Hp Hitachi Dynamic Link Manager Software Uživatelský manuál Strana 133

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 492
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 132
3. Creating an HDLM Environment
109
18. Modify the storage system settings.
Modify the storage system settings by following the procedure described in the
maintenance documentation for that particular storage system.
19. Restart each host.
20. Log on to Windows again as a member of the Administrators group.
21. Make sure that the program is running properly, by examining the results of the
dlnkmgr command's view operation.
Make sure that
on MSCS is displayed in Support Cluster. An example of
executing the
dlnkmgr command's view operation is as follows:
>dlnkmgr view -sys
HDLM Version : x.x.x-xx
Service Pack Version :
Load Balance : on(extended lio)
Support Cluster : on MSCS
Elog Level : 3
Elog File Size (KB) : 9900
Number Of Elog Files : 2
Trace Level : 0
Trace File Size(KB) : 1000
Number Of Trace Files : 4
Path Health Checking : on(30)
Auto Failback : on(1)
Remove LU : off
Intermittent Error Monitor : off
HDLM Manager Ver WakeupTime
Alive x.x.x-xx yyyy/mm/dd hh:mm:ss
HDLM Alert Driver Ver WakeupTime ElogMem Size
Alive x.x.x-xx yyyy/mm/dd hh:mm:ss 128
HDLM Driver Ver WakeupTime
Alive x.x.x-xx yyyy/mm/dd hh:mm:ss
License Type Expiration
Permanent -
KAPL01001-I The HDLM command completed normally. Operation
name = view, completion time = yyyy/mm/dd hh:mm:ss
22. Use the results of the view operation to check the version of the installed HDLM.
If
x.x.x-xx is displayed in HDLM Version, the correct version of HDLM has
been installed.
23. Use the results of the
view operation to check that the programs are running
properly.
Zobrazit stránku 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 491 492

Komentáře k této Příručce

Žádné komentáře