HP ProLiant DL560 Gen8 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 696744-003
February 2014
Edition: 3
Zobrazit stránku 0
1 2 3 4 5 6 ... 101 102

Shrnutí obsahu

Strany 1 - User Guide

HP ProLiant DL560 Gen8 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage

Strany 2

Component identification 10 9 iLO connector 10 Serial connector 11 FlexibleLOM ports (Shown: 4x1Gb/Optional: 2x10Gb); port 1 on right side Rear pa

Strany 3 - Contents

Index 100 A AC power supply 86 access panel 20 Advanced ECC memory 42, 44, 75 air baffle 23, 24 Array Configuration Utility (ACU) 76 ASR (

Strany 4 - Contents 4

Index 101 H hard drive bays 6, 14 hard drive LEDs 14 hard drives, determining status of 14 hardware options installation 30, 34 health drive

Strany 5 - Contents 5

Index 102 registering the server 33 regulatory compliance notices 84 removing a hot-plug SAS hard drive 45 removing the access panel 20 reta

Strany 6 - Component identification

Component identification 11 Slot PCIe 3-slot riser cage* PCIe 2-slot x16 riser cage 6 - HL/FH PCIe2 or PCIe3** x8 (8,4,2,1) — *Depending on the

Strany 7 - Systems Insight Display LEDs

Component identification 12 Item Description 4 Drive cage power connector 2 5 Processor 3 DIMM slots (1-6) 6 Systems Insight Display connector 7 Si

Strany 8

Component identification 13 Position Default Function S6 Off Off = No function On = ROM reads system configuration as invalid. S7 — Reserved S8

Strany 9 - Rear panel components

Component identification 14 DIMM slot locations DIMM slots are numbered sequentially (1 through 12) for each processor. The supported AMP modes use

Strany 10 - Rear panel LEDs and buttons

Component identification 15 Item LED Status Definition 1 Locate Solid blue The drive is being identified by a host application. Flashin

Strany 11 - System board components

Component identification 16 FBWC module LEDs (P222, P420, P421) The FBWC module has three single-color LEDs (one amber and two green). The LEDs are

Strany 12 - System maintenance switch

Component identification 17 CAUTION: To avoid damage to server components, all fan modules must be installed in fan bays for any processor configu

Strany 13 - NMI functionality

Operations 18 Operations Power up the server To power up the server, press the Power On/Standby button. Power down the server Before powering down

Strany 14 - Hot-plug drive bay numbering

Operations 19 2. Extend the server from the rack. 3. After performing the installation or maintenance procedure, slide the server back into the ra

Strany 15 - PCIe riser cage LED

© Copyright 2012, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only war

Strany 16 - Hot-plug fans

Operations 20 2. After the display fully ejects, rotate the display sideways to view the LEDs. Remove the access panel WARNING: To reduce the

Strany 17 - Component identification 17

Operations 21 3. Use a T-15 Torx screwdriver to tighten the security screw on the hood latch. Access the product rear panel Opening the cable manag

Strany 18 - Operations

Operations 22 WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power fr

Strany 19 - Operations 19

Operations 23 5. Install the PCIe riser cage. 6. Install the access panel (on page 20). 7. Install the server into the rack ("Installing the

Strany 20 - Install the access panel

Operations 24 CAUTION: Do not detach the cable that connects the battery pack to the cache module. Detaching the cable causes any unsaved data in

Strany 21 - Operations 21

Operations 25 5. Install the air baffle. 6. Install the access panel (on page 20). 7. Install the server into the rack ("Installing the serv

Strany 22

Setup 26 Setup Optional installation services Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and

Strany 23 - Remove the air baffle

Setup 27 • Leave a minimum clearance of 63.5 cm (25 in) in front of the rack. • Leave a minimum clearance of 76.2 cm (30 in) behind the rack. • L

Strany 24 - Install the air baffle

Setup 28 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of

Strany 25

Setup 29 WARNING: When installing a DC power supply, the ground wire must be connected before the positive or negative leads. WARNING: Remov

Strany 26 - Optimum environment

Contents 3 Contents Component identification ...

Strany 27 - Temperature requirements

Setup 30 WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack: • At least two people are needed to safely unl

Strany 28 - Power requirements

Setup 31 4. Install the power cord anchors. 5. Secure the cables to the cable management arm. IMPORTANT: When using cable management arm compo

Strany 29 - Rack warnings

Setup 32 Installing the operating system This ProLiant server ships with Intelligent Provisioning installed. Everything needed to manage and instal

Strany 30 - Installing hardware options

Setup 33 Registering the server To experience quicker service and more efficient support, register the product at the HP Product Registration websit

Strany 31 - Setup 31

Hardware options installation 34 Hardware options installation Introduction If more than one option is being installed, read the installation instru

Strany 32

Hardware options installation 35 7. Open the heatsink retaining bracket, and then remove the blank, if present. CAUTION: The pins on the proces

Strany 33 - Registering the server

Hardware options installation 36 9. Remove the clear processor socket cover. Retain the processor socket cover for future use. 10. Install the pro

Strany 34 - Processor option

Hardware options installation 37 CAUTION: Do not press down on the processor. Pressing down on the processor may cause damage to the processor s

Strany 35

Hardware options installation 38 14. Install the heatsink. 15. Install the air baffle (on page 24). 16. Install any full-length expansion boards,

Strany 36

Hardware options installation 39 • Single- and dual-rank PC3-10600 (DDR-1333) RDIMMs operating at up to 1333 MT/s at 1.35V • Single- and dual-rank

Strany 37

Contents 4 Hardware options installation ... 34

Strany 38 - Memory options

Hardware options installation 40 DIMM type DIMM rank 1 DIMM per channel 2 DIMMs per channel 3 DIMMs per channel LRDIMM Quad-rank (32 GB) 13334

Strany 39

Hardware options installation 41 Single-, dual-, and quad-rank DIMMs To understand and configure memory protection modes properly, an understanding

Strany 40 - HP SmartMemory

Hardware options installation 42 Item Description Definition 4 Voltage rating L = Low voltage (1.35V) U = Ultra low voltage (1.25V) Blank or omit

Strany 41 - DIMM identification

Hardware options installation 43 Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain memory erro

Strany 42 - Memory configurations

Hardware options installation 44 Online spare population For Online Spare memory mode configurations, observe the following guidelines: • Observe t

Strany 43

Hardware options installation 45 a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Extend the

Strany 44 - Installing a DIMM

Hardware options installation 46 CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers,

Strany 45 - Hot-plug hard drive options

Hardware options installation 47 2. Prepare the drive. 3. Install the drive. 4. Determine the status of the drive from the drive LED definitions

Strany 46

Hardware options installation 48 CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while

Strany 47 - Controller options

Hardware options installation 49 7. Install the cache module. 8. Connect the capacitor pack cable to the connector on the top of the cache module.

Strany 48

Contents 5 Option ROM Configuration for Arrays... 76 RO

Strany 49

Hardware options installation 50 To install the component: 1. Back up all data. 2. Close all applications. WARNING: To reduce the risk of pers

Strany 50

Hardware options installation 51 o Single capacitor pack holder o Double capacitor pack holder 10. Install the FBWC capacitor pack holder into t

Strany 51 - Double capacitor pack holder

Hardware options installation 52 o Single capacitor pack holder o Double capacitor pack holder 11. Install the access panel (on page 20). 12. I

Strany 52

Hardware options installation 53 Label color Output Green 1,200W CAUTION: To prevent improper cooling and thermal damage, do not operate th

Strany 53

Hardware options installation 54 FlexibleLOM option WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,

Strany 54 - FlexibleLOM option

Hardware options installation 55 To install the optional FlexibleLOM: 1. Firmly seat the FlexibleLOM in the slot, and then tighten the thumbscrew.

Strany 55 - Expansion board options

Hardware options installation 56 a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Extend the

Strany 56

Hardware options installation 57 7. Install the expansion board. 8. Connect any required internal or external cables to the expansion board. See t

Strany 57

Hardware options installation 58 5. Remove the PCIe riser cage. 6. Remove the expansion slot cover. 7. Install the expansion board. 8. Connect a

Strany 58

Hardware options installation 59 a. Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 3. Extend the

Strany 59

Component identification 6 Component identification Front panel components Item Description 1 Video connector 2 Serial pull tab 3 USB connecto

Strany 60 - 2U rack bezel option

Hardware options installation 60 7. Install an expansion board into the PCI riser cage. 8. Install the optional secondary PCI riser cage. 9. If

Strany 61

Hardware options installation 61 Install the 2U rack bezel into the chassis, and then lock the 2U rack bezel with the key. HP Trusted Platform Mod

Strany 62

Hardware options installation 62 • When using BitLocker, always retain the recovery key/password. The recovery key/password is required to enter Re

Strany 63

Hardware options installation 63 9. Install the TPM security rivet by pressing the rivet firmly into the system board. 10. Install the air baffle

Strany 64 - 7. Reboot the server

Hardware options installation 64 6. Press the Esc key to exit the current menu, or press the F10 key to exit RBSU. 7. Reboot the server. 8. Enable

Strany 65 - Cabling

Cabling 65 Cabling SAS drive cabling

Strany 66 - 150W PCIe power cable option

Cabling 66 FBWC cabling • SFF FBWC cabling • PCIe option Depending on the server configuration, you may need to remove the primary PCIe riser cag

Strany 67 - Cabling 67

Cabling 67 CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or in

Strany 68 - HP iLO Management

Software and configuration utilities 68 Software and configuration utilities Server mode The software and configuration utilities presented in this

Strany 69 - Active Health System

Software and configuration utilities 69 iLO enables and manages the Active Health System (on page 69) and also features Agentless Management. All ke

Strany 70 - Intelligent Provisioning

Component identification 7 Item Description Status 1 NIC status LED Solid green = Link to network Flashing green (1 Hz/cycle per sec) = Network

Strany 71 - Erase Utility

Software and configuration utilities 70 The data that is collected is managed according to the HP Data Privacy policy. For more information see the

Strany 72 - HP Insight Online

Software and configuration utilities 71 see the Resources tab on the HP website (http://www.hp.com/go/ilo). For consolidated drive and firmware upda

Strany 73 - HP Service Pack for ProLiant

Software and configuration utilities 72 HP Insight Remote Support software HP strongly recommends that you register your device for remote support t

Strany 74 - HP ROM-Based Setup Utility

Software and configuration utilities 73 • For more information about installing HP Insight Remote Support and enabling HP Insight Online, see the H

Strany 75 - Configuring AMP modes

Software and configuration utilities 74 HP ROM-Based Setup Utility RBSU is a configuration utility embedded in HP ProLiant servers that performs a w

Strany 76 - Utilities and features

Software and configuration utilities 75 Drives installed Drives used RAID level 1 1 RAID 0 2 2 RAID 1 3, 4, 5, or 6 3, 4, 5, or 6 RAID 5 M

Strany 77 - USB support

Software and configuration utilities 76 5. Press the Enter key to clear the warning. 6. Enter the serial number and press the Enter key. 7. Select

Strany 78 - Keeping the system current

Software and configuration utilities 77 For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup Utility

Strany 79 - ProLiant servers

Software and configuration utilities 78 Redundant ROM support The server enables you to upgrade or configure the ROM safely with redundant ROM suppo

Strany 80

Software and configuration utilities 79 Version control The VCRM and VCA are web-enabled Insight Management Agents tools that HP SIM uses to schedul

Strany 81 - Troubleshooting

Component identification 8 Item Description Status 2 NIC link/activity Off = No link to network. If the power is off, view the rear panel RJ-45 L

Strany 82 - Battery replacement

Software and configuration utilities 80 Change control and proactive notification HP offers Change Control and Proactive Notification to notify cust

Strany 83 - Battery replacement 83

Troubleshooting 81 Troubleshooting Troubleshooting resources The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedur

Strany 84 - Regulatory information

Battery replacement 82 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the bat

Strany 85 - Electrostatic discharge

Battery replacement 83 IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the batte

Strany 86 - Specifications

Regulatory information 84 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety

Strany 87

Electrostatic discharge 85 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strany 88 - Support and other resources

Specifications 86 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Ship

Strany 89

Specifications 87 Rated input current 9.1 A at 100 VAC 6.7 A at 200 VAC Maximum rated input power 897 W at 100V AC input 1321 W at 200V AC input Btu

Strany 90 - Customer Self Repair

Support and other resources 88 Support and other resources Before you contact HP Be sure to have the following information available before you call

Strany 91

Support and other resources 89 providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship

Strany 92 - Reparo feito pelo cliente

Component identification 9 Systems Insight Display LED and color Health LED System power LED Status that power supply is in standby. • Power suppl

Strany 93

Support and other resources 90 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'in

Strany 94

Support and other resources 91 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen,

Strany 95

Support and other resources 92 sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes

Strany 96 - Acronyms and abbreviations

Support and other resources 93 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel

Strany 97

Support and other resources 94

Strany 98

Support and other resources 95

Strany 99 - Documentation feedback

Acronyms and abbreviations 96 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Au

Strany 100 - Index 100

Acronyms and abbreviations 97 LFF large form factor NMI nonmaskable interrupt NVRAM nonvolatile memory ORCA Option ROM Configuration for Arrays

Strany 101 - Index 101

Acronyms and abbreviations 98 SIM Systems Insight Manager TMRA recommended ambient operating temperature TPM Trusted Platform Module UDIMM unregi

Strany 102 - Index 102

Documentation feedback 99 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat

Komentáře k této Příručce