HP ML330 - ProLiant - G3 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Barebones pro PC / pracovní stanice HP ML330 - ProLiant - G3. HP ML330 - ProLiant - G3 Specifications [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP ProLiant ML330 Generation 3 Server
Maintenance and Service Guide
January 2004 (Fourth Edition)
Part Number 322375-004
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - Part Number 322375-004

HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide January 2004 (Fourth Edition) Part Number 322375-004

Strany 2

Illustrated Parts Catalog Table 1-1: Mechanical Components Item Description Spare Part Number Chassis 1 Front bezel 324713-001 2 Access panel

Strany 3 - Contents

Illustrated Parts Catalog System Components HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 1-3

Strany 4

Illustrated Parts Catalog Table 1-2: System Components Item Description Spare Part Number Mass Storage Devices 5 IDE CD-ROM drive, 48X 288894-

Strany 5

Illustrated Parts Catalog HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 1-5 Table 1-2: System Components continued Item Descr

Strany 6

2 Removal and Replacement Procedures To service the server, you might need the following: • • • • • • • • • • • • Torx T-15 screwdriver Flat-blade scr

Strany 7 - About This Guide

Removal and Replacement Procedures Rack Warnings and Cautions WARNING: Because the rack allows stacking of computer components on a vertical rather

Strany 8 - Telephone Numbers

Removal and Replacement Procedures WARNING: Be sure that the AC power supply branch circuit that provides power to the rack is not overloaded. Not

Strany 9 - Illustrated Parts Catalog

Removal and Replacement Procedures System Power Down WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, re

Strany 10

Removal and Replacement Procedures Front Bezel CAUTION: To prevent equipment damage or data loss, be sure that the server is powered down, all cabl

Strany 11 - System Components

Removal and Replacement Procedures Bezel Blanks WARNING: To reduce the risk of personal injury and to prevent damage to the equipment, before remov

Strany 12

© 2003, 2004 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. Int

Strany 13

Removal and Replacement Procedures Access Panel WARNING: To reduce the risk of injury from hot surfaces, allow the drives and the internal system c

Strany 14 - Safety Considerations

Removal and Replacement Procedures Air Baffle To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2. Re

Strany 15 - Server Warnings and Cautions

Removal and Replacement Procedures DIMMs To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2. Remove

Strany 16

Removal and Replacement Procedures Processor and Heatsink/Fan Assembly CAUTION: To reduce the risk of personal injury from hot surfaces, allow the

Strany 17 - System Power Down

Removal and Replacement Procedures 13. Remove the heatsink/fan assembly. 14. Open the processor socket locking lever and remove the processor. To re

Strany 18 - Front Bezel

Removal and Replacement Procedures Processor Retention Brackets To remove the components: 1. Power down the server. Refer to “System Power Down” in t

Strany 19 - Bezel Blanks

Removal and Replacement Procedures System Fan To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2. Re

Strany 20 - Access Panel

Removal and Replacement Procedures 6. Remove the system fan: a. Use a Torx T-15 screwdriver to remove the four mounting screws from the rear of the

Strany 21 - Air Baffle

Removal and Replacement Procedures Power Supply WARNING: To reduce the risk of electric shock or damage to the equipment: • Unplug the power cord

Strany 22

Removal and Replacement Procedures Media Devices Cable Routing Diagrams SCSI Device Cabling NOTE: Air baffle removed for clarity. 2-16 HP ProLiant

Strany 23

Contents About This Guide Audience Assumptions...

Strany 24

Removal and Replacement Procedures ATA Device Cabling NOTE: Air baffle removed for clarity. Table 2-1: ATA Cabling Routing Item Channel/Cable Ca

Strany 25 - Processor Retention Brackets

Removal and Replacement Procedures ATAPI Tape Drive Cabling NOTE: Air baffle removed for clarity. Table 2-2: ATAPI Tape Drive Cable Routing Item

Strany 26 - System Fan

Removal and Replacement Procedures CD-ROM Drive To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2.

Strany 27

Removal and Replacement Procedures Media Bay Drive Tray NOTE: The drive trays in the removable media bays can be used to mount internal 3.5-inch dev

Strany 28 - Power Supply

Removal and Replacement Procedures Hard Drive Compartment To remove the component: 1. Power down the server. Refer to “System Power Down” in this cha

Strany 29 - Media Devices

Removal and Replacement Procedures Diskette Drive To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2.

Strany 30 - ATA Device Cabling

Removal and Replacement Procedures Hard Drives To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2. R

Strany 31 - ATAPI Tape Drive Cabling

Removal and Replacement Procedures ATA Drive Failure Scenarios IMPORTANT: This section applies only to ATA models of the server. When a drive fails:

Strany 32 - CD-ROM Drive

Removal and Replacement Procedures When an online spare is not configured, you must rebuild the array. To rebuild the array: 1. Replace the failed dr

Strany 33 - Media Bay Drive Tray

Removal and Replacement Procedures Array Information The Array Information window of the setup screen displays all configured drive arrays. Use this s

Strany 34 - Hard Drive Compartment

Contents System Board...

Strany 35 - Diskette Drive

Removal and Replacement Procedures — Stripe Size—changes the stripe size. This field applies only to RAID 0 arrays. The default stripe size is 64 KB.

Strany 36 - Hard Drives

Removal and Replacement Procedures Removable Media Bay Devices To remove the component: 1. Power down the server. Refer to “System Power Down” in thi

Strany 37

Removal and Replacement Procedures Power Button/LED Assembly To remove the component: 1. Power down the server. Refer to “System Power Down” in this

Strany 38

Removal and Replacement Procedures 5. Remove the LED shield: a. Press the locking levers. b. Pull the shield away from the chassis. 2-30 HP ProLi

Strany 39

Removal and Replacement Procedures 6. Disengage the power button: a. From the front of the chassis, squeeze the sides of the power button to disenga

Strany 40

Removal and Replacement Procedures SCSI Controller To remove the component: 1. Power down the server. Refer to “System Power Down” in this chapter. 2

Strany 41 - Removable Media Bay Devices

Removal and Replacement Procedures Expansion Slot Retainer To remove the component: 1. Power down the server. Refer to “System Power Down” in this ch

Strany 42 - Power Button/LED Assembly

Removal and Replacement Procedures Battery If the server no longer automatically displays the correct date and time, you may need to replace the batte

Strany 43 - 5. Remove the LED shield:

Removal and Replacement Procedures IMPORTANT: Positive (+) polarity must be positioned up. IMPORTANT: Replacing the system board battery resets th

Strany 44

Removal and Replacement Procedures 10. Remove the system board: a. Remove the nine screws securing the system board to the chassis. b. Slide the sys

Strany 45 - SCSI Controller

Contents Integrated Dual Channel Ultra ATA/100 Adapter with Integrated ATA RAID 0, 1, and 1+0 (ATA Models)...

Strany 46 - Expansion Slot Retainer

Removal and Replacement Procedures HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 2-37 Re-entering the Server Serial Number Afte

Strany 47 - Battery

3 Diagnostic Tools Automatic Server Recovery-2 ASR-2 is a feature that causes the system to restart when a catastrophic operating system error occurs,

Strany 48 - System Board

Diagnostic Tools • Multiple drive rebuilding • • • • • • • • • • • Special handling of error log, spare drive, and rebuilding After all hard drives h

Strany 49

Diagnostic Tools Management Agents The server is equipped with the latest Management Agents, allowing easy manageability of the server through Insight

Strany 50

Diagnostic Tools To make selections within RBSU, use the following keys: • • • • • Access RBSU by pressing the F9 key when prompted during startup. Us

Strany 51 - Diagnostic Tools

Diagnostic Tools To install the SmartStart software: 1. Press the F9 key to run RBSU and configure the primary operating system. 2. Locate the Smart

Strany 52 - Integrated Management Log

Diagnostic Tools 3-6 HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide • • • • Survey Utility Survey Utility gathers critical hardw

Strany 53 - ROM-Based Setup Utility

4 Component Identification Front Panel Components Table 4-1: Front Panel Components Item Description 1 CD-ROM drive eject button 2 Diskette drive

Strany 54 - SmartStart Software

Component Identification Front Panel LEDs Table 4-2: Front Panel LEDs Item LED Description Status 1 CD-ROM drive activity 2 Diskette drive activi

Strany 55 - SmartStart Scripting Toolkit

Component Identification Media Components Table 4-3: Media Components Item Description Location Dimensions 1 IDE CD-ROM drive Media bay 1 2 Av

Strany 57 - Component Identification

Component Identification Rear Panel Components Table 4-4: Rear Panel Components Item Description 1 Power connector 2 Mouse connector 3 Keyboard con

Strany 58 - Front Panel LEDs

Component Identification Rear Panel LEDs Table 4-5: Rear Panel LEDs Item LED Description Status 1 Network activity Flashing green = Network activ

Strany 59 - Media Components

Component Identification System Board Components Table 4-6: System Board Components Item Description Item Description 1 Power supply connectors

Strany 60 - Rear Panel Components

Component Identification System Configuration Switch CAUTION: Clearing nonvolatile RAM (NVRAM) deletes the system configuration. For instructions o

Strany 61 - Rear Panel LEDs

Component Identification System ID Switch The system ID switch is reserved for use by authorized service providers only. Do not change the indicated d

Strany 62 - System Board Components

Component Identification System Board LEDs Table 4-8: System Board LEDs Item LED Description Status 1 System fan failure Amber = The system fan

Strany 63 - System Configuration Switch

Component Identification Table 4-8: System Board LEDs continued Item LED Description Status 12 Processor fan 2 failure Amber = Processor fan 2 has

Strany 64 - Jumper Settings

Component Identification SCSI Cable Components Before performing SCSI cabling procedures, identify the SCSI cable components. The SCSI cable supports

Strany 65 - System Board LEDs

Component Identification 4-12 HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide ATA Cable Components Before performing ATA cabling

Strany 66 - SCSI Controller Components

5 Specifications Server Unit Table 5-1: Server Unit Specifications Specification Value Dimensions Height 42.7 cm (16.8 in) Width 19.1 cm (7.5 in)

Strany 67 - SCSI Cable Components

About This Guide This maintenance and service guide can be used for reference when servicing the HP ProLiant ML330 Generation 3 server. WARNING: T

Strany 68 - ATA Cable Components

Specifications Environmental Specifications Table 5-2: Environmental Specifications Specification Value Temperature range* Operating 50°F to 95°F

Strany 69 - Specifications

Specifications Diskette Drive Table 5-4: 1.44-MB Diskette Drive Specifications Specification Value Size 8.89 cm (3.5 in) LEDs (front panel) Green

Strany 70 - Environmental Specifications

Specifications Table 5-5: IDE CD-ROM Specifications continued Specification Value Dimensions Height 42.9 mm (1.69 in) Width 208.0 mm (8.2 in) Dept

Strany 71 - IDE CD-ROM Drive

Specifications ATA Hard Drives Table 5-6: ATA Hard Drive Specifications Specification 40 GB 7.2K rpm 80 GB 7.2K rpm 160 GB 7.2K rpm Capacity

Strany 72

Specifications Wide Ultra3 SCSI Hard Drives Table 5-7: Wide Ultra3 SCSI Hard Drive Specifications Specification 18.2 GB 10 K rpm 36.4 GB 10 K rpm

Strany 73 - ATA Hard Drives

Specifications NC7760 PCI Gigabit Server Adapter (Integrated/Embedded) Table 5-8: NC7760 PCI Gigabit Server Adapter (Integrated/Embedded) Specificat

Strany 74 - Wide Ultra3 SCSI Hard Drives

Specifications 5-8 HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide Integrated Dual Channel Ultra ATA/100 Adapter with Integrated

Strany 75

Index A C AC power LEDs 4-10 cable clips, part number 1-2 access panels cable routing diagrams airflow caution 2-7 ATA cable routing 2-17

Strany 76

Index D H devices, jumper settings 4-8 hard drive diagnostic tools 3-1 ATA, specifications 5-5 diagnostics utility 2-1, 3-5 bays 4-3 DIM

Strany 77

Index L power switch See power button/LED assembly; Power On/Standby button LED shield powering down the server 2-4 part number 1-2 Power-On Sel

Strany 78

About This Guide CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the ser

Strany 79

Index Index-4 HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide rubber bumpers, part number 1-2 S safety considerations 2-1 SCS

Strany 80

1 Illustrated Parts Catalog Mechanical Components HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 1-1

Komentáře k této Příručce