HP Ethernet BL-c Switch Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Síťové přepínače HP Ethernet BL-c Switch. HP Ethernet BL-c Switch User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 66
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP 1:10Gb Ethernet BL-c Switch
User Guide
Part Number 445876-001
May 2007 (First Edition)
Zobrazit stránku 0
1 2 3 4 5 6 ... 65 66

Shrnutí obsahu

Strany 1 - User Guide

HP 1:10Gb Ethernet BL-c Switch User Guide Part Number 445876-001 May 2007 (First Edition)

Strany 2 - Audience assumptions

Introduction 10 ten Gigabit external Ethernet ports and sixteen internal Gigabit Ethernet ports providing connectivity to the blade servers within th

Strany 3 - Contents

Introduction 11 • High availability VRRP Layer 3 switching provides more power, flexibility, and security capabilities to network administrators. Ne

Strany 4 - Contents 4

Introduction 12 are members of a specific IP network. This is achieved by configuring the address/mask of that specific network as a restricted manag

Strany 5 - Contents 5

Introduction 13 RADIUS The switch supports the RADIUS method to authenticate and authorize remote administrators for managing the switch. This method

Strany 6 - Introduction

Introduction 14 • The accounting attributes of protocol, start_time, stop_time, and elapsed_time. For BBI users, accounting stop records are only se

Strany 7

Introduction 15 through a procedure called auto-negotiation. Auto-negotiation involves probing the capability of the network using low-level signalin

Strany 8 - Configuration and management

Component identification 16 Component identification In this section 1:10Gb Ethernet Blade Switch front panel ...

Strany 9 - Switch architecture

Component identification 17 Item Description 6 XFP transceiver cage port 21 • Green—Link LED (top) • Flashing green—Activity LED (bottom) 7 RJ-4

Strany 10 - Supported technologies

Installing the switch 18 Installing the switch In this section Preparing for installation ...

Strany 11 - Spanning Tree Protocol

Installing the switch 19 • Switch IP settings • VLAN settings • XFP settings • Port names and types • Port trunking settings • Interswitch X-C

Strany 12 - Introduction 12

© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Strany 13 - TACACS+

Installing the switch 20 NOTE: It is recommended to change the default switch passwords after initial configuration and as regularly as required

Strany 14 - Introduction 14

Installing the switch 21 Switch IP addresses are acquired by default using BOOTP, therefore, each switch has a unique IP address. Each switch is rem

Strany 15 - Redundant images in firmware

Installing the switch 22 A successful installation is indicated by a green Health LED. If the Health LED is amber or power is not applied to the

Strany 16 - Component identification

Installing the switch 23 NOTE: If the switch does not obtain the IP address by means of the BOOTP service, access the switch locally and config

Strany 17

Installing the switch 24 Installing XFP transceivers CAUTION: To prevent damage to the fiber optic cable or the XFP transceiver, do not install

Strany 18 - Installing the switch

Installing the switch 25 • Firmware Upgrade Smart Component (for Microsoft Windows only)—Provides quick and easy installation of the switch firmwar

Strany 19 - Switch security

Replacing a switch 26 Replacing a switch In this section Replacing an existing switch...

Strany 20 - Using a configuration file

Replacing a switch 27 5. Close the ejector lever and wait for the switch boot up completely. 6. If the configuration file was saved to a TFTP serve

Strany 21

Regulatory compliance notices 28 Regulatory compliance notices In this section Class A equipment ...

Strany 22 - Accessing the switch

Regulatory compliance notices 29 European Union regulatory notice This product complies with the following EU Directives: • Low Voltage Directive 2

Strany 23

Contents 3 Contents Introduction...

Strany 24 - Installing XFP transceivers

Regulatory compliance notices 30 Korean class A notice Laser compliance This product may be provided with an optical storage device (that is, CD o

Strany 25 - Installing the switch 25

Technical specifications 31 Technical specifications In this section General specifications ...

Strany 26 - Replacing a switch

Technical specifications 32 Category Specification 100Base-TX Two Pair or Four Pair UTP Category 5 (100 m) EIA/TIA-568 100-ohm STP (100 m) 1000Base

Strany 27 - Reference Guide

Technical specifications 33 Port type Port number Port name STP Server 4 Downlink4 Disabled Server 5 Downlink5 Disabled Server 6 Downlink6 Disabl

Strany 28 - Canadian notice

Technical specifications 34 Setting Value Primary default gateway 0.0.0.0 Secondary default gateway 0.0.0.0 Primary DNS server address 0.0.0.0 Seco

Strany 29 - Japanese class A notice

Technical specifications 35 Setting Value Port Trunking Load Sharing Algorithm The algorithm selects the following as forwarding ports for forwardin

Strany 30 - Laser compliance

Technical specifications 36 Setting Value Serial Port Parity Bit None Serial Port Stop Bit 1 Serial Port Flow Control None Default VLAN Default

Strany 31 - Technical specifications

Technical specifications 37 Setting Value RADIUS Server Port 1645 RADIUS Server Retries 3 RADIUS Server Timeout 3 RADIUS Backdoor for Telnet Acce

Strany 32 - • VLAN Name—Default VLAN

Technical specifications 38 Setting Value Aggregate IGMP Report Disabled IGMP Fastleave Disabled IGMP Fastleave VLANs None IGMP Filtering Disabl

Strany 33 - General default settings

Technical specifications 39 Setting Value RMON Alarm Falling Event Index 0 RMON Alarm Owner Null IP Forwarding Disabled Configurable User Name - a

Strany 34 - Setting Value

Contents 4 Installing XFP transceivers...

Strany 35

Technical specifications 40 Setting Value SNMPv3 - v1v2only subtree=1, included subtree=1.3.6.1.6.3.15, excluded subtree=1.3.6.1.6.3.16, excluded s

Strany 36

Technical specifications 41 Category Specification Best downlink external port packet forwarding rate ratio 16 : 5 Interswitch x-connects across enc

Strany 37

Performing a serial download 42 Performing a serial download In this section Introduction ...

Strany 38

Performing a serial download 43 4. Hold down the Shift key and press the D key repeatedly during the Memory Test, until this message appears: N

Strany 39

Performing a serial download 44 8. Select <Transfer-Send File> from the menu and choose these options in the Send File window: The Send File

Strany 40 - Performance specifications

Performing a serial download 45 Serial upgrade of operating system firmware procedure To perform a serial upgrade of the switch operating system fir

Strany 41 - Category Specification

Performing a serial download 46 NOTE: To perform serial downloads at 57600 baud rate, press the Shift-F keys. To perform serial downloads at 1152

Strany 42 - Performing a serial download

Performing a serial download 47 Depending on the selection, 1 or 2, the system updates image1 or image2 on the flash and a message with a progress i

Strany 43

SNMP MIBs support 48 SNMP MIBs support In this section MIB overview...

Strany 44

SNMP MIBs support 49 Supported MIBs The SNMP agent for the switch supports these MIBs: • dot1x.mib • GbE2c-1-10G-L2L3.mib • GbE2c-1-10G-L2L3_cpqh

Strany 45

Contents 5 Cannot connect to the switch console interface remotely using SSH... 57 Canno

Strany 46

SNMP MIBs support 50 o risingAlarm o fallingAlarm • GbE2c-1-10G-L2L3.mib traps o bntSwDefGwUp o bntSwDefGwDown o bntSwDefGwInService o bntSwDe

Strany 47

Electrostatic discharge 51 Electrostatic discharge In this section Preventing electrostatic discharge...

Strany 48 - SNMP MIBs support

RJ-45 pin specification 52 RJ-45 pin specification In this section Standard RJ-45 receptacle/connector...

Strany 49 - Supported traps

RJ-45 pin specification 53 RJ-45 to DB-9 serial adapter with flow control pin assignment RJ-45 signals RJ-45 pins DB-9 pins DB-9 signals Re

Strany 50

Troubleshooting 54 Troubleshooting In this section Forgotten administrator user name and password that was configured on the switch...

Strany 51 - Electrostatic discharge

Troubleshooting 55 • The server blade enclosure is not powered up. Be sure that the server blade enclosure is powered up and all the power connectio

Strany 52 - RJ-45 pin specification

Troubleshooting 56 Error message that the switch failed to complete the system self-testing appears on the serial console screen Action: The system d

Strany 53

Troubleshooting 57 • The setting allowing access to the switch using the Telnet interface is disabled. From the serial console interface, be sure th

Strany 54 - Troubleshooting

Troubleshooting 58 The port activity LEDs continuously indicate activity after connecting more than one port to another switch or destination device

Strany 55 - Troubleshooting 55

Troubleshooting 59 The switch does not let the user enable two adjacent ports into two different VLANs while assigning the ports to VLANs Action: The

Strany 56 - Troubleshooting 56

Introduction 6 Introduction In this section Additional references...

Strany 57

Troubleshooting 60 o Be sure that a valid configuration file exists on the TFTP server to download to the switch. o On the switch, check the file n

Strany 58 - Troubleshooting 58

Acronyms and abbreviations 61 Acronyms and abbreviations AAA authentication, authorization, and accounting BBI browser-based interface BOOTP Boots

Strany 59

Acronyms and abbreviations 62 IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Management Protocol IP Internet Protocol

Strany 60 - Troubleshooting 60

Acronyms and abbreviations 63 NTP network time protocol NVRAM non-volatile memory OID object identifier OS operating system OSI Open Systems Int

Strany 61 - Acronyms and abbreviations

Acronyms and abbreviations 64 SCP Secure Copy SFP small form-factor pluggable SNMP Simple Network Management Protocol SSH Secure Shell STP Spann

Strany 62

Index 65 A accessing the switch serial console interface, troubleshooting 55 additional references 6 architecture 9 Auto-MDI/MDIX 14 auto-neg

Strany 63

Index 66 planning switch configuration 18 port mapping 9 port mirroring 12 port trunking 12 R redundancy 8, 10, 15 redundant crosslinks 1

Strany 64

Introduction 7 • 9K jumbo frames that improve performance by increasing application throughput and decreasing server processor utilization • Robust

Strany 65 - Index 65

Introduction 8 Switch redundancy In a dual switch configuration, the switches offer several redundancy and failover features. With these features, th

Strany 66 - Index 66

Introduction 9 • A text-based, human read/write configuration file provides viewing, printing, and editing capabilities. • A DNS client supports pr

Komentáře k této Příručce

Žádné komentáře