1657 RLC Digibridge®
Instruction Manual
Foun 1657-0120-07/B1
®QuadTech, Inc., 1992
5 Clock Tower Place, 210 East
Maynard, Massachusetts, U.S.A. 01754
January, 1997
Tel. 978-461-2100
800-253-1230 (Sales)
800-253-1230 (Service)
Fax. 978-461-4295
The material in this manual is for informational purposes only and is subject to change, without notice.
QuadTech assumes no responsibility for any error or for consequential damages that may result from the
misinterpretation of any procedures in this publication.
Contents
Instruction Manual Changes
Specifications
Warranty
Introduction -Section 1
Installation -Section 2
Operation -Section 3
Theory -Section 4
Service and Maintenance -Section 5
Parts Lists and Diagrams -Section 6
~ Product will be marked with this symbol (ISO#3684) when it is necessary for the user to refer
to the instruction manual in order to prevent injury or equipment damage.
Zobrazit stránku 0
1 2 3 4 5 6 ... 56 57

Shrnutí obsahu

Strany 1 - Instruction Manual

1657 RLC Digibridge®Instruction ManualFoun 1657-0120-07/B1®QuadTech, Inc., 19925 Clock Tower Place, 210 EastMaynard, Massachusetts, U.S.A. 01754Januar

Strany 2

1-4 INTRODUCTION

Strany 3

2.1 UNPACKING AND INSPECTION.If the shipping carton is damaged, ask that the carrier'sagent be present when the instrument is unpacked. Inspect t

Strany 4

If your line voltage is in the higher range selectable by the line voltageswitch, use a power cord of the proper rating (250 V, 15 A) that mateswith b

Strany 5 - SERVICE POLICY

P-(potential, low) = Black/whiteI-(current, low) = BlackP+(potential, high) = Red/whiteI+(current, high) = RedGuard = Black/green2.5.4 The 1688-9600 E

Strany 6 - Table of Contents

b. Connect a suitable bias voltage source (see below)in series with the 1+ connection, basically as shown inthe diagram, with the following details.Wi

Strany 7

OPERATION 3-1

Strany 8 - 1-2 INTRODUCTION

3.1 BASIC PROCEDURE. Figure 3-1.For initial familiarization, follow this procedure carefully. For details, refer to later paragraphs in Operation.a. B

Strany 9 - INTRODUCTION 1-3

3.2 CONNECTION OF THE DUT.3.2.1 The Integral Test Fixture.The test fixture provided on the front ledge of the Digibridge provides convenient, reliable

Strany 10 - 1-4 INTRODUCTION

Each basic range is slightly more than 2 decades wide, from an R LCdisplay of 01900, with an automatic decimalpoint change between the decades, to 199

Strany 11

Figure 3-2. R L C basic accuracy as a percent of reading. Heavy lines (solid and dotted) represent bestchoice of range. Range 2 is dotted. Notice that

Strany 12

These two supplementary pages contain information of improvements or modifications notdocumented in the current manual. All references to GenRad in th

Strany 13

The logarithmic scales on these figures make it very easy to apply theaccuracy factors visually. For example, suppose a capacitor is being measuredon

Strany 14

3.5.4 Equivalent Series R for Capacitors.The total loss of a capacitor can be expressed in several ways, includingD and "ESR." To obtain equ

Strany 15 - OPERATION 3-1

WARNINGTo minimize shock hazard, limit bias to 30 V. Bias voltage is present at connectors, testfixtures and on capacitors under test.Capacitors remai

Strany 16

4.1 INTRODUCTION.4.2 PRINCIPAL FUNCTIONS.4.1 INTRODUCTION.4.1.1 General.This instrument uses an unusual method of measurement, which is quitedifferent

Strany 17

4-2 THEORY

Strany 18

4.2.2 Frequency and Time Source. Figure 4-3.A necessary standard for accuracy is the frequency of the test signal; andequally important are the genera

Strany 19

5.1 CUSTOMERSERVICE... 5-15.2 INSTRU

Strany 20

5.1 CUSTOMER SERVICE.Our warranty (at the front of this manual) attests the quality ofmaterials and workmanship in our products. Ifmalfunction does oc

Strany 21

1. Instrument description: name and catalog and serialnumbers. Refer to front and rear panels.2. Part number of board. Refer to the parts lists in thi

Strany 22

Insignificant figures. The right-hand digit(s) of the display normally flickerand change if they are not significant for the specified accuracy of the

Strany 23 - 'Patent applied for

Page 2-1 -Power-Line ConnectionPower line switch for 115V or 230V operation has been removed, switching isautomatic for voltages between 90 -250V AC.P

Strany 25

5.5.2 Resistance Measurement Accuracy.a. Set the line voltage switch, connect the powercord, and depress the POWER button. Allow 5 minutes for warm-up

Strany 26

box. (Be sure this is not strapped to G.) Connect cable tip G to G of theresistance box and to the outer terminals of the capacitance box.b. Follow ch

Strany 27

5.6.1 Disassembly. Figures 5-1 through 5-6.Use the following procedure for access to replaceableparts and contact points used in trouble analysis.a. D

Strany 28 - 5-2 SERVICE

d. Remove the ribbon cable (1657-0200) from power supply (at V-J1)and main board (at C-J1). Notice that the connectors are symmetrical andreversible;

Strany 29

Screw K must contact etched-circuit ground. A washer is supplied(under screw head) if necessary to do so.5.6.2 Access. Figures 5-7 and 5-8.Interior lo

Strany 30 - 5-4 SERVICE

5.6.3 Reference Designations.Refer to Section 6 for an explanation of these designations.For example, V- T1 designates transformer number one in thepo

Strany 31

a mild glass cleaner, such as "Windex" (Drackett Products Co., Cincinnati,Ohio). Do NOT use a paper towel; do NOT use enough liquid to drip

Strany 32

5.8.2 Power Supply.Check the power supply (V assembly) if there is a massive failure(nothing works) or as a starting procedure in any thorough analysi

Strany 33 - SERVICE 5-7

they will fit the socket directly.) Check at U12 pin 4 for a1-kHz noisy sine wave, 0.4 V pk-pk. If this is verified butstep g is not, fault is in U18.

Strany 34

Environment: TEMPERATURE: 0° to 50°C operating, -40° to +75°Cstorage. HUMIDITY: 0 to 85% R.H., operating.Supplied: Power cord, axial-lead adaptors, in

Strany 35

p. While monitoring U14 pin 2, push the FREQUENCY pushbutton andselect 120 Hz, (or 100 Hz). Check thatthe monitored signal (which should always be 256

Strany 36

Also, the amplitudes of the staircases depend on the RANGE selectedand the impedance components of the DUT. The chosen conditionsmake 1 staircase tall

Strany 37

5-16 SERVICE

Strany 38

a. Look at the following control signals with a scopeand compare them with the timing diagram:PBST, at C-U33 pin 10;PMSR, at U33 pin 12.If they are no

Strany 39

c. If the feedback signals are present, look at each of the followingcontrol signals and compare it with the timing diagram: (The first 4 signalshave

Strany 40

Parts Lists and Diagrams- Section 66.1 GENERAL . . . . . . . . . . . . . . . . .6.2 REFERENCE DESIGNATIONS . . . . . . . . . .6.3 DIAGRAMS. . . . . .

Strany 42 - 5-16 SERVICE

Mk:L;tlANIC;ALFRONT CFigure 6-l 1 _ItemDescriptionden Rad Part MftrMftr Part No.___---------------------------------------1,,,-,,---,,----------------

Strany 43 - ""

code00136o-3192co19400327004340665603779Olooo01121012660,261012950162601930019630211102114izi02660027350276603042OS5080355003636038770388803911zz04713

Strany 45

SERVICE POLICYQuadTech policy is to maintain product repair capability for a period of five (5) years after originalshipment and to make this capabili

Strany 54

Table of Contents

Strany 55

1.1 PURPOSE 1-11.2 GENERAL DESCRIPTION 1-11.3 CONTROLS, INDICATORS, AND CONNECTORS 1-11.4 ACCESSORIES 1-11.1 PURPOSE. in keeping with the long-life

Strany 56

1-2 INTRODUCTION

Strany 57

INTRODUCTION 1-3