HP NetRAID-4M Cluster Services Installation Guide Hardware, Drivers and Utilities
6
2.2 Install the NetRAID-4M and Heartbeat NIC
1. Power off both Server A and Server B.
2. Disconnect all cables from the back of Server A.
3. If working on a racked server, extend the rack enclosure foot.
4. Extend Server A and open the cover to gain access to the PCI slots.
5. Insert an HP D5013B NIC into any 32-bit slot available in the server:
6. Verify that the HP NetRAID-4M termination jumpers are installed as shown in the
following graphic.
7. Verify the Battery Enable Jumper is properly installed on both pins as shown below.
NOTE Note: The card ships from HP with this jumper installed on only one of the two
pins.
8. Insert the HP NetRAID-4M into any 64-bit PCI slot available in the server.
9. Close Server A and if working on a racked server, slide the server back into the rack
enclosure.
10. Reconnect the video, keyboard, mouse, power, and network cables.
Jumpers