The HP BladeSystem p-Class 1U power enclosure: hot-plug,
redundant power for a server blade enclosure
technology brief
Abstract.............................................................................................................................................. 3
Introduction......................................................................................................................................... 3
Components of the enclosure ................................................................................................................ 3
Hot-plug, redundant power supplies ................................................................................................... 3
Redundant AC power ....................................................................................................................... 4
Hot-plug power management module ................................................................................................. 5
Features of the enclosure ...................................................................................................................... 5
Bi-directional electronic e-fuse............................................................................................................ 5
Power zones.................................................................................................................................... 5
Firmware in mixed environments .................................................................................................... 6
Dynamic power saver....................................................................................................................... 7
Redundancy with dynamic power saver .......................................................................................... 7
Enabling dynamic power saver ...................................................................................................... 8
Serial port....................................................................................................................................... 8
Remote access to the serial port ................................................................................................... 10
Efficient cabling ............................................................................................................................. 10
Management link cable............................................................................................................... 11
Power distribution unit cables....................................................................................................... 11
Infrastructure configurations ................................................................................................................ 12
Using PDUs with the 1U power enclosure.......................................................................................... 13
Redundancy............................................................................................................................... 13
Maximum rated VA capacity ....................................................................................................... 13
Number of PDU outlets................................................................................................................ 13
Three-phase input ....................................................................................................................... 13
Dynamic power saver and three-phase input PDUs ......................................................................... 13
Standard configurations.................................................................................................................. 15
Using ProLiant BL35p server blades .............................................................................................. 15
Using ProLiant BL30p server blades .............................................................................................. 16
Using ProLiant BL20p server blades .............................................................................................. 17
Risks associated with extreme density ............................................................................................... 18
Supported configurations for the S348 Monitored PDU and S332 Monitored PDU................................. 18
North America/Japan................................................................................................................. 18
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1

The HP BladeSystem p-Class 1U power enclosure: hot-plug, redundant power for a server blade enclosure technology brief Abstract...

Strany 2

10 Remote access to the serial port IT administrators can enable remote access to the serial port in two different ways: 1. Through the HP Serial C

Strany 3 - Components of the enclosure

11 Management link cable To provide two-way communication, connect a management link cable from the power management module of the 1U power enclosure

Strany 4 - Redundant AC power

12 Infrastructure configurations When using the HP BladeSystem p-Class 1U power enclosure, follow the general guidelines in Table 4 to install the p

Strany 5 - Features of the enclosure

13 Using PDUs with the 1U power enclosure When using PDUs within an HP BladeSystem environment, key considerations include redundancy, volt-ampere (V

Strany 6 - 001_rev1_us.pdf

14 Power supplies installed in bay 2 in each of the 1U power enclosures should also be connected to a different phase on the PDU. Figure 8 illustrate

Strany 7 - Dynamic power saver

15 Standard configurations The following configurations review some common usage scenarios for the HP BladeSystem p-Class 1U power enclosure, includi

Strany 8 - Serial port

16 Using ProLiant BL30p server blades In this configuration the rack contains four enhanced server blade enclosures, four 1U power enclosures and six

Strany 9

17 Using ProLiant BL20p server blades In this configuration, the rack contains six enhanced server blade enclosures, six 1U power enclosures, and six

Strany 10 - Efficient cabling

18 Risks associated with extreme density While it is possible to build a fully populated a rack with server blades and retain power supply and line c

Strany 11

19 47U rack Mounting the PDUs in the 1U configuration requires an additional 3U of vertical space in the rack. Three PDUs must be mounted facing the

Strany 12

International ... 18 Suppo

Strany 13

20 Standard 42U rack This configuration, while possible, may cause issues because of the limited access to the PDUs in the 0U space after all the ser

Strany 14

21 Figure 13. AC feed redundancy using the HP R5500XR UPS Conclusion The HP BladeSystem p-Class 1U power enclosure is a vital component of the HP

Strany 15 - Standard configurations

For more information For additional information, refer to the resources listed below. Resource description Web address HP BladeSystem website www.h

Strany 16

3 Abstract The HP BladeSystem p-Class1U power enclosure provides hot-plug, redundant power for a single enclosure of HP ProLiant BL p-Class server bl

Strany 17

4 Figure 1. HP BladeSystem p-Class 1U power enclosure bays Table 1. HP BladeSystem p-Class 1U power enclosure bay descriptions Item Description C

Strany 18 - Monitored PDU

5 Hot-plug power management module The hot-plug power management module monitors the power subsystem components and regulates the power-up sequence o

Strany 19

6 down to the next enclosure and continues until the bottom right blade in the bottom server blade enclosure is powered. In a rack that contains man

Strany 20

7 Dynamic power saver The dynamic power saver feature in the HP BladeSystem p-Class 1U power enclosure provides for efficient use of power in the ser

Strany 21 - Conclusion

8 Enabling dynamic power saver To configure the dynamic power saver, the power management module must be removed from the 1U power enclosure and the

Strany 22 - For more information

9 Status information Description Power supply redundancy (enclosure N+1 redundancy) Indicates whether there are sufficient power supplies to take ov