HP SuperStack 3 Load Balancer Appliance Uživatelský manuál Strana 77

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 99
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 76
Important Safety Information 77
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 950. The conditions are only maintained if the
equipment to which it is connected also operates under SELV
conditions.
France and Peru only:
This unit cannot be powered from IT
supplies. If your supplies are of
IT type, this unit must be powered by 230V (2P+T) via an isolation
transformer ratio 1:1, with the secondary connection point labelled
Neutral, connected directly to earth (ground).
Impédance à la terre.
The switch should only be used in a rack if it is mounted on runners, a
shelf, or a tray to support the weight. The rack mount kits alone are
not sufficient to support the weight of the switch. The rack mount kits
must not be used to suspend the switch from under a table or desk, or
attach it to a wall.
If you are connecting the Server Load Balancer to a Type 3 Power
Module, read the Safety Information section in the Type 3 Power
Module User Guide.
WARNING: Fiber Optic ports - Optical Safety
Never look at the transmit laser while it is powered-up. Never look
directly at the fiber TX port and fiber cable ends when they are
powered-up.
Use of controls or adjustments of performance or procedures other
than those specified herein may result in hazardous laser emissions.
slb_gsg.bk Page 77 Thursday, May 31, 2001 8:57 AM
Zobrazit stránku 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 98 99

Komentáře k této Příručce

Žádné komentáře