© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-1
8
Reference
In this Chapter... Logging-On as service3070, 8-2
The Root Directory Environment Variable, 8-3
Directory Descriptions, 8-6
Editing Files, 8-8
MS Windows Quick-Reference, 8-16
BT-BASIC Quick-Reference, 8-17
NT Korn Shell Quick Reference, 8-18
vi and viw Editor Quick Reference, 8-21
Codewords, 8-25
System Config File Specifics, 8-26
Standard Config File Specifics, 8-29
Compiling the System and Standard Config Files, 8-35
The bootptab File, 8-36
The hosts File, 8-38
Device Files, 8-40
Vacuum Control, 8-42
Rotating the Testhead, 8-43
Testhead Cards, 8-44
DUT Power Supplies, 8-47
Controller Cables and Devices, 8-52
Testhead LAN and Serial Port MUX, 8-59
Referenced Manuals
The following manuals are referenced within this
chapter:
Administering Agilent 3070 MS Windows Systems
E9970-90000.
Agilent 3070 / 79000 Family Site Preparation
Manual 03066-90114.
Agilent 3070 / 79000 Repair I Manual
E4000-90160.
Agilent 3070 Family Users' Manual.
Introduction
The information in this chapter may be helpful when
installing an Agilent 3070 system that uses a MS
Windows controller.
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - Reference

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-1 8ReferenceIn this Chapter... Logging-On as servic

Strany 2 - Logging-On as

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-10Chapter 8: ReferenceHow to Resolve the Standard Confi

Strany 3 - Variable

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-11Chapter 8: ReferenceNo changes to the system config f

Strany 4 - ■ Use the correct case

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-12Chapter 8: Reference5 Copy the appropriate statement

Strany 5

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-13Chapter 8: Reference6 Paste the copied text in the s

Strany 6 - Descriptions

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-14Chapter 8: Reference8 Save , then exit the standard

Strany 7 - $AGILENT3070_ROOT\util

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-15Chapter 8: ReferenceFigure 8-1 Copying configuration

Strany 8 - Use BT-BASIC

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-16Chapter 8: ReferenceMS Windows Quick-ReferenceSee Tab

Strany 9 - Testhead Configuration

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-17Chapter 8: ReferenceBT-BASIC Quick-ReferenceTable 8-8

Strany 10 - System Config File

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-18Chapter 8: ReferenceNT Korn Shell Quick ReferenceAlth

Strany 11 - Chapter 8: Reference

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-19Chapter 8: ReferenceList files, and show directories

Strany 12

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-2Chapter 8: ReferenceLogging-On as service3070The servi

Strany 13

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-20Chapter 8: ReferenceExit / close Korn shell window ex

Strany 14

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-21Chapter 8: Referencevi and viw Editor Quick Reference

Strany 15 - BT-BASIC

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-22Chapter 8: ReferenceCursor to end of fileGCursor to l

Strany 16 - Quick-Reference

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-23Chapter 8: ReferenceMoving textJoin lines of textJCop

Strany 17

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-24Chapter 8: ReferenceRepairing mistakesUndo the previo

Strany 18 - NT Korn Shell Quick

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-25Chapter 8: ReferenceCodewords Codewords are pre-insta

Strany 19

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-26Chapter 8: ReferenceSystem Config File SpecificsThe p

Strany 20

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-27Chapter 8: ReferenceDescriptions of Some Statements i

Strany 21 - Quick Reference

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-28Chapter 8: ReferenceNOTESingle-density Hybrid Pin Car

Strany 22

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-29Chapter 8: ReferenceStandard Config File SpecificsThi

Strany 23

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-3Chapter 8: ReferenceThe Root Directory Environment Var

Strany 24

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-30Chapter 8: ReferenceStatements Allowed in the Standar

Strany 25 - Compile the Two Config Files

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-31Chapter 8: ReferenceSee Table 8-12 for 3X72 process t

Strany 26 - Specifics

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-32Chapter 8: ReferenceCAUTION!enable <keywords> s

Strany 27 - Config File

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-33Chapter 8: ReferencedrivethruEnables the testing of d

Strany 28 - <keywords>

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-34Chapter 8: ReferencetestjetEnables the TestJet testin

Strany 29 - File Specifics

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-35Chapter 8: ReferenceCompiling the System and Standard

Strany 30

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-36Chapter 8: ReferenceThe bootptab File This section co

Strany 31

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-37Chapter 8: Reference5 If a ControlXT Card was remove

Strany 32

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-38Chapter 8: ReferenceThe hosts File The path to the ho

Strany 33

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-39Chapter 8: ReferenceExample 8-1 A sample hosts file##

Strany 34

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-4Chapter 8: ReferenceUse of the Root Directory Environm

Strany 35 - System and

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-40Chapter 8: ReferenceDevice Files This section contain

Strany 36 - Hardware Addresses

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-41Chapter 8: ReferenceDUT Power Supply Device FilesSee

Strany 37 - IP Addresses

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-42Chapter 8: ReferenceVacuum Control Location of Vacuum

Strany 38 - Test Device Communication

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-43Chapter 8: ReferenceRotating the TestheadCAUTION!Remo

Strany 39

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-44Chapter 8: ReferenceTesthead Cards See Table 8-15 for

Strany 40 - Location of Device Files

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-45Chapter 8: ReferenceH_StdDD2 hybrid standard double d

Strany 41 - DUT Power Supply Device Files

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-46Chapter 8: ReferenceSTC_B serial b revision 6/12/20 E

Strany 42 - Vacuum Control Specifics

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-47Chapter 8: ReferenceDUT Power SuppliesVoltage RangesD

Strany 43 - Testhead

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-48Chapter 8: ReferenceThe commented ("!") sta

Strany 44

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-49Chapter 8: ReferenceGPIB Addresses and Device FilesIf

Strany 45 - /var/hp3070/bin/.enable file

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-5Chapter 8: ReferenceUse of the Root Directory Environm

Strany 46

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-50Chapter 8: ReferenceModule 3, asru channel 5 or 5-6 3

Strany 47 - Supplies

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-51Chapter 8: ReferenceTo Change DUT Power Supply GPIB A

Strany 48

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-52Chapter 8: ReferenceController Cables and DevicesTher

Strany 49

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-53Chapter 8: ReferenceFigure 8-2 Kayak XU700 cabling di

Strany 50 - Module 3, asru channel 6 4

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-54Chapter 8: ReferenceTable 8-19 Kayak XU700 cables and

Strany 51

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-55Chapter 8: ReferenceN E4000-61629 LAN Cable, SMB to S

Strany 52 - Controller Cables

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-56Chapter 8: ReferenceFigure 8-3 Visualize P600C cablin

Strany 53

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-57Chapter 8: ReferenceTable 8-20 Visualize P600C cables

Strany 54

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-58Chapter 8: ReferenceN E4000-61629 LAN Cable, SMB to S

Strany 55

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-59Chapter 8: ReferenceTesthead LAN and Serial Port MUXT

Strany 56 - Workstation

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-6Chapter 8: ReferenceDirectory DescriptionsTable 8-4 li

Strany 57

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-60Chapter 8: ReferenceTable 8-21 Connector box MUX assi

Strany 58

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-7Chapter 8: Reference$AGILENT3070_ROOT\tmpA directory t

Strany 59 - Serial Port MUX

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-8Chapter 8: ReferenceEditing Files This section contain

Strany 60

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-9Chapter 8: ReferenceOpen BT-BASIC• Double-click the de

Komentáře k této Příručce

Žádné komentáře