Hp MSA 2040 SAN Storage Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Úložný prostor Hp MSA 2040 SAN Storage. HP MSA 2040 SAN Storage User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP MSA
Storage Replication Adapter Software
User Guide
HP Part Number: 738384-001
Published: October 2013
Edition: 2
Abstract
The HP MSA Storage Replication Adapter (SRA) Software for VMware® vCenter Site Recovery Manager (SRM) enables
full-featured use of the VMware SRM with HP MSA 2040 and HP MSA P2000 G3 storage systems. Combining the HP MSA
storage system’s Remote Snap functionality with VMware SRM, the SRA provides an automated solution for implementing and
testing disaster recovery between geographically separated sites.
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - User Guide

HP MSA Storage Replication Adapter SoftwareUser GuideHP Part Number: 738384-001Published: October 2013 Edition: 2 AbstractThe HP MSA Storage Replicati

Strany 2

10 Installing and configuring the SRANOTE: Because the HP MSA SRA connects VMware SRM with MSA Remote Snap functionality, you might encounter differen

Strany 3 - Contents

: Installing SRM software 11Using SMU’s Replication Setup Wizard1. Use the Replication Setup Wizard in SMU to configure Remote Snap software, followin

Strany 4

12 Installing and configuring the SRA2. Run hp-msa-sra/setup.exe to install the SRA.The installation process is simple and straightforward. Once the S

Strany 5 - Figures 5

: Array and volume discovery 132 Using SRM for disaster recoveryOnce MSA Remote Snap software and VMware SRM software are configured and licensed at l

Strany 6 - 6Figures

14 Using SRM for disaster recoverymakes changes at both sites that require significant time and effort to reverse. Because of this, the privilege to t

Strany 7 - Tables 7

: Failover and failback 15ReprotectionAfter a recovery plan or planned migration is executed, there are often cases where the environment must continu

Strany 8

16 Using SRM for disaster recovery

Strany 9 - What’s new in this release

:173TroubleshootingVMware vCenter Server uses the SRA to present a detailed error message each time a recovery step fails.The SRA also creates a log f

Strany 10 - SRM requirements

18 Troubleshooting1022 Invalid or unknown ArrayId '{ArrayId}' in {cmd} request.Ensure that the array management controller system names and

Strany 11 - Installing the SRA

:19NOTE: You can expect to see certain errors in the log file when commands are executed to ensure that volumes are in a particular state if the volum

Strany 12 - Configuring SRM

© Copyright 2012-2013 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or c

Strany 14 - Failover and failback

:214 Best practice recommendationsSpecific recommendations for using HP MSA SRA 5.0 or later and Remote Snap software in conjunction with the VMware S

Strany 15 - Automated failback

22 Best practice recommendations

Strany 16

: Contacting HP 235 Support and other resourcesContacting HPFor worldwide technical support information, see the HP support website:http://www.hp.com/

Strany 17 - 3Troubleshooting

24 Support and other resources•HP MSA 2040 I/O Module Replacement Instructions•HP MSA Power and Cooling Module Replacement Instructions•HP MSA Bezel E

Strany 18

: Typographic conventions 25WARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that failure

Strany 19

26 Support and other resources

Strany 20 - 20 Troubleshooting

:276 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, su

Strany 21

28 Documentation feedback

Strany 22

Glossary 29Glossarychunk size The amount of contiguous data that is written to a vdisk member before moving to the next member of the vdisk.compatible

Strany 23 - 5 Support and other resources

HP MSA 2040 VDS and VSS Hardware Providers Installation Guide 31 Installing and configuring the SRA . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24 - Typographic conventions

30 Glossaryprimary site A primary site is a production environment that provides business-critical datacenter services. In a replication environment,

Strany 25

Glossary 31secondary volume The volume that is the destination for data in a replication set and that is not accessible to hosts. For disaster recover

Strany 26

32 Glossary

Strany 27 - 6 Documentation feedback

Index 33IndexAarray discovery 13automated failback 15automatic failover 14Ccreating a recovery plan 13Ddisaster recovery, using SRM for 13discovering

Strany 30 - 30 Glossary

Figures 5Figures1 Typical SRM configuration showing a protected site and recovery site ... 10

Strany 32 - 32 Glossary

Tables 7Tables1 SRA error messages and suggested actions ...171 Document conventions...

Strany 34 - 34 Index

: What’s new in this release 91 Installing and configuring the SRAThe HP MSA Storage Replication Adapter (SRA) for VMware® SRM enables full-featured u

Komentáře k této Příručce

Žádné komentáře