Hp P2000 G3 MSA Array Systems Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Úložný prostor Hp P2000 G3 MSA Array Systems. HP P2000 G3 MSA Array Systems User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 86
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
HP P2000 G3 iSCSI MSA System
User Guide
Part number: 614562-003
First edition: May 2011
Zobrazit stránku 0
1 2 3 4 5 6 ... 85 86

Shrnutí obsahu

Strany 1 - User Guide

HP P2000 G3 iSCSI MSA SystemUser GuidePart number: 614562-003First edition: May 2011

Strany 3 - Contents

HP P2000 G3 iSCSI MSA System User Guide 11About this guideThis guide provides information about hardware setup for the HP P2000 G3 10GbE iSCSI MSA Sys

Strany 4 - 4Contents

12 About this guideDocument conventions and symbolsWARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION:

Strany 5

HP P2000 G3 iSCSI MSA System User Guide 13Rack stabilityWARNING! To reduce the risk of personal injury or damage to equipment:• Extend leveling jacks

Strany 6 - 6Contents

14 About this guideHP websitesFor additional information, see the following HP websites:• http://www.hp.com • http://www.hp.com/go/storage• http://www

Strany 7

HP P2000 G3 iSCSI MSA System User Guide 151OverviewThe HP P2000 G3 10GbE iSCSI MSA System and HP P2000 G3 1Gb iSCSI MSA System are high-performance s

Strany 9

HP P2000 G3 iSCSI MSA System User Guide 172ComponentsFront panel componentsP2000 G3 (10GbE or 1Gb) iSCSI MSA LFFP2000 G3 (10GbE or 1Gb) iSCSI MSA SFF1

Strany 10 - 10 Tables

18 ComponentsDisk drive bay numbersP2000 G3 (10GbE or 1Gb) iSCSI MSA LFFP2000 G3 (10GbE or 1Gb) iSCSI MSA SFFRear panel views — controller modulesThe

Strany 11 - About this guide

HP P2000 G3 iSCSI MSA System User Guide 19Rear panel componentsP2000 G3 10GbE iSCSI MSAP2000 G3 1Gb iSCSI MSA1 AC Power supplies2 Controller module A3

Strany 12 - Monospace, italic font

Legal and notice information© Copyright 2011 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required f

Strany 13 - Product warranties

20 ComponentsIMPORTANT: See Connecting to the controller CLI port for information on enabling the controller enclosure’s USB Type B CLI port.Drive enc

Strany 14 - Documentation feedback

HP P2000 G3 iSCSI MSA System User Guide 21MSA2000 3Gb 3.5" 12-drive enclosureCacheTo enable faster data access from disk storage, the following t

Strany 15 - 1Overview

22 ComponentsCAUTION: To preserve the existing data stored in the CompactFlash, you must transport the CompactFlash from the failed controller to the

Strany 16 - 16 Overview

HP P2000 G3 iSCSI MSA System User Guide 233Installing the enclosuresInstallation checklistThe following table outlines the steps required to install t

Strany 17 - 2Components

24 Installing the enclosuresConnecting controller and drive enclosuresP2000 G3 MSA System controller enclosures — available in either 24-drive (2.5&qu

Strany 18 - Disk drive bay numbers

HP P2000 G3 iSCSI MSA System User Guide 25IMPORTANT: Adding a fourth drive enclosure may require a separate, longer cable. For a current list of suppo

Strany 19 - Rear panel components

26 Installing the enclosuresTable 3 SAS expansion cable requirements: controller module to expansion module connection1One 0.5m cable is required per

Strany 20 - MSA70 3Gb drive enclosure

HP P2000 G3 iSCSI MSA System User Guide 27Table 4 SAS expansion cable requirements: expansion module to expansion module connection1One 0.5m cable req

Strany 21 - Transportable CompactFlash

28 Installing the enclosuresNOTE: For clarity, the schematic illustrations of controller and expansion modules shown in this section provide only rele

Strany 22 - Super-capacitor pack

HP P2000 G3 iSCSI MSA System User Guide 29Figure 5 Cabling connections between P2000 G3 controllers and an MSA70 3Gb drive enclosureThe diagram above

Strany 23 - 3Installing the enclosures

HP P2000 G3 iSCSI MSA System User Guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24 - 24 Installing the enclosures

30 Installing the enclosuresFigure 7 Cabling connections between P2000 G3 controllers and D2700 6Gb drive enclosuresThe figure above provides sample d

Strany 25 - P2000 G3 Controller Enclosure

HP P2000 G3 iSCSI MSA System User Guide 31Figure 8 Fault-tolerant cabling: P2000 G3 controllers and MSA2000 3Gb drive enclosuresFigure 9 Fault-toleran

Strany 26

32 Installing the enclosuresFigure 10 Cabling connections between dual controllers and drive enclosures of mixed typeThe figure above shows a sample f

Strany 27

HP P2000 G3 iSCSI MSA System User Guide 33Testing enclosure connectionsNOTE: Once the enclosures’ power-on sequence succeeds, the storage system is re

Strany 28

34 Installing the enclosures2. Plug the power cord into the power cord connector on the back of the drive enclosure (see Figure 11). Plug the other en

Strany 29

HP P2000 G3 iSCSI MSA System User Guide 35DC modelLocate the two DC power cables provided with your controller enclosure.Figure 13 DC Power cable feat

Strany 30

36 Installing the enclosures

Strany 31

HP P2000 G3 iSCSI MSA System User Guide 374 Connecting hostsHost system requirementsData hosts connected to P2000 G3 MSA System arrays must meet the f

Strany 32

38 Connecting hosts1Gb iSCSI host portsP2000 G3 1Gb iSCSI MSA controllers use the Internet SCSI interface protocol for host port connection, featuring

Strany 33 - Powering on/powering off

HP P2000 G3 iSCSI MSA System User Guide 39Dual controller configurationsOne server/one HBA/dual pathTwo servers/one HBA per server/dual pathFour serve

Strany 34 - Power Cords

4Contents4 Connecting hosts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Host system requir

Strany 35 - Power cycle

40 Connecting hostsConnecting switch attach configurationsDual controller configurationTwo servers/two switchesFour servers/SAN fabric6Gb/s6Gb/sServer

Strany 36 - 36 Installing the enclosures

HP P2000 G3 iSCSI MSA System User Guide 41Connecting remote management hostsThe management host directly manages systems out-of-band over an Ethernet

Strany 37 - 4 Connecting hosts

42 Connecting hostsIMPORTANT: Remote Snap must be licensed on all systems configured for replication, and the controller module firmware version must

Strany 38 - 10GbE iSCSI host ports

HP P2000 G3 iSCSI MSA System User Guide 43Multiple servers/different networks/multiple switchesThe diagram below shows 10GbE iSCSI host interface conn

Strany 39 - One server/one HBA/dual path

44 Connecting hostsMultiple servers/single network/single switchThe diagram below shows 10GbE iSCSI connection and 10GbE iSCSI-based replication, with

Strany 40 - Dual controller configuration

HP P2000 G3 iSCSI MSA System User Guide 45With either of the replication configurations shown in the two previous figures, Virtual Local Area Network

Strany 41

46 Connecting hosts

Strany 42

HP P2000 G3 iSCSI MSA System User Guide 475 Connecting to the controller CLI portDevice descriptionP2000 G3 MSA System controllers feature a new comma

Strany 43

48 Connecting to the controller CLI port2. Insert the P2000 G3 Software Support/Documentation CD into the CD drive on a Linux or Windows computer on t

Strany 44

HP P2000 G3 iSCSI MSA System User Guide 49Figure 20 Connecting a USB cable to the CLI port3. Enable the CLI port for subsequent communication:• Linux

Strany 45 - Updating firmware

HP P2000 G3 iSCSI MSA System User Guide 5If the controller has failed or does not start, is the Cache Status LED on/blinking? . . . . . . . . . . . .

Strany 46 - 46 Connecting hosts

50 Connecting to the controller CLI port7. At the prompt, type the following command to set the values you obtained in Step 1 for each network port, f

Strany 47 - Obtaining IP values

HP P2000 G3 iSCSI MSA System User Guide 516 Basic operationVerify that you have completed the sequential “Installation Checklist” instructions in Tabl

Strany 48

52 Basic operation

Strany 49 - Connect USB cable to CLI

HP P2000 G3 iSCSI MSA System User Guide 537TroubleshootingCLI port connectionP2000 G3 MSA System controllers feature a new CLI port employing a mini-U

Strany 50 - IP-address

54 TroubleshootingIf the enclosure does not initializeIt may take up to two minutes for the enclosures to initialize. If the enclosure does not initia

Strany 51 - 6 Basic operation

HP P2000 G3 iSCSI MSA System User Guide 55Is the controller back panel OK LED off?Is the controller back panel Fault/Service Required LED amber?Are bo

Strany 52 - 52 Basic operation

56 TroubleshootingIs a connected host port’s Host Link Status LED off?Is a connected port’s Expansion Port Status LED off?Is a connected port’s Networ

Strany 53 - 7Troubleshooting

HP P2000 G3 iSCSI MSA System User Guide 57Is the power supply’s Input Power Source LED off? Is the power supply’s Voltage/Fan Fault/Service Required L

Strany 54 - Diagnostic steps

58 TroubleshootingIf the controller has failed or does not start, is the Cache Status LED on/blinking?Transporting CacheTo preserve the existing data

Strany 55

HP P2000 G3 iSCSI MSA System User Guide 595. Move the SFP+ to a port with a known good link status.This step isolates the problem to the external data

Strany 57

60 Troubleshooting6. Verify that the HBA is fully seated, and that the PCI slot is powered on and operational.7. Replace the HBA with a known good HBA

Strany 58 - Transporting Cache

HP P2000 G3 iSCSI MSA System User Guide 61Isolating Remote Snap replication faultsCabling for replicationRemote Snap replication is a disaster-recover

Strany 59

62 TroubleshootingCan you view information about remote links?Can you create a replication set?No Proper firmware revision supporting Remote Snap is n

Strany 60 - 60 Troubleshooting

HP P2000 G3 iSCSI MSA System User Guide 63Can you replicate a volume?No Unable to select the replication mode?• In SMU, review event logs for indicato

Strany 61 - Cabling for replication

64 TroubleshootingCan you view a replication image?Can you view remote systems?Resolving voltage and temperature warnings1. Check that all of the fans

Strany 62 - 62 Troubleshooting

HP P2000 G3 iSCSI MSA System User Guide 65Sensor locationsThe storage system monitors conditions at different points within each enclosure to alert yo

Strany 63 - Can you replicate a volume?

66 TroubleshootingWhen a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log.Power suppl

Strany 64 - Can you view remote systems?

HP P2000 G3 iSCSI MSA System User Guide 67A LED descriptionsFront panel LEDsTable 12 LEDs — HP P2000 G3 MSA Systems controller enclosure front panelsL

Strany 65 - Temperature sensors

68 LED descriptionsDisk drive LEDsTable 13 LEDs — Disk drive LEDsLED Description1 Fault/UID (amber/blue)2Online/Activity (green)Table 14 LEDs — Disk d

Strany 66

HP P2000 G3 iSCSI MSA System User Guide 691This Fault/UID state can indicate that the disk is a leftover. The fault may involve metadata on the disk r

Strany 67 - A LED descriptions

HP P2000 G3 iSCSI MSA System User Guide 7Figures1 P2000 G3 MSA System component connection combinations. . . . . . . . . . . . . . . . . . . . . . .

Strany 68 - Disk drive LEDs

70 LED descriptionsIMPORTANT: Early versions of the P2000 G3 MSA System controller modules show network port LED labels in reversed position: LINK is

Strany 69 - Rear panel LEDs

HP P2000 G3 iSCSI MSA System User Guide 71P2000 G3 1Gb iSCSI MSANOTE: Once a Link Status LED is lit, it remains so, even if the controller is shutdown

Strany 70 - LED Description Definition

72 LED descriptionsD2700 6Gb drive enclosureP2000 G3 MSA System controllers support D2700 6Gb drive enclosures. For information about P2000G3MSA Syste

Strany 71 - P2000 G3 1Gb iSCSI MSA

HP P2000 G3 iSCSI MSA System User Guide 73MSA2000 3Gb 3.5" 12-drive enclosurePower supply LEDsPower redundancy is achieved through two independen

Strany 72

74 LED descriptionsNOTE: See Powering on/powering off on page 33 for information on power-cycling enclosures.AC model DC modelTable 19 LEDs — HP P2000

Strany 73 - Power supply LEDs

HP P2000 G3 iSCSI MSA System User Guide 75B Environmental requirements and specificationsSafety requirementsInstall the system in accordance with the

Strany 74

76 Environmental requirements and specificationsWeight and placement guidelinesRefer to Physical requirements on page 77 for detailed size and weight

Strany 75 - Safety requirements

HP P2000 G3 iSCSI MSA System User Guide 77NOTE: Connections to this device must be made with shielded cables — grounded at both ends – with metallic R

Strany 76 - Management host requirements

78 Environmental requirements and specifications1Weights shown are nominal, and subject to variances.2Weights may vary due to different power supplies

Strany 77 - Physical requirements

HP P2000 G3 iSCSI MSA System User Guide 79Power cord requirementsEach enclosure equipped with AC power supply modules requires two AC power cords that

Strany 79 - Power cord requirements

80 Environmental requirements and specifications

Strany 80

HP P2000 G3 iSCSI MSA System User Guide 81C Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of the p

Strany 81 - C Electrostatic discharge

82 Electrostatic discharge

Strany 82 - 82 Electrostatic discharge

HP P2000 G3 iSCSI MSA System User Guide 83IndexNumerics2U12large form factor (LFF) enclosure 772U24small form factor (SFF) enclosure 77AaccessingCLI (

Strany 83

84 IndexIDs, correcting 54initial configuration 47input frequency requirement 78input voltage requirement 78installation checklist 23site requirements

Strany 84 - 84 Index

HP P2000 G3 iSCSI MSA System User Guide 85power cyclepower off 34, 35power on 33, 35power supplyAC power requirements 75DC power requirements 75site w

Strany 85

86 Index

Strany 86 - 86 Index

HP P2000 G3 iSCSI MSA System User Guide 9Tables1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Komentáře k této Příručce

Žádné komentáře