To eliminate the need for a protective enclosure, one may achieve Div 2 compliance by
using a suitable barrier(s) as described in Drawing K750525/K750531. To eliminate the
need for a protective enclosure or suitable barrier and still be Div 2 compliant, the conduit
adapter model (suffix C) along with properly rated and sealed conduit should be used.
Only pigtail models with electrical connection suffixes P, N or C are rated as Type
4X/IP56
For all safety locations, proper wiring and installation is critical. Installation must be
performed by licensed installers, under jurisdiction of local authorities. The safety
approvals are voided by modifications or non factory repairs to the HPT 100.