HP V8.5 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Multifunkční zařízení HP V8.5. HP V8.5 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - V8.5 Thermal Plotter

V8.5 Thermal PlotterUser GuideV8.5 Thermal Plotter is a product of iSys - The Imagaing Systems Group. © 2005

Strany 2

ixV8.5e Rev 2.2.2002B. INTERFACE CONNECTOR PIN ASSIGNMENT ... B-1C. CENTRONICS INTERFACE BOARD ... C-1

Strany 3

11-1V8.5e Rev 2.2.2002INTRODUCTION1.1 GENERAL DESCRIPTIONThe Imaging Systems Group’s V8.5e Thermal Plotter is a high-speedplotter suitable for offi

Strany 4

INTRODUCTION11-2 V8.5e Rev 2.2.2002An optional fan-fold paper guide and feeder trays (which attach tothe back of the plotter, and below the rackmount

Strany 5

22-1V8.5e Rev 2.2.2002SPECIFICATIONS2.1 FUNCTIONALOperationCommand panel Front mounted.LED display.Three push buttons.Online/Offline, Data and erro

Strany 6

SPECIFICATIONS22- 2 V8.5e Rev 2.2.2002~ Form feed adjust F2, F4, F8, tF, PF - selectsformfeed of 2, 4, 8 inches, Top of Formsensing, and programable p

Strany 7 - Contents

2SPECIFICATIONS2-3V8.5e Rev 2.2.2002MediaTypes Thermal sensitive paper or film.Rolled paper with 7/16 inch spool core.Rolled film.Fan-folded paper (op

Strany 8

SPECIFICATIONS22- 4 V8.5e Rev 2.2.2002TransportStepper motor Micro-step.Stepping resolution 0.004 millimeter.6400 micro-steps per inch of media.32 mic

Strany 9

2SPECIFICATIONS2-5V8.5e Rev 2.2.20022.3 PHYSICALDimensionsRackmount DesktopHeight 3.5 inches 3.5 inchesWidth 19 inches 15 inchesDepth 12.5 inches 1

Strany 10 - V8.5e Rev 2.2.2002

33-1V8.5e Rev 2.1.2001 INSTALLATION3.1 UNPACKINGAlthough shipments are thoroughly checked for completeness byThe Imaging Systems Group Inc., confir

Strany 11 - INTRODUCTION

INSTALLATION33-2 V8.5e Rev 2.2.2002Inspect the plotter and components for any damage that may haveoccurred during shipment. Report any damage to the c

Strany 12

iV8.5e Rev 2.2.2002COPYRIGHT NOTICEThis document is copyrighted by The Imaging Systems Group Inc.,2000. No part of this publication may be reproduced,

Strany 13 - SPECIFICATIONS

3INSTALLATION3-3V8.5e Rev 2.2.20023.3 INTERFACE SETUPPlug the power cord into a grounded AC outlet only. Avoid sharingan outlet that is also poweri

Strany 14

INSTALLATION33-4 V8.5e Rev 2.2.2002Installing rolled paperThe V8.5e plotter comes with a sample roll of thermal sensitive paper.To install rolled pape

Strany 15

3INSTALLATION3-5V8.5e Rev 2.2.2002Figure 3-1Control PanelPowerLatchFigure 3-2 Back PanelAC receptacle ScrewsAC Power & Fuse Back Panel Screws Data

Strany 16

INSTALLATION33-6 V8.5e Rev 2.2.2002Figure 3-3. Roll paper and film pathRollFigure 3-4 Roll paper installed

Strany 17

3INSTALLATION3-7V8.5e Rev 2.2.2002Latch BarFigure 3-5 Opening the plotter Lid

Strany 18 - INSTALLATION

INSTALLATION33-8 V8.5e Rev 2.2.2002Installing fan-fold paper1. Loosen the rackmount thumbscrews and pull the plotter forwardon the rails.2. Release th

Strany 19

3INSTALLATION3-9V8.5e Rev 2.2.2002CAUTION: Before plotting or testing on any print media, make surethat the media setting is correct. Incorrect sett

Strany 20

INSTALLATION33-10 V8.5e Rev 2.2.2002Figure 3-6 Spindle blocksSpindle blocks (1 per side)Figure 3- 7. Fanfold guide path

Strany 21

44-1V8.5e Rev 2.2.2002OPERATION4.1 POWER SUPPLY PRECAUTIONSTurn off the power switch on the plotter before doing any of thefollowing:1. Unplugging

Strany 22

OPERATION44-2 V8.5e Rev 2.2.2002Figure 4-1. Control panelThe control panel is shown in Figure 4-1. It consists of an LEDdisplay, two condition lights,

Strany 23 - 3-6 V8.5e Rev 2.2.2002

iiV8.5e Rev 2.2.2002ATTENTION: The V8.5e plotter generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance wi

Strany 24 - Latch Bar

4OPERATION4-3V8.5e Rev 2.2.2002nottuB noitcnuF.WORRAPU.1enilffO/enilnO.sedomENILFFOdnaENILNOneewtebselggoTebylnonacsgnitteslenaplortnocotsegnahCbusnoi

Strany 25

OPERATION44-4 V8.5e Rev 2.2.2002tseTPttolPtsartnoC deepS aideM gnilacSlacitreVnoitalumEhtgneLFFrepsetyBnacselacsyerGaidemelbatsserPPU/WORRAMROFDEEFsse

Strany 26

4OPERATION4-5V8.5e Rev 2.2.2002Changing function settingsFor easy reference in this section, the buttons are referred to asnumbers 1, 2, and 3, from t

Strany 27 - Spindle blocks (1 per side)

OPERATION44-6 V8.5e Rev 2.2.2002Default SettingsTo restore the default settings of the plotter, press and hold themenu button (button 3) while powerin

Strany 28 - OPERATION

4OPERATION4-7V8.5e Rev 2.2.2002If the contrast needs further adjusting, change the contrast settingby starting at the lowest value, adjust the contra

Strany 29

OPERATION44-8 V8.5e Rev 2.2.2002is set to film or grayscale mode the printhead’s requirement forstrobe times is raised. This requires a slower plot sp

Strany 30 - 4-3V8.5e Rev 2.2.2002

4OPERATION4-9V8.5e Rev 2.2.2002ScalingThe scaling function stretches or shrinks the plot over a 36-inchlength of plot with settings being S0 through S

Strany 31 - 4-4 V8.5e Rev 2.2.2002

OPERATION44-10 V8.5e Rev 2.2.2002Emulation (vertical resolution)The emulation function adjusts the vertical resolution of the plot(along the media len

Strany 32

4OPERATION4-11V8.5e Rev 2.2.2002PF - Programmable advance past Top of Form- This feature allowsthe V8.5e to line up with the beginning of pages when a

Strany 33

OPERATION44-12 V8.5e Rev 2.2.2002Bytes per scanThe SCANWDTH function adjusts the scan width of the plot, definedin bytes per line. The default scan w

Strany 34

iiiV8.5e Rev 2.2.2002Caution! – must be observed to avoid loss or damage to yourequipment.Important: - must be observed to avoid operational impairmen

Strany 35

4OPERATION4-13V8.5e Rev 2.2.2002Grayscale media table numbert1 - media calibration table for media 1.t2 - media calibration table for media 2.These ta

Strany 36

OPERATION44-14 V8.5e Rev 2.2.2002Byte 3: speed 1”=21 1.0 inches/sec2”=22 2.0 inches/sec3”=23 3.0 inches/sec4”=24 4.0 inches/secNo Change=00Byte 4: med

Strany 37

4OPERATION4-15V8.5e Rev 2.2.2002Byte 6: emulation P0=51 200 scans/inch verticalwith positivescalingn0=52 200 scans/inch verticalwith negativescalingP3

Strany 38

OPERATION44-16 V8.5e Rev 2.2.2002Byte 10: line feed 0AExample: To set the plotter to: contrast=C3speed=1.0 ipsmedia=LPscaling=S2emulation=P3formfeed=F

Strany 39

4OPERATION4-17V8.5e Rev 2.2.20024.4 FEHLERMELDUNGEN1. Medien leer: Am Plotter erscheint eine kleine quadratischeblinkende Anzeige und die Fehleranzei

Strany 40

55 - 1V8.5e Rev 2.2.2002THEORY OF OPERATION5.1 INTRODUCTIONThe V8.5e plotter uses thermal technology to convert data from thehost computer into plo

Strany 41

THEORY OF OPERATION55 - 2 V8.5e Rev 2.2.20028-bit Parallel DataData InputInterfaceData BufferNon-volitileRAM24 V CPowerSupplyMotor5 V DCPowerSupplyMic

Strany 42

5THEORY OF OPERATION5 -3V8.5e Rev 2.2.2002Stepper motorThe V8.5e uses a bipolar, two-phase stepper motor. The motor ismicro-step driven, requiring 200

Strany 43

THEORY OF OPERATION55 - 4 V8.5e Rev 2.2.2002langiS-nommehNcilangiSemaNevitcAleveLnoitarepO-1DNI8DNIatadtupnIhgiHlellarapetybrofseniltupnIdeinapmoccaeb

Strany 44

5THEORY OF OPERATION5 -5V8.5e Rev 2.2.2002Table 5-3. Remote function signalslangiScinomenMemaNlangiSlangiSleveLnoitarepORAELCraelcetomeRwoL.reffubtupn

Strany 45 - THEORY OF OPERATION

ivV8.5e Rev 2.2.2002Bitte verfahren Sie erst dann weiter, wenn Sie die Bedeutung dervorstehenden Hinweise vollständig verstanden haben.Elektromagnetis

Strany 46 - 5 - 2 V8.5e Rev 2.2.2002

THEORY OF OPERATION55 - 6 V8.5e Rev 2.2.2002Data ratesThe plotter accommodates a wide range of data rates. The speed ofthe plotter can be set to 1.0,

Strany 47 - Table 5-1 Status Signals

5THEORY OF OPERATION5 -7V8.5e Rev 2.2.2002Scan widthScan width settings sent from host software can specify the numberof bytes of data that will be pl

Strany 48 - Table 5-2 Data Transfer

THEORY OF OPERATION55 - 8 V8.5e Rev 2.2.2002Print modeWhen the host asserts the PRINT mode signal, the plotter cangenerate ASCII characters. Table 5-5

Strany 49 - 5 -5V8.5e Rev 2.2.2002

5THEORY OF OPERATION5 -9V8.5e Rev 2.2.20025.4 THERMAL PRINTHEADThe thermal printhead is comprised of a row of 1728 heater elements(nibs). Each bit

Strany 50 - Table 5-4. Minimum data rates

THEORY OF OPERATION55 - 10 V8.5e Rev 2.2.2002Film mediaWhen the plotter is set to film mode, the strobe length is increasedto accommodate the thicker

Strany 51

66-1V8.5e Rev 2.2.2002NOTE: Do not attempt to repair or modify any component of theV8.5e. If a component fails, it may be replaced free of charge in

Strany 52 - Table 5-5. Mode signals

MAINTENANCE66 -2 V8.5e Rev 2.2.2002This symbol indicates an area of possible concern dueto static discharge into the circuitry. When you see thissymb

Strany 53

6MAINTENANCE6 - 3V8.5e Rev 2.2.20026.2 REGULAR MAINTENANCEThe V8.5e thermal plotter is engineered to require minimalpreventative maintenance. If th

Strany 54

MAINTENANCE66 -4 V8.5e Rev 2.2.2002Cleaning the thermal printheadAfter prolonged use, the thermal printhead picks up fibres from themedia passing unde

Strany 55 - MAINTENANCE

6MAINTENANCE6 - 5V8.5e Rev 2.2.20022. Moisten (do not soak) a soft, lint-free cloth or cotton swab with99% pure isopropyl alcohol. Rub gently along th

Strany 56

vV8.5e Rev 2.2.2002LIMITATION OF LIABILITYThe Imaging Systems Group’s total liability to the purchaser, or toany third party, for damages from any and

Strany 57

MAINTENANCE66 -6 V8.5e Rev 2.2.2002Replacing the fuseThe fuse is located in a clip next to the AC receptacle. Figure 3-2.1. Unplug the power cable fro

Strany 58 - Figure 6-1

77-1V8.5e Rev 2.2.2002TROUBLESHOOTING7.1 INTRODUCTIONThis chapter provides a list of problems that may be encounteredwith the V8.5e, and gives poss

Strany 59

TROUBLESHOOTING77-2 V8.5e Rev 2.2.20027.2 PROBLEMSPlotter does not plotPossible causes: Plotter has no paper or filmLid is not securely closedTherm

Strany 60

7TROUBLESHOOTING7-3V8.5e Rev 2.2.2002Plot has vertical white stripesFigure 7-3 . Plot with vertical white stripesPossible causes: Lid is not securely

Strany 61 - TROUBLESHOOTING

TROUBLESHOOTING77-4 V8.5e Rev 2.2.2002Plot is blotchy or fadedFigure 7-4 . Blotchy or faded plotThis problem originates from inconsistent printhead pr

Strany 62

7TROUBLESHOOTING7-5V8.5e Rev 2.2.2002Plot contrast is weakPossible causes: Lid is not securely closedLatch pins need adjustmentMedia setting is incorr

Strany 63

TROUBLESHOOTING77-6 V8.5e Rev 2.2.2002Plot has black vertical linesFigure 7-6 . Plot with black vertical linesPossible Cause: One or more bits in each

Strany 64

7TROUBLESHOOTING7-7V8.5e Rev 2.2.2002Plot is wrong lengthIf you suspect that a plot is the wrong length, plot a job of a knownlength and measure it.Po

Strany 65

TROUBLESHOOTING77-8 V8.5e Rev 2.2.20023. If the lid does not close securely, or if the head pressure is toolow, contact your authorized service center

Strany 66

7TROUBLESHOOTING7-9V8.5e Rev 2.2.2002Plot output speed is erraticPossible Cause: Plotter speed is set too high. This is most likelyto occur on the HIG

Strany 67

viV8.5e Rev 2.2.2002Contents1. INTRODUCTION ... 1-11.1 GENERAL DESCRIPTION ... 1-11.2 MEDIA DESCRIPT

Strany 68

TROUBLESHOOTING77-10 V8.5e Rev 2.2.2002Figure 7-7 . “Blooming” plotPossible Cause:Media setting is incorrect. The thermalprinthead operating temperatu

Strany 69

7TROUBLESHOOTING7-11V8.5e Rev 2.2.2002Form feed stops before desired lengthPossible Cause: The form feed length is too short. The formfeed stops befor

Strany 70 - Figure 7-7 . “Blooming” plot

TROUBLESHOOTING77-12 V8.5e Rev 2.2.2002Plot is skewed or unreadableFigure 7-8 . Skewed plotPossible Cause: The scan width is incorrect.Solution:1. Ad

Strany 71

88-1V8.5e Rev 2.2.2002The Imaging Systems Group Inc. (iSys) warrants our V8.5e plottersto be free from defects in materials and workmanship as follow

Strany 72 - Figure 7-8 . Skewed plot

WARRANTY88-2 V8.5e Rev 2.2.2002TERMS and CONDITIONS of Hot Swap and Post Hot Swapa) The product MUST be returned in the original or properpacking mate

Strany 73 - WARRANTY

AA-1V8.5e Rev 2.2.2002APPENDIXASCII TABLESMSN: Most significant nibbleLSN: Least significant nibbleTable A-1. Normal ASCII character setTable A-2. ASC

Strany 74

BB-1V8.5e Rev 2.2.2002APPENDIXINTERFACE CONNECTOR PIN ASSIGNMENTTable B-1. Versatec cable pin outs (straight through)niPlangiS niPnruteR emaNlangiS c

Strany 75 - ASCII TABLES

BB-2V8.5e Rev 2.2.2002INTERFACE CONNECTOR PIN ASSIGNMENTniP langiS niP langiS1EBORTS41TXFA20ATAD51RORRE31ATAD61TESER42ATAD71NITCLS53ATAD81DNG64ATAD91

Strany 76 - APPENDIX

CC - 1V8.5e Rev 2.2.2002APPENDIXCENTRONICS INTERFACE BOARDThe new Centronics adapter (rev1-2) implements some improve-ments over the previous (rev1-1)

Strany 77 - V8.5e Rev 2.2.2002

CC - 2V8.5e Rev 2.2.2002C E N T R O N I C S I N T E R F A C E B O A R DOnce the V8.5E Centronics adapter is set to raster mode itwill remain in ra

Strany 78 - CENTRONICS INTERFACE BOARD

viiV8.5e Rev 2.2.20024. OPERATION ... 4-14.1 POWER SUPPLY PRECAUTIONS ... 4-14.2 USING THE CONTROL PAN

Strany 79

CC E N T R O N I C S I N T E R F A C E B O A R DC - 3V8.5e Rev 2.2.2002Specifying XX YY at values greater than those indicatedwill cause the V8.5

Strany 80

viiiV8.5e Rev 2.2.20025.5 MEDIA SENSORS ....... 5-106. MAINTENANCE ....... 6-16.1 MAINTENANCE GUIDELINES

Komentáře k této Příručce