Diagnostic Tests
Testing the Hub Only
Choose one of the following procedures to test the hub’s internal circuitry. The first is the
most complete internal test. (The hub’s ports are not tested with the following procedures;
see the next page to test the ports.)
Cycle power on the hub by unplugging the power cord and then plugging it in.
This causes the hub to test itself. All LEDs should go ON momentarily before
returning to their operational states. If all do not go ON, an LED may be burned
out, or the hub is faulty. If the Fault LED on the front or back of the hub stays
ON, the hub is faulty and must be replaced.
Connect a console to the hub. Use the console’s Reset command, which causes the
hub to test itself. All LEDs should go ON momentarily before returning to their
operational states. If all do not go ON, an LED may be burned out, or the hub is
faulty. If the Fault LED on the front or back of the hub stays ON, the hub is
faulty and must be replaced. See chapter 3, “Operation”, for console command
details.
For the HP 28688B and HP 28699A only, use an HP network management
product to run a self-test. For instructions, see the network management
documentation.
4-4 Troubleshooting