure. Figure 8-14: External VHDCI SCSI Connector

Strany 124

Server Features Figure 1-1: Server front view—module location Item Description 1 Processor and memory module 2 Media module 1-4 HP ProLiant DL760

Strany 125 - DIMM Overview

Configuring the Server Option ROM Configuration for Arrays After the POST sequence successfully concludes, the server executes the option ROMs. An opt

Strany 126 - Locating the DIMM Sockets

Configuring the Server Accessing ORCA After the system has completed POST, press the F8 key for custom configuration or the F7 key to accept the defau

Strany 127 - SDRAM Bus Configuration

Configuring the Server Using ORCA To configure the drive array controller: CAUTION: If you have installed any previously used hard drives in the Pr

Strany 128

Configuring the Server Array Configuration Utility The Array Configuration Utility (ACU) is an easy-to-use graphical configuration utility to help set

Strany 129

Configuring the Server Starting the Array Configuration Utility The ACU software can be run from CD or from within supported operating systems. Runnin

Strany 130 - Hot-Replacing Memory

Configuring the Server Running ACU from the Operating System If the server that you are configuring is running in Windows 2000, Windows Server 2003, o

Strany 131

Configuring the Server Extending Logical Drives — Operating Systems The following operating systems support logical drive extension: • Microsoft Wind

Strany 132 - Hot-Adding Memory

Configuring the Server Array Configuration Replicator Utility The Array Configuration Replicator (ACR) utility enables you to configure Smart Array co

Strany 133

Configuring the Server Installing the Operating System If you are installing the operating system using the SmartStart CD, configure it by using the i

Strany 134

Configuring the Server 8-26 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: i-ch8 Configuring

Strany 135 - Hot-Upgrading Memory

Server Features Figure 1-2: Server front view—module components Item Description 1 Processor area and air intake 2 Hot-plug hard drives 3 IDE CD-

Strany 136

9 Software Management HP provides several tools that aid in managing and maintaining the ProLiant DL760 G2 server: • Integrated Management Display (

Strany 137

Software Management Integrated Management Display The Integrated Management Display (IMD) is an integrated 16x4 character display mounted on the front

Strany 138 - Non-RAID Memory Support

Software Management To run the RBSU: 1. Boot the computer and at the prompt press the F9 key. 2. Select Server Asset & IMD Text and press the En

Strany 139

Software Management 8. Press the F10 key at the prompt to confirm the exit from RBSU. The changes you have entered will not be displayed on the Displ

Strany 140

Software Management Customizing Management Display Fields You can customize many of the fields shown on the IMD. The following sections define each of

Strany 141

Software Management Custom Menu Item Custom Menu Item is a user-defined field for customizing a server. This one-line field can hold up to 14 characte

Strany 142

Software Management Server Other Enter any additional information about the server that might be helpful. You can enter up to 2 lines of 14 characters

Strany 143

Software Management Service Contact Phone Number The Service Contact Phone Number field contains the phone number of the service provider. Enter up to

Strany 144

Software Management Bootblock Date The Bootblock Date is the month, date, and year of the current server Bootblock. Memory The Memory field shows the

Strany 145

Software Management Navigating the Menus The IMD is menu-driven and designed to be easy to use. The following sections provide information about how t

Strany 146

Server Features Figure 1-3: Server rear view—module location Item Description 1 I/O module with system fans 2 Hot-plug power supply #1 3 Hot-plug

Strany 147

Software Management Display Symbols Three display symbols enable you to indicate your menu options. These symbols are the Up, Down, and Selector arrow

Strany 148

Software Management Navigation To navigate through the menus, use the four buttons shown in the following figure. The up (3) and down (2) arrow keys a

Strany 149

Software Management System Behavior with Error Events If there is an F1 error condition after system POST, the IMD flashes the message in Figure 9-4.

Strany 150

Software Management Menu Structure The following outline shows the four elements of each IMD menu and submenu in the order in which they are displayed

Strany 151

Software Management System Information • ROM • Bootblock Date • Memory • PCI Slot • System Processor Contrast • Contrast Other Info Integrated M

Strany 152

Software Management Multiple Ways of Viewing the Integrated Management Log You can view an event in the IML in one of three ways: • From the IMD • F

Strany 153

Software Management Viewing the IML with the Survey Utility The Survey Utility is an online information-gathering agent that runs on servers, gatherin

Strany 154 - Power Supply LED Indicators

Software Management Viewing the IML with Insight Manager 7 Insight Manager 7 is a server management tool capable of in-depth fault, configuration, and

Strany 155

Software Management Figure 9-6: Integrated Management Log 4. If a failed component has been replaced, select the event from the list, then click Ma

Strany 156

Software Management Insight Manager 7 Insight Manager 7 is a server management tool capable of in-depth fault, configuration, and performance monitori

Strany 157

Server Features Standard Features The following additional features are available on ProLiant DL760 G2 server models. Processors The server supports f

Strany 158 - PCI Hot Plug LED Indicators

Software Management HP ProLiant DL760 Generation 2 Server User Guide 9-21 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: j-ch9 Software Manage

Strany 159

Software Management Array Configuration Utility The Array Configuration Utility (ACU) software for Smart Array controllers, the StorageWorks RAID Arra

Strany 160

Software Management Step 2—Running ACU as a Service With Remote Accessibility During installation (or later by running setup), choose to install ACU a

Strany 161

Software Management 9-24 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: j-ch9 Software Manage

Strany 162

A Regulatory Compliance Notices Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identificati

Strany 163

Regulatory Compliance Notices Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class

Strany 164

Regulatory Compliance Notices Canadian Notice (Avis Canadien) This Class A digital apparatus meets all requirements of the Canadian Interference-Causi

Strany 165

Regulatory Compliance Notices Japanese Notice BSMI Notice A-4 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer H

Strany 166

Regulatory Compliance Notices Laser Devices All HP systems equipped with a laser device comply with safety standards, including International Electrot

Strany 167

Regulatory Compliance Notices Power Cords The power cord set included in your server meets the requirements for use in the country where you purchased

Strany 168

Server Features Hyper-Threading technology, developed by Intel, improves the performance of IA-32 processors when executing multiple-processor (MP) ca

Strany 169

Regulatory Compliance Notices HP ProLiant DL760 Generation 2 Server User Guide A-7 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: k-appa Regul

Strany 170 - Expansion Board

B Electrostatic Discharge To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling part

Strany 171

Electrostatic Discharge B-2 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: l-appb Electrostat

Strany 172 - Replacing Hot-Plug Fans

C Server Error Messages POST Error Messages All Power-On Self-Test (POST) error messages provided for this server are included in the HP Servers Trou

Strany 173

D LED Indicators and Switches LED Indicators Status LEDs are located on the front, back, and inside of your server. These LEDs communicate the curren

Strany 174 - 1. Open the I/O lid

LED Indicators and Switches System Power LED Indicator Figure D-1 shows the location of the system power LED (1). Figure D-1: System power LED D-2

Strany 175

LED Indicators and Switches Auxiliary Power LED Indicator Figure D-2 shows the location of the auxiliary power LED (1) on the I/O board. Figure D-2:

Strany 176 - Cabling the Server

LED Indicators and Switches System Interconnect LED Indicators To prevent damage to critical system components, the ProLiant DL760 G2 server will not

Strany 177 - Cable Connectors

LED Indicators and Switches If a status indicator light is on, reseat the component represented by the indicator. Refer to the hood labels for compone

Strany 178

LED Indicators and Switches System Attention LED Indicators Figure D-5 shows the location of the system attention LEDs. Figure D-5: System attention

Strany 179

Server Features Hot Plug RAID Memory The HP memory RAID technology stands for Redundant Array of Industry-Standard DIMMs. The ProLiant DL760 G2 server

Strany 180

LED Indicators and Switches Hot-Plug SCSI Hard Drive LED Indicators The hot-plug SCSI hard drive LEDs, located on each physical drive, are visible on

Strany 181 - Server Power

LED Indicators and Switches Figure D-7: SCSI hard drive LEDs D-8 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennife

Strany 182 - System Power Overview

LED Indicators and Switches Power Supply LED Indicators Each power supply has status and AC power LEDs. Refer to Figure D-8 and Table D-1 for a detail

Strany 183 - Power Supplies

LED Indicators and Switches Hot-Plug Fan LED Indicators The ProLiant DL760 G2 server ships with two hot-plug fans. Fan 1 is closest to the rear of the

Strany 184

LED Indicators and Switches PCI Hot Plug LED Indicators The PCI Hot Plug amber (1) and green (2) LEDs (shown in the following figure for one slot) pro

Strany 185

LED Indicators and Switches A description and slot status for the PCI Hot Plug LEDs and button as shown in Figure D-11 are provided in Table D-2. Tab

Strany 186

LED Indicators and Switches Memory Cartridge and DIMM Status LED Indicators The ProLiant DL760 G2 server has LEDs for each of the memory cartridges. T

Strany 187

LED Indicators and Switches LED Indicator State Definitions Table D-4 provides descriptions of various LED states of the memory cartridge LEDs. Table

Strany 188

LED Indicators and Switches Switches This section shows switch location and settings for the I/O board. I/O Board Configuration Switches The I/O board

Strany 189 - Power-On Self-Test

E Troubleshooting Information This appendix provides step-by-step instructions about what to try and where to go for help for the most common problem

Strany 190

Server Features The ProLiant DL760 G2 server has eight memory banks, each consisting of five DIMMs installed across the five memory cartridges. In eac

Strany 191

Troubleshooting Information Server Startup Problems Complete these steps if the server does not start: 1. Be sure that the computer and monitor are p

Strany 192 - Figure 7-8: System prompts

Troubleshooting Information HP ProLiant DL760 Generation 2 Server User Guide E-3 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: o-appe Troubl

Strany 193 - Powering Down the Server

Troubleshooting Information Diagnosis Steps If your server does not power up or powers up but does not complete the POST, answer the questions in the

Strany 194 - Configuring the Server

Troubleshooting Information Table E-1: Diagnosis Steps continued Question Action Question 7: Check the Memory Error and Processor Bus Fault LEDs. Are

Strany 195

Troubleshooting Information Figure E-2: Memory Configuration Manager E-6 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer:

Strany 196

Troubleshooting Information Table E-2: Did Power Supply Turn On? Check to see if the power supply and system fans are running. Verify this visually.

Strany 197 - Manual Configuration

Troubleshooting Information Table E-3: Did the System Power LED Indicator or the Interconnect Check Light on the Front Panel Turn On? Refer to “Syst

Strany 198

Troubleshooting Information Table E-3: Did the System Power LED Indicator or the Interconnect Check Light on the Front Panel Turn On? continued Refer

Strany 199

Troubleshooting Information Table E-4: Is the Auxiliary Power LED Indicator On? Refer to “Auxiliary Power LED Indicator” in Appendix D for the locat

Strany 200

Troubleshooting Information Table E-4: Is the Auxiliary Power LED Indicator On? continued Refer to “Auxiliary Power LED Indicator” in Appendix D for

Strany 201 - System Maintenance Menu

Server Features PCI-X Technology PCI-X technology leverages the wide acceptance of the PCI bus and provides an evolutionary I/O upgrade to conventiona

Strany 202 - ROM-Based Setup Utility

Troubleshooting Information Table E-5: Are all of the System Interconnect Status LED Indicators Off? Refer to “System Interconnect LED Indicators” i

Strany 203 - ROM-Based Inspect Utility

Troubleshooting Information Table E-5: Are all of the System Interconnect Status LED Indicators Off? continued Refer to “System Interconnect LED Indi

Strany 204 - ROM-Based Diagnostic Utility

Troubleshooting Information Table E-6: Is the IMD On or Does the Server Have Video? Answer Possible Reasons The Next Step Yes Video is availabl

Strany 205

Troubleshooting Information Table E-7: Are either of the Processor Board attention LED’s located on the front bezel illuminated? Status Action Proce

Strany 206 - Figure 8-12: CPU diagnostic

Troubleshooting Information Table E-7: Are either of the Processor Board attention LED’s located on the front bezel illuminated? continued Status Act

Strany 207

Troubleshooting Information Table E-8: Memory Configuration Guidelines Problem Possible Cause Possible Solution Missing memory cartridge Install al

Strany 208

Troubleshooting Information Table E-9: Problems After Initial Boot Problem Possible Cause Possible Solution SmartStart requirement is not performed.

Strany 209

Troubleshooting Information Table E-9: Problems After Initial Boot continued Problem Possible Cause Possible Solution Required operating system step

Strany 210

Troubleshooting Information E-20 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: o-appe Troubl

Strany 211 - Figure 8-15: ORCA main menu

F Server Specifications Server Specifications Table F-1: ProLiant DL760 G2 Server Specifications Dimensions Height 12.0 in 30.5 cm Depth 27.0

Strany 212

Server Features PCI Hot Plug PCI Hot Plug provides the ability to remove, replace, upgrade, and add PCI/PCI-X expansion boards without powering down

Strany 213 - Array Configuration Utility

G System Battery This appendix provides information about replacement of the ProLiant DL760 G2 server system battery. Internal Battery To remove the

Strany 214

System Battery G-2 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: q-appg System Battery.doc C

Strany 215

HP ProLiant DL760 Generation 2 Server User Guide Index-1 COMPAQ CONFIDENTIAL Writer: Jennifer Hayward File Name: x-index.doc Codename: Pioneer Par

Strany 216

Index RBSU features 1-18 setting up server environment 8-2 system load 2-6 configuration tools 1-3 connectors, supported 1-15 controllers

Strany 217

Index H hard drives fault protection 1-19 installing 5-24 LED indicators 5-26, D-7 location 1-5, 3-13 supported 1-13 VHDCI connector 8-15

Strany 218

Index rack rail assemblies 2-22 RILOE II 4-13 storage devices 5-24 tape drive 5-33 Integrated Array Bypass kit 4-18 Integrated Management Di

Strany 219

Index LED indicators 5-6 location 5-2 removal 5-8 Memory Diagnostic option 8-12 Microsoft Windows PCI Hot Plug support 5-46 running ACU from

Strany 220 - Software Management

Index processor and memory module accessing 3-2 identifying components 3-9 installing memory 5-2 removing 3-6 processor board air baffle 4-4

Strany 221 - CD for more information

Index SCO/Caldera UNIX PCI Hot Plug support 5-48 utilities for 1-20 SCSI devices, installing 4-6. See also hard drives SDRAM bus configuration

Strany 222

Index utilities ACR 8-24 ACU 8-20 Boot Disk Diagnostic 8-11 CPU Diagnostic 8-11 IMD 9-4 installing 8-26 Memory Diagnostic 8-11 operating

Strany 223

HP ProLiant DL760 Generation 2 Server User Guide iii HP CONFIDENTIAL Writer: Jennifer Hayward File Name: a-frnt.doc Codename: Pioneer Part Number:

Strany 224 - IN SALES 2002

Server Features Disk Controller The ProLiant DL760 G2 server provides an embedded dual-channel Smart Array 5i Controller. One channel is dedicated to

Strany 225 - WESTERN REGION

Server Features Video The HP Integrated PCI Video Controller with 8 MB of video RAM can obtain a maximum resolution of 1280 x 1024 in 32-bit true colo

Strany 226

Server Features Redundant Hot-Plug Fans ProLiant DL760 G2 servers include 1 + 1 redundant hot-plug fans. If a fan fails, the server generates a system

Strany 227 - SERVICE CONTRACT

Server Features Optional Features The ProLiant DL760 G2 server supports a wide range of server hardware options. HP server options are available from

Strany 228

Server Features Server Configuration and Management Features HP offers an extensive set of features and tools to support effective server configuratio

Strany 229 - Navigating the Menus

Server Features ROM-Based Setup Utility The ROM-Based Setup Utility (RBSU) automatically configures the system based on the selected operating system.

Strany 230 - Display Symbols

Server Features Smart Components for Online ROM Flash Online ROM flash technology consists of a combination of components that allow system administra

Strany 231

Server Features Smart Array 5302/32 and 5302/64. This new Advanced RAID level offers dramatically higher fault tolerance than RAID 5 with lower implem

Strany 232

Server Features HP Utilities for Linux HP servers running Linux can take advantage of several utilities that provide detailed system information, incl

Strany 233

Server Features Insight Manager 7 features an easy-to-use graphical interface and includes online documentation and context-sensitive help. Key featur

Strany 234 - Integrated Management Log

Contents Fixed Internal Media Drive Bays ...1-13 iv HP ProLiant DL760 Genera

Strany 235

Server Features Integrated Management Log The IML records all system events and stores them in an easily viewable form. These events are recorded and

Strany 236

Server Features Diagnostic Tools Software, firmware, and hardware diagnostic features of the ProLiant DL760 G2 server include: • Diagnostic LED indic

Strany 237

Server Features Security Features The following sections outline the security features available for the ProLiant DL760 G2 server. Software Security T

Strany 238

Server Features Hardware Security The following hardware security features are available in the ProLiant DL760 G2 server: • A switch on the I/O board

Strany 239 - Insight Manager 7

Server Features HP ProLiant DL760 Generation 2 Server User Guide 1-27 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: b-ch1 Server Features.doc

Strany 240 - Survey Utility

2 Installing the Server in a Rack This chapter specifies the procedures required to install a ProLiant DL760 G2 server into an HP or industry-standar

Strany 241

Installing the Server in a Rack Rack Installation Overview Installing the ProLiant DL760 G2 server in a rack requires the following steps (detailed la

Strany 242

Installing the Server in a Rack Selecting a Site When installing the ProLiant DL760 G2 server in a rack, the following standards must be met: • Space

Strany 243

Installing the Server in a Rack CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airf

Strany 244

Installing the Server in a Rack • If a power strip is used, the load should not exceed 80 percent of the marked electrical current rating of the powe

Strany 245 - Mouse Compliance Statement

Contents Shipping Screws ... 2-12 Security Screw...

Strany 246 - European Union Notice

Installing the Server in a Rack Power Supplies • The ProLiant DL760 G2 server has two hot-plug, redundant power supplies. Depending on the system loa

Strany 247 - BSMI Notice

Installing the Server in a Rack Grounding Requirements WARNING: To reduce the risk of electrical shock due to high leakage currents, a reliable, gr

Strany 248 - Laser Safety Warnings

Installing the Server in a Rack Temperature Requirements To be sure of continued safe and reliable operation of the equipment, install the system in a

Strany 249 - Power Cords

Installing the Server in a Rack Shipping Box Contents Unpack the shipping boxes by following the instructions and illustrations printed on the outsid

Strany 250 - Battery Replacement Notice

Installing the Server in a Rack Shipping Brackets To protect the power supply and I/O module from any damage during shipment, each component is instal

Strany 251 - Electrostatic Discharge

Installing the Server in a Rack 2. Remove the I/O shipping bracket by loosening the retaining screws (1) and lifting the bracket up and out (2). Fig

Strany 252 - Grounding Methods

Installing the Server in a Rack Shipping Screws To prevent damage to the processor and memory module during shipping, the server ships with a shipping

Strany 253 - Server Error Messages

Installing the Server in a Rack Security Screw The ProLiant DL760 G2 server has a top latch security screw as shown in Figure 2-5. The screw prevents

Strany 254 - LED Indicators and Switches

Installing the Server in a Rack 2. Tighten the internal security screw between the processor and memory module and the I/O module as shown in Figure

Strany 255 - System Power LED Indicator

Installing the Server in a Rack Stabilizers The anti-tip stabilizer provides stability and support when equipment is installed, removed, or accessed w

Strany 256

Contents Chapter 5 Installing Hardware Options, Hot-Pluggable Hot Plug RAID Memory...

Strany 257

Installing the Server in a Rack Warnings and Precautions Before beginning the following procedures, be sure you understand the following warnings: 6

Strany 258

Installing the Server in a Rack IMPORTANT: Refer to the following rack documentation for further cautions: • 9000 Rack Series Products Audio-Visual

Strany 259

Installing the Server in a Rack WARNING: Reduce the risk of personal injury or damage to the equipment by ensuring that the rack leveling feet exte

Strany 260

Installing the Server in a Rack To identify the required space and location for the server with the template: 1. Attach the rack template to the fron

Strany 261

Installing the Server in a Rack 3. Remove the template from the rack, leaving the gray plastic covers in place. Figure 2-8: Removing the template 4

Strany 262

Installing the Server in a Rack 5. Reverse and secure the back of the template to the vertical rack columns at the rear of the rack by pressing the t

Strany 263 - Hot-Plug Fan LED Indicators

Installing the Server in a Rack Installing the Slide Bracket Assemblies To install the slide bracket assemblies in the rack: 1. Install the slide bra

Strany 264

Installing the Server in a Rack 3. Lock the slide bracket assembly by letting the lock lever spring back to the original position (1) and making sure

Strany 265

Installing the Server in a Rack Lightening the Chassis WARNING: The processor and memory module weighs more than 16 kg (35 lb). HP recommends eithe

Strany 266

Installing the Server in a Rack Attaching the Inner Slide Members To attach the inner slide members to the server chassis: 1. Align the slots on the

Strany 267

Contents Chapter 7 HP ProLiant DL760 Generation 2 Server User Guide vii HP CONFIDENTIAL Writer: Jennifer Hayward File Name: a-frnt.doc Codename: Pi

Strany 268 - Switches

Installing the Server in a Rack Installing the Server in the Rack To install the server in the rack: 1. Fully extend both intermediate slide members

Strany 269 - Troubleshooting Information

Installing the Server in a Rack 2. Lift the server using the handles on both sides (1) and carefully connect both server inner slide members into the

Strany 270 - Server Startup Problems

Installing the Server in a Rack 3. Push the server slide locks back (1) and slide the server into the rack (2). Figure 2-16: Sliding the server int

Strany 271

Installing the Server in a Rack 6. Attach the cable management arm bracket to the back of the server (1) and tighten the thumbscrew (2). Figure 2-17

Strany 272 - Table E-1: Diagnosis Steps

Installing the Server in a Rack 7. Attach the cable management arm to the cable management arm bracket and tighten the two thumbscrews. Figure 2-18:

Strany 273 - LED location

Installing the Server in a Rack 10. Cable the server. CAUTION: To prevent data corruption, do not connect the server to a low line power source (1

Strany 274

Installing the Server in a Rack 2-32 HP ProLiant DL760 Generation 2 Server User Guide HP CONFIDENTIAL Writer: Jennifer Hayward File Name: c-ch2 Ins

Strany 275

3 Server Access The ProLiant DL760 G2 server provides easy access to all internal components for installation and maintenance. This chapter provides

Strany 276

Server Access Server I/O Lid and Modules The ProLiant DL760 G2 server chassis facilitates the installation of hardware upgrades through the use of thr

Strany 277

Server Access Accessing the I/O Module To access the I/O module in order to install or replace hot-plug fans or hot-plug PCI boards: 1. Slide the ch

Strany 278

Contents Insight Manager 7 ...9-20 viii HP Pro

Strany 279

Server Access Removing the I/O Module Use the procedure in the preceding section, “Accessing the I/O Module,” to install or replace hot-plug fans or h

Strany 280

Server Access 5. Press in the sides of the cam levers on the I/O module (1) and rotate the top of the levers downward (2), as shown in Figure 3-3. 6.

Strany 281

Server Access 8. Set the I/O module aside for servicing non-hot-plug components. WARNING: To reduce the risk of personal injury from hot surfaces,

Strany 282

Server Access 3. Press in the sides of the cam levers on the processor and memory module (1), and rotate the top of the levers downward (2) as shown

Strany 283

Server Access 5. Press in the module stop latches (1) and pull the module out of the chassis (2), as shown in Figure 3-6. Figure 3-6: Removing the

Strany 284

Server Access Processor and Memory Module Components Refer to Figure 3-7 to identify components in the processor and memory module. Figure 3-7: Proc

Strany 285 - Problems After Initial Boot

Server Access Removing the Media Module CAUTION: Do not attempt to remove the media module while power is applied to the system. The module is not

Strany 286

Server Access 5. Press in the module stop latches (1) and pull the module out of the chassis (2). Figure 3-9: Removing the media module WARNING:

Strany 287

Server Access 6. To reassemble the server, slide the module into the chassis until the cam levers begin to rotate (1). Then push the cam levers upwar

Strany 288 - Remote-Flash Redundant ROM

Server Access HP ProLiant DL760 Generation 2 Server User Guide 3-13 HP CONFIDENTIAL Writer: Jennifer Hayward File Name: d-ch3 Server Access.doc Cod

Strany 289 - °F 38.7°C

Contents System Interconnect LED Indicators ... D-4 System Attention LED Indicator

Strany 290 - System Battery

4 Installing Hardware Options, Server Power Off The following instructions are provided as an overview for installing hardware option upgrades that r

Strany 291

Installing Hardware Options, Server Power Off Intel Xeon Processor MP The ProLiant DL760 G2 server supports either four or eight processors. • All p

Strany 292 - COMPAQ CONFIDENTIAL

Installing Hardware Options, Server Power Off Installing a Processor Board The ProLiant DL760 G2 server is capable of supporting up to eight Intel Xeo

Strany 293

Installing Hardware Options, Server Power Off To install a processor board option kit (with four processors) into the processor and memory module: W

Strany 294

Installing Hardware Options, Server Power Off 7. Insert the processor board into processor board slot 2 of the module (1). 8. Push down the processo

Strany 295

Installing Hardware Options, Server Power Off External Tape Drive Storage Devices Optional external tape drive mass storage devices can be connected t

Strany 296

Installing Hardware Options, Server Power Off 8. Install the SCSI terminator supplied on the other external SCSI connector on the rear panel of the e

Strany 297

Installing Hardware Options, Server Power Off Locating the I/O Expansion Slots The I/O expansion slots are located in the I/O module. Figure 4-6: Lo

Strany 298

Installing Hardware Options, Server Power Off The I/O expansion slots are distributed among one PCI bus and five separate PCI-X buses. NOTE: It is r

Strany 299

Installing Hardware Options, Server Power Off To add an expansion board: 1. Press the top of the appropriate expansion slot release lever (1) and ope

Komentáře k této Příručce