268 Chapter 11
Managing SNAplus2 Clients
Managing Win32 Clients
The maximum size of the trace file. If two file names
are specified, tracing switches between the two files
when the current file reaches this size. If only one file
name is specified, this parameter is ignored; the file
size is not limited.
This parameter is optional. If it is not specified, the
default is 1000000 (bytes).
truncation_length
The Registry data type of this value is REG_DWORD.
The maximum length, in bytes, of the information
written to the trace file for each message. If a message
is longer than this, SNAplus2 writes only the start of
the message to the trace file, and discards the data
beyond truncation_length. This enables you to record
the most important information for each message but
avoid filling up the file with long messages.
This parameter is optional. If it is not specified,
SNAplus2 does not truncate messages (all the data
from each message is written to the file).
all_api
The Registry data type of this value is REG_SZ.
To trace messages for all APIs, set this parameter to
YES. In this case, SNAplus2 ignores the parameters
from appc through nof.
To disable tracing for all APIs, set all_api and all of the
parameters from appc through nof to NO.
To trace only messages for specific APIs, set all_api to
NO, and use the parameters from appc through nof to
indicate which APIs to trace.
This parameter is optional. If it is not specified, the
default is NO.
appc
The Registry data type of this value is REG_SZ.
To trace APPC API messages, set this parameter to
YES; otherwise, set it to NO.
This parameter is optional. If it is not specified, the
default is NO. If the all_api parameter is set to YES,
this parameter is ignored, and APPC messages are
traced.
cpic