HP B-series Embedded Switches Uživatelský manuál Strana 129

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 270
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 128
The SAN Management Application
129Fabric OS Procedures Version 3.1.x/4.1.x User Guide
2. At the command line enter the msconfigure command. The command
becomes interactive.
3. At the select prompt enter 2 to add a member based on its Port/Node WWN.
4. At the prompt enter the WWN of the member you would like to add to the
ACL. Press the Return key, and the main menu is displayed.
5. At the prompt enter 1 to verify the WWN you entered was added to the ACL.
6. Once you have verified that the WWN was added correctly, enter 0 at the
prompt to end the session.
7. At the “Update the FLASH?” prompt enter Y.
8. Press Enter to update the flash and end the session.
Example:
switch:admin> msconfigure
0 Done
1 Display the access list
2 Add member based on its Port/Node WWN
3 Delete member based on its Port/Node WWN
select : (0..3) [1] 2
Port/Node WWN (in hex): [00:00:00:00:00:00:00:00]
*WWN is successfully added to the MS ACL.
0 Done
1 Display the access list
2 Add member based on its Port/Node WWN
3 Delete member based on its Port/Node WWN
select : (0..3) [2] 1
<< Continued on next page.>>