HP Integrity rx7640 and HP 9000 rp7440 Servers
Third Edition
Manufacturing Part Number : AB312-9001C
January 2007
Printed in the U.S.A.
© Copyright 2007
Zobrazit stránku 0
1 2 3 4 5 6 ... 100 101

Shrnutí obsahu

Strany 1 - Installation Guide

Installation Guide HP Integrity rx7640 and HP 9000 rp7440 ServersThird EditionManufacturing Part Number : AB312-9001CJanuary 2007Printed in the U.S.A.

Strany 3 - Contents

Index100Sserial display deviceconnecting, 82, 84recommended windows, 92setting parameters, 82, 83serverfront panel, 28service processor, 22Standby pow

Strany 4

Index101

Strany 5

Figures11Figure 1-1. 8-Socket Server Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Figure 1

Strany 6

Figures12Figure 2-32. The ls Command Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Figur

Strany 7

Figures13

Strany 8

Figures14

Strany 9

15About this DocumentThis document covers the HP Integrity rx7640 and HP 9000 rp7440 Servers.This document does not describe system software or parti

Strany 10

16Book LayoutThis document contains the following chapters and appendices:• Chapter 1 - Overview• Chapter 2 - Installing the Server

Strany 11

17Intended AudienceThis document is intended to be used by customer engineers assigned to support the HP Integrity rx7640 and HP 9000 rp7440 Servers.

Strany 12

18Related InformationYou can access other information on HP server hardware management, Microsoft® Windows® administratuon, and diagnostic support too

Strany 13

19CAUTION A caution provides information required to avoid losing data or avoid losing system functionality.NOTE A note highlights useful information

Strany 14

2Legal Notices © Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.The onl

Strany 15 - About this Document

20HP Encourages Your CommentsHewlett-Packard welcomes your feedback on this publication. Please address your comments to [email protected] and

Strany 16 - Book Layout

Chapter 1211 HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewThe HP Integrity rx7640 and HP 9000 rp7440 servers are members of HP’s busin

Strany 17 - Publishing History

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview22The information in this guide applies to the HP Integrity rx7640 and HP 9000 r

Strany 18 - Typographic Conventions

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description23Detailed Server DescriptionThe following section pr

Strany 19

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description24Dimensions and ComponentsThe following section desc

Strany 20 - HP Encourages Your Comments

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description25Figure 1-3 Server (Front View Without Bezel)The ser

Strany 21 - Chapter 1

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description26The mass storage section located in the front enabl

Strany 22

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description27The two hot-pluggable N+1 redundant bulk power supp

Strany 23 - Detailed Server Description

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description28Front PanelFront Panel Indicators and ControlsThe f

Strany 24 - Dimensions and Components

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description29Cell BoardThe cell board, illustrated in Figure 1-7

Strany 25

Contents31. HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description . . . . . . . . . . . . . . . . . . . . . . . .

Strany 26 - Display Board

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description30PDH Riser BoardThe PDH riser board is a small card

Strany 27 - MP/SCSI Core I/O

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description31Figure 1-8 CPU Locations on Cell BoardMemory Subsys

Strany 28

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description32The memory subsystem comprises four independent qua

Strany 29 - Cell Board

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description33Cells and nPartitionsAn nPartition comprises one or

Strany 30

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description34Internal Disk Devices for the ServerAs Figure 1-10

Strany 31

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description35The backplane also contains connectors for attachin

Strany 32 - Figure 1-9 Memory Subsystem

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description36Each LBA acts as a bus bridge, supporting either on

Strany 33 - Cells and nPartitions

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description37The server supports two internal SBAs. Each SBA pro

Strany 34 - System Backplane

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description38MP/SCSI BoardUp to two MP/SCSI cards can be plugged

Strany 35 - I/O Subsystem

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description39LAN/SCSI BoardAt least one LAN/SCSI board is requir

Strany 36

Contents4

Strany 37 - Table 1-4 PCI-X Paths Cell 1

Chapter 1HP Integrity rx7640 Server and HP 9000 rp7440 Server OverviewDetailed Server Description40

Strany 38 - Table 1-5 PCI-X Slot Types

Chapter 2412 Installing the ServerInspect shipping containers when the equipment arrives at the site. Check equipment after the packing has been remov

Strany 39

Chapter 2Installing the ServerReceiving and Inspecting the Server Cabinet42Receiving and Inspecting the Server CabinetThis section contains informatio

Strany 40

Chapter 2Installing the ServerReceiving and Inspecting the Server Cabinet43Step 2. Lift the cardboard top cap from the shipping box. Refer to Figure 2

Strany 41 - 2 Installing the Server

Chapter 2Installing the ServerReceiving and Inspecting the Server Cabinet44NOTE Figure 2-2 shows one ramp attached to the pallet on either side of the

Strany 42 - Unpacking the Server Cabinet

Chapter 2Installing the ServerReceiving and Inspecting the Server Cabinet45Step 6. Remove the six bolts from the base that attaches the rack to the pa

Strany 43

Chapter 2Installing the ServerReceiving and Inspecting the Server Cabinet46Securing the CabinetWhen in position, secure and stabilize the cabinet usin

Strany 44

Chapter 2Installing the ServerStandalone and To-Be-Racked Systems47Standalone and To-Be-Racked SystemsServers shipped in a stand-alone or to-be-racked

Strany 45

Chapter 2Installing the ServerLifting the Server Cabinet Manually48Lifting the Server Cabinet ManuallyUse this procedure only if no HP approved lift i

Strany 46 - Securing the Cabinet

Chapter 2Installing the ServerLifting the Server Cabinet Manually49Step 5. Insert the 2 protruding tabs on rear flange of handle into the slotted keyw

Strany 47

Contents5

Strany 48

Chapter 2Installing the ServerLifting the Server Cabinet Manually50Step 6. Align the screw holes in the handle’s front flange with the rack mounting h

Strany 49

Chapter 2Installing the ServerUsing the RonI Model 17000 SP 400 Lifting Device51Using the RonI Model 17000 SP 400 Lifting DeviceUse the lifter designe

Strany 50

Chapter 2Installing the ServerUsing the RonI Model 17000 SP 400 Lifting Device52Figure 2-7 RonI LifterStep 1. Obtain the HP J1530C Rack Integration Ki

Strany 51

Chapter 2Installing the ServerUsing the RonI Model 17000 SP 400 Lifting Device53Step 3. Insert the lifter forks between the cushions.Figure 2-8 Positi

Strany 52 - Figure 2-7 RonI Lifter

Chapter 2Installing the ServerUsing the RonI Model 17000 SP 400 Lifting Device54Step 5. Slowly raise the server off the pallet until it clears the pal

Strany 53

Chapter 2Installing the ServerWheel Kit Installation55Wheel Kit InstallationCompare the packing list (Table 2-1) with the contents of the wheel kit be

Strany 54

Chapter 2Installing the ServerWheel Kit Installation56Use the following procedure to install the wheel kit.Step 1. Cut and remove the polystrap bands

Strany 55 - Wheel Kit Installation

Chapter 2Installing the ServerWheel Kit Installation57Step 5. Carefully tilt the server and place one of the foam blocks (A6093-44002) under the left

Strany 56 - Bezel Kit

Chapter 2Installing the ServerWheel Kit Installation58Step 6. Carefully tilt the server and place the other foam block provided in the kit under the r

Strany 57

Chapter 2Installing the ServerWheel Kit Installation59Step 7. Remove the cushions from the lower front and rear of the server. Do not disturb the side

Strany 58

Contents6

Strany 59 - Table 2-2 Caster Part Numbers

Chapter 2Installing the ServerWheel Kit Installation60Step 9. Locate and remove one of the four screws from the plastic pouch. Attach the a caster to

Strany 60

Chapter 2Installing the ServerWheel Kit Installation61Step 16. Insert the slot on the caster cover into the front caster. Secure the cover to the serv

Strany 61 - Figure 2-16 Completed Server

Chapter 2Installing the ServerInstalling the Power Distribution Unit62Installing the Power Distribution UnitThe server may ship with a power distribut

Strany 62

Chapter 2Installing the ServerInstalling Additional Cards and Storage63Installing Additional Cards and StorageThis section provides information on add

Strany 63

Chapter 2Installing the ServerInstalling Additional Cards and Storage64Step 2. Slide the disk drive into the chassis, a slow firm pressure is needed t

Strany 64

Chapter 2Installing the ServerInstalling Additional Cards and Storage65Removable Media Drive InstallationThe DVD drive, or DAT tape drive is located i

Strany 65

Chapter 2Installing the ServerInstalling Additional Cards and Storage66PCI-X Card Cage Assembly I/O CardsThe server supports a number of PCI and PCI-X

Strany 66 - Windows® Linux®

Chapter 2Installing the ServerInstalling Additional Cards and Storage67B- Supports Mass Storage Bootb- Supports LAN BootBb- Supports Mass Storage and

Strany 67

Chapter 2Installing the ServerInstalling Additional Cards and Storage681. Factory integration (software load) of the OpenVMS, Windows, and Linux opera

Strany 68

Chapter 2Installing the ServerInstalling Additional Cards and Storage69• Obtain a copy of the interface card guide for instructions on preparing the o

Strany 69

Contents7

Strany 70 - Manual Release Latch Open

Chapter 2Installing the ServerInstalling Additional Cards and Storage70The green power LED will start to blink.Figure 2-19 PCI I/O Slot DetailsStep 7.

Strany 71 - PCI/PCI-X Cards

Chapter 2Installing the ServerInstalling Additional Cards and Storage71IMPORTANT If you are installing the A6869B in HP servers based on the sx1000 ch

Strany 72 - A6869B VGA/USB PCI Card

Chapter 2Installing the ServerInstalling Additional Cards and Storage727. Follow proper procedures to power-on the PCI power domain and boot the Wind

Strany 73 - Cabling and Power Up

Chapter 2Installing the ServerCabling and Power Up73Cabling and Power UpAfter the system has been unpacked and moved into position, it must be connect

Strany 74

Chapter 2Installing the ServerCabling and Power Up74Step 11. Measure the voltage between L1 and L2. This is considered to be a phase-to-phase measurem

Strany 75

Chapter 2Installing the ServerCabling and Power Up75WARNING SHOCK HAZARDRisk of shock hazard while testing primary power.Use properly insulated probes

Strany 76

Chapter 2Installing the ServerCabling and Power Up76Verifying the Safety Ground (Dual Power Source)Use this procedure to measure the voltage level bet

Strany 77

Chapter 2Installing the ServerCabling and Power Up774. Verify that the measurement is between 0-5 V AC.If the measurement is 5 V or greater, escalate

Strany 78 - Connecting AC Input Power

Chapter 2Installing the ServerCabling and Power Up78Step 4. Set the site power circuit breaker to ON.Figure 2-24 Wall Receptacle PinoutsWARNING SHOCK

Strany 79

Chapter 2Installing the ServerCabling and Power Up79NOTE When running the server with a single power source, either A0 and B0 or A1 and B1 should be u

Strany 80

Contents8

Strany 81 - Attach Straps

Chapter 2Installing the ServerCabling and Power Up80Figure 2-26 Distribution of Input Power for Each Bulk Power SupplyWARNING Voltage is present at va

Strany 82 - Core I/O Connections

Chapter 2Installing the ServerCabling and Power Up81Installing The Line Cord Anchor (for rack mounted servers)The line cord anchor is attached to the

Strany 83

Chapter 2Installing the ServerCabling and Power Up82Core I/O ConnectionsEach server can have up to two core I/O board sets installed which allows for

Strany 84

Chapter 2Installing the ServerCabling and Power Up83• Setting the MP LAN configurations• Shutting down cell board powerEstablish communication with th

Strany 85

Chapter 2Installing the ServerCabling and Power Up84If the CE Tool is a laptop using Reflection 1, ensure communications settings are in place, using

Strany 86 - Figure 2-30 MP Main Menu

Chapter 2Installing the ServerCabling and Power Up85On the front of the server, a solid green Power LED and a solid green MP Status LED will illuminat

Strany 87 - Do you want to modify it?

Chapter 2Installing the ServerCabling and Power Up86The MP Main Menu is displayed:Figure 2-30 MP Main MenuConfiguring LAN Information for the MPThis s

Strany 88 - CM to enter the Command Menu

Chapter 2Installing the ServerCabling and Power Up87The screen displays the default values and asks if you want to modify them. Write down the informa

Strany 89 - Figure 2-34 Browser Window

Chapter 2Installing the ServerCabling and Power Up88Step 10. A screen similar to the following is displayed, allowing verification of the settings:Fi

Strany 90

Chapter 2Installing the ServerCabling and Power Up89Step 4. Type SA at the MP:CM> prompt to display and set MP remote access.Figure 2-33 Example sa

Strany 91 - System Console Selection

Tables9Table 1-1. Cell Board CPU Module Load Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Table 1-2. Ser

Strany 92 - Booting the Server

Chapter 2Installing the ServerCabling and Power Up90Step 8. Select the emulation type you want to use.Step 9. Click anywhere on the Zoom In/Out title

Strany 93

Chapter 2Installing the ServerCabling and Power Up91System Console SelectionEach operating system requires that the correct console type be selected f

Strany 94

Chapter 2Installing the ServerCabling and Power Up92e. Select “Save Settings to NVRAM” and then “Exit” to complete the change.f. A system reset is req

Strany 95 - Installation Checklist

Chapter 2Installing the ServerCabling and Power Up93Step 1. A window showing all activity in the complex. Following the installation procedure in this

Strany 96 - Installing the Server

Chapter 2Installing the ServerCabling and Power Up94Step 5. Enter the console by typing co at the MP Main Menu.Exit the MP to return automatically to

Strany 97

Chapter 2Installing the ServerCabling and Power Up95CPU into an instantly ordered and fulfilled CPU upgrade that requires payment. After the Instant C

Strany 98

Chapter 2Installing the ServerCabling and Power Up96Unpack SPU cabinetAllow proper clearanceCut polystrap bandsRemove cardboard top capRemove corrugat

Strany 99

Chapter 2Installing the ServerCabling and Power Up97Connect customer console Set up network on customer consoleVerify LAN connection Verify presence o

Strany 100

Chapter 2Installing the ServerCabling and Power Up98Make entry in Gold Book (recommended)Customer acceptance and signoff (if required)Table 2-5 Factor

Strany 101

99IndexAac powervoltage check, 77ASIC, 22Bbackplanemass storage, 39PCI, 35, 39system, 27, 35, 38BPS (Bulk Power Supply), 85Ccell board, 26, 27, 29, 83