Object Alert text
Description
Possibl e cause Solution
Transition
state:
Reconguring
The logical disk is
being recongured.
Conguration
changes are
being made to the
logical disk by an
application other
than ASM.
No action is required.
Status: Not
ready
Logical disk not
usable while an
operation is being
performed.
Operation is
being
performed that
prevents logical disk
from being u
sed.
No action is r
equired.
Status: O fine
Logical disk is not
usable.
Administrator has
taken logical disk
ofine.
Return the logical disk to
online.
Status: Failed
Logical disk is not
usable.
Hardware failure has
occurred.
See array controller
documentation for more
information.
Recover
ing from logical disk failure
Applica
tion component or s hared folder data stored on a logical disk that failed is lost. To recover
the data
and reallocate storage on your HP All-in-One Storage System, replace any failed hard
drives, allocate new storage on your HP All-in-One Storage System using a storage-allocation wizard
to replace the lost storage, and then restore the data to the new allocated storage using a backup
(see Restoring data from backups on page 40).
NOTE:
Snapsh
ots cannot be used to recover data lost as a result of logical disk failure. Snapshots of Exchange
storag
e groups, SQL Server databases, user-dened applications, and shared folders are stored on the
same l
ogical disks as the original data, and therefore are also lost.
All-in-One Storage Manager