Hp 600 Modular Disk System Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Úložný prostor Hp 600 Modular Disk System. HP 600 Modular Disk System User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 52
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP StorageWorks 600 Modular Disk System
User Guide
Abstract
This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, spe
cifications, and technical
support. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 495105-007
August 2011
Edition: 7
Zobrazit stránku 0
1 2 3 4 5 6 ... 51 52

Shrnutí obsahu

Strany 1 - User Guide

HP StorageWorks 600 Modular Disk System User Guide Abstract This guide describes identification, operations, setup, configuration and utilities, tro

Strany 2

Component identification 10 Device bay ID numbers SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (gree

Strany 3 - Contents

Component identification 11 SAS and SATA hard drive LED combinations Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On,

Strany 4 - Contents 4

Operations 12 Operations Important Safety Information Before installing this product, read the Important Safety Information document provided. F

Strany 5 - Component identification

Operations 13 To power up the MDS600: 1. Complete server hardware installation and cabling. See the server blade documentation. 2. Connect the SAS

Strany 6 - Front panel LEDs and button

Setup 14 Setup Space and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when

Strany 7 - Rear panel components

Setup 15 performs an emergency shutdown of the hard drive bays within a drawer if the temperature exceeds this limit for greater than 3 minutes. To

Strany 8 - Rear panel LEDs and buttons

Setup 16 Rack warnings WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extend

Strany 9

Setup 17 CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first, and c

Strany 10 - SAS and SATA hard drive LEDs

Setup 18 WARNING: The HP MDS600 Disk System is very heavy. To reduce the risk of personal injury or damage to the equipment: • Observe local occ

Strany 11 - Interpretation

Setup 19 • Hard drives are sensitive to excess vibration. Use care when opening and closing the drawer. • A RAID 1 mirror requires an even number

Strany 12 - Operations

© Copyright 2009, 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Strany 13 - Power down

Setup 20 CAUTION: To prevent improper cooling and thermal damage, do not operate the MDS600 for an extended period of time with the drawer open.

Strany 14 - Temperature requirements

Setup 21 6. Install the hard drive. WARNING: Pinch hazard—Keep hands out of front and rear of chassis when closing hard drive drawers. 7. Wh

Strany 15 - Power requirements

Setup 22 6. Push the I/O handle up. Be sure the I/O module is fully seated and the I/O module handle is in the locked position. CAUTION: For be

Strany 16 - Installing the enclosure

Setup 23 For a complete list of supported cables, see the QuickSpecs on the HP website (http://www.hp.com/go/mds600). Power cords The power cord sh

Strany 17

Configuration and utilities 24 Configuration and utilities Configuration tools Array Configuration Utility NOTE: ACU does not support mixing SA

Strany 18 - Hard drive overview

Configuration and utilities 25 Smart Components for ROM Flash To update the firmware on the server, controller, hard drives, or enclosure use Smart

Strany 19 - Installing the hard drives

Configuration and utilities 26 • From within Survey Utility • From within operating system-specific IML viewers o For NetWare: IML Viewer o For

Strany 20 - 5. Prepare the hard drive

Configuration and utilities 27 Keeping the system current Change control and proactive notification HP offers Change Control and Proactive Notificat

Strany 21 - Installing the I/O module

Troubleshooting 28 Troubleshooting When the MDS600 does not power up If the MDS600 does not power up: 1. Ensure that the MDS600 is connected to a w

Strany 22 - Cabling the MDS600

Troubleshooting 29 Issue Possible reasons Possible solutions I/O LED is amber • The I/O module might not be inserted properly, it might have a da

Strany 23 - Power cords

Contents 3 Contents Component identification ...

Strany 24 - Configuration and utilities

Troubleshooting 30 Status code Action 9 = Standby heartbeat failure Replace the I/O module that has an amber LED. If no I/O module has an amber LED

Strany 25 - Diagnostic tools

Troubleshooting 31 CAUTION: When fault tolerance is compromised, data loss can occur. However, it may be possible to recover the data. For more in

Strany 26 - Array Diagnostic Utility

Troubleshooting 32 • Do not remove a second drive from an array until the first failed or missing drive has been replaced and the rebuild process i

Strany 27 - Keeping the system current

Troubleshooting 33 Failure of another drive during rebuild If a non-correctable read error occurs on another physical drive in the array during the

Strany 28 - Troubleshooting

Regulatory compliance notices 34 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance

Strany 29

Regulatory compliance notices 35 • Hewlett-Packard Company P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-4

Strany 30 - Compromised fault tolerance

Regulatory compliance notices 36 • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 • 1281-514-3333 To identi

Strany 31

Regulatory compliance notices 37 For non-telecommunications products and for EU harmonized telecommunications products, such as Bluetooth® within po

Strany 32 - Time required for a rebuild

Regulatory compliance notices 38 Japanese notice BSMI notice Korean notice Class A equipment Class B equipment

Strany 33 - Troubleshooting 33

Regulatory compliance notices 39 Chinese notice Class A equipment Vietnam compliance marking notice This marking is for applicable products only.

Strany 34 - Class A equipment

Contents 4 Change control and proactive notification ... 27 C

Strany 35 - Class B equipment

Electrostatic discharge 40 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo

Strany 36 - Modifications

Specifications 41 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) M

Strany 37

Technical support 42 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Strany 38 - Korean notice

Technical support 43 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howev

Strany 39 - Ukraine notice

Technical support 44 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione

Strany 40 - Electrostatic discharge

Technical support 45 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte

Strany 41 - Specifications

Technical support 46 Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor

Strany 42 - Technical support

Technical support 47 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente.

Strany 45 - Technical support 45

Component identification 5 Component identification Front panel components Item Description 1 Drawer 1 2 Drawer 1 diagnostic cable access (For us

Strany 46 - Reparo feito pelo cliente

Acronyms and abbreviations 50 Acronyms and abbreviations ACU Array Configuration Utility ADG Advanced Data Guarding (also known as RAID 6) ADU Arr

Strany 47 - Technical support 47

Index 51 7 7-segment display 29 A ACU (Array Configuration Utility) 24 ADU (Array Diagnostic Utility) 26 airflow requirements 14 authorized

Strany 48 - Technical support 48

Index 52 J Japanese notice 38 K Korean notices 38 L LED behavior 28 LED, 7-segment display 8 LED, heartbeat 6, 8 LED, system fault 6, 8

Strany 49 - Technical support 49

Component identification 6 Front panel LEDs and button Item Description Status 1 Hard drive LEDs Normal mode (UID LED is solid) Green = The driv

Strany 50 - Acronyms and abbreviations

Component identification 7 Item Description Status 1 Hard drive LEDs Drive locate mode (UID LED is flashing) Green = The drive has been selected b

Strany 51 - Index 51

Component identification 8 Item Description 2 Power On/UID 2 status panel 3 Fan module 1 (Drawer 2) 4 Primary I/O module (Drawer 2) 5 SAS port 1 co

Strany 52 - Index 52

Component identification 9 Item Description Status 2 Internal Health LED Green = System health is good. Off = System is off. 3 GSI LED* Amber =

Komentáře k této Příručce

Žádné komentáře