Strany 1 - Part Number 356698-003

HP ProLiant ML350 Generation 4 Server Maintenance and Service Guide August 2005 (Third Edition) Part Number 356698-003

Strany 2 - Audience assumptions

Removal and replacement procedures 10 These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of p

Strany 3 - Contents

Removal and replacement procedures 11 Powering down the server WARNING: To reduce the risk of personal injury, electric shock, or damage to the e

Strany 4 - Contents 4

Removal and replacement procedures 12 Access Panel To remove the component from a rack server: 1. Power down the server ("Powering down the se

Strany 5 - Illustrated parts catalog

Removal and replacement procedures 13 Removing tower feet Remove the feet. Removing the front bezel (tower model) This server has a removable fron

Strany 6 - System Components

Removal and replacement procedures 14 1. Use a flat-head screwdriver to lift the spring tab. 2. Slide the rail forward and remove it from the serve

Strany 7

Removal and replacement procedures 15 2. Push down on the power supply release latch, and remove the power supply from the server. CAUTION: To p

Strany 8 - Safety considerations

Removal and replacement procedures 16 3. Remove the four screws from the chassis, and remove the power supply from the server. CAUTION: To preve

Strany 9 - Symbols on equipment

Removal and replacement procedures 17 Removing a hard drive blank To remove a hard drive blank, push the lever to release the blank and pull out.

Strany 10 - Preparation procedures

Removal and replacement procedures 18 To replace the component, reverse the procedure. Non-hot-plug SCSI hard drive CAUTION: To prevent improper

Strany 11 - Powering down the server

Removal and replacement procedures 19 2. Install two screws on the side of the hard drive to ensure proper alignment inside the bay. 3. Replace th

Strany 12 - Access Panel

© Copyright 2004, 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strany 13 - Rack rails

Removal and replacement procedures 20 Expansion Slot Cover To remove the component: 1. Remove the access panel ("Access Panel" on page 12

Strany 14 - Hot-plug power supply

Removal and replacement procedures 21 2. Remove the expansion board retainer. 3. Disconnect any internal or external cables from the expansion boa

Strany 15 - Non-hot-plug power supply

Removal and replacement procedures 22 3. Push up on the release lever and push the drive partially out through the front of the server. 4. Remove

Strany 16

Removal and replacement procedures 23 Internal two-bay hot-plug SCSI drive cage To remove the component: 1. Remove the access panel ("Access P

Strany 17 - Removing a hard drive blank

Removal and replacement procedures 24 Processor and Heatsink IMPORTANT: If upgrading processor speed, update the system ROM before installing the

Strany 18 - Non-hot-plug SCSI hard drive

Removal and replacement procedures 25 5. Open the processor locking lever and remove the processor. To replace the processor and heatsink: 1. Open

Strany 19 - Redundant system fan

Removal and replacement procedures 26 IMPORTANT: Do not remove the thermal tape from the bottom of the heatsink. Removing the tape will affect th

Strany 20 - Expansion board

Removal and replacement procedures 27 4. Close the processor retaining brackets. 5. Connect the heatsink connector to the correct header on the sy

Strany 21 - CD-ROM drive

Removal and replacement procedures 28 NOTE: PPM 1 is embedded onto the system board. NOTE: The appearance of compatible PPMs may vary. To rep

Strany 22 - Tape drive

Removal and replacement procedures 29 Duplex SCSI backplane To remove the component: 1. Remove the access panel ("Access Panel" on page 1

Strany 23

Contents 3 Contents Illustrated parts catalog ...

Strany 24 - Processor and Heatsink

Removal and replacement procedures 30 • Do not attempt to recharge the battery. • Do not expose the battery to temperatures higher than 60°C (140

Strany 25

Removal and replacement procedures 31 5. Remove the four system board screws, and remove the system board. To replace the component, reverse the re

Strany 26 - Install the heatsink

Diagnostic tools 32 Diagnostic tools In this section Automatic Server Recovery...

Strany 27

Diagnostic tools 33 • From within Survey Utility • From within operating system-specific IML viewers • For NetWare: IML Viewer • For Windows®: IM

Strany 28 - Second serial port

Diagnostic tools 34 ROM-Based Setup Utility RBSU, an embedded configuration utility, performs a wide range of configuration activities that may incl

Strany 29 - Battery

Diagnostic tools 35 • Installing optimized server drivers, management agents, and utilities automatically with every assisted installation • Testin

Strany 30 - System Board

Server component identification 36 Server component identification In this section Front Panel Components...

Strany 31

Server component identification 37 Front Panel LEDs and Buttons Item Description Status 1 UID LED Blue = Activated Flashing = System remotely

Strany 32 - Diagnostic tools

Server component identification 38 Rear Panel Components NOTE: Hot-plug power supply model shown. For non-hot-plug models, the power supply will l

Strany 33

Server component identification 39 Rear Panel LEDs Location LED Status 1 Power supply LED Off = No power or inadequate power supply Green = Po

Strany 34 - SmartStart software

Contents 4 SmartStart software...

Strany 35 - HP Insight Diagnostics

Server component identification 40 System Board Components NOTE: PPM 1 is embedded onto the system board. Item Description Item Description

Strany 36 - Front Panel Components

Server component identification 41 NMI jumper The NMI jumper allows administrators to perform a memory dump before performing a hard reset. Crash dum

Strany 37 - Front Panel LEDs and Buttons

Server component identification 42 System LED and Color Internal Health LED Color Status Processor failure, socket X (Amber) Red One or more of the

Strany 38 - Rear Panel Components

Server component identification 43 System Board LEDs Item LED Description Status 1 AC power Off = No AC power or failed power supply Green =

Strany 39 - Rear Panel LEDs

Server component identification 44 Item LED Description Status 14 DIMM 1 status Off = DIMM 1 functioning Amber = DIMM 1 failed Hot-Plug SCSI IDs

Strany 40 - System Board Components

Server component identification 45 Hot-plug SCSI hard drive LEDs Item LED description Status 1 Activity status On = Drive activity Flashing =

Strany 41 - System Maintenance Switch

Specifications 46 Specifications In this section Server Specifications ...

Strany 42

Specifications 47 Specification Value Rated steady-state power 460 W Maximum peak power 484 W Acoustic Noise Idle <6.5 and 48

Strany 43 - System Board LEDs

Specifications 48 Specification Value Input requirements Rated input voltage 100 VAC to 240 VAC Rated input frequency 47 Hz to 63 Hz

Strany 44 - Hot-Plug SCSI IDs

Specifications 49 Specification Value High 500 Kb/s Low 250 Kb/s Bytes/sector 512 Sectors per track (high/low) 18/9 Tracks per side (high/low) 80/8

Strany 45

Illustrated parts catalog 5 Illustrated parts catalog In this section Mechanical Components...

Strany 46 - Specifications

Specifications 50 Specification Value Laser parameters Type Semiconductor laser GaAs Wave length 700 ± 25 nm Divergence angle 53.5° ± 1.5° Output

Strany 47 - Rack server specifications

Acronyms and abbreviations 51 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility ASR Aut

Strany 48

Acronyms and abbreviations 52 ISEE Instant Support Enterprise Edition MPS multi-processor specification NEMA National Electrical Manufacturers Ass

Strany 49 - CD-ROM drive specifications

Acronyms and abbreviations 53 PXE preboot eXecution environment RBSU ROM-Based Setup Utility RILOE II Remote Insight Lights-Out Edition II SCSI

Strany 50

Index 54 A access panel 12 Altiris Deployment Solution 33 Altiris eXpress Deployment Server 33 ASR (Automatic Server Recovery) 32, 51 Automat

Strany 51 - Acronyms and abbreviations

Index 55 P PCI Express 38 power LEDs, system 37 Power On/Standby button 11, 36, 37 power requirements 48 power supplies 15, 48 power supply

Strany 52

Illustrated parts catalog 6 System Components Item Description Spare Part Number System Components 10 Fan assembly, 120 mm 367637-001 11 3

Strany 53

Illustrated parts catalog 7 Item Description Spare Part Number 23 Power switch 292236-001 24 Plastics kit* 250843-001 25 Country kit* 366859-00

Strany 54 - Index 54

Removal and replacement procedures 8 Removal and replacement procedures In this section Required Tools ....

Strany 55 - Index 55

Removal and replacement procedures 9 Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to foll