Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA
Product Specification: Model C200 - Capstone MicroTurbine
460045 Rev C (November 2008) Page 10 of 16
Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document
without incurring any obligation either with respect to equipment previously sold or in the process of construction.
Figure 4 presents the nominal rating and minimum/maximum net efficiency versus ambient
temperature (at sea level) for the C200 low pressure natural gas versions, including the
external heat recovery module in full bypass mode and inlet fuel pressure at .25 psig
(1.7 kPag).
C200 LPNG Net Efficiency vs. Ambient Temperature at Sea Level
0
5
10
15
20
25
30
35
40
0 102030405060708090100110120
Ambient Temperature [°F]
Net Efficiency [%]
Nominal
Minimum
Maximum
Figure 4. C200 Low Pressure Natural Gas Net Efficiency vs. Ambient Temperature
Note:
(1) Nominal Rating and Min/Max Net Efficiency vs. Ambient Temperature at Sea Level with Zero Back
Pressure for the C200 low pressure natural gas versions with inlet fuel pressure at .25 psig (1.7 kPag).
C200 Low Pressure
Natural Gas