Description
Verifies whether vdisk redundancy data is consistent with its user data. For RAID 3, 5, 6, and 50,
verify checks all parity blocks to find data-parity mismatches. For RAID 1 and 10, verify compares
the primary and secondary disks to find data inconsistencies.
Verification can last over an hour, depending on vdisk size, utility priority, and amount of I/O
activity. When verification is complete, the number of inconsistencies found is reported with event
code 21 (
Vdisk verification complete
) in the event log. Such inconsistencies can indicate
that a disk in the vdisk is going bad. You can use a vdisk while it is being verified.
Syntax
verify vdisk
vdisks
Parameters
vdisks
Name or serial number of the vdisks to verify. For syntax, see
Command syntax
.
Example
Verify vdisk
VD1
:
# verify vdisk VD1
Info: Verify started on vdisk VD1
Success: Command completed successfully