HP Scalable File Share User Guide
G3.2-0
HP Part Number: SFSUGG32-D
Published: October 2009
Edition: 4
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - Edition: 4

HP Scalable File Share User GuideG3.2-0HP Part Number: SFSUGG32-DPublished: October 2009Edition: 4

Strany 2

\ Indicates the continuation of a code example.| Separates items in a list of choices.WARNING A warning calls attention to important information that

Strany 3 - Table of Contents

HP StorageWorks Scalable File Share Release Notes Version 2.3For documentation of previous versions of HP SFS, see:• HP StorageWorks Scalable File Sha

Strany 5 - Table of Contents 5

1 What's In This Version1.1 About This ProductHP SFS G3.2-0 uses the Lustre File System on MSA hardware to provide a storage system forstandalone

Strany 6 - List of Figures

1 CentOS 5.3 is available for download from the HP Software Depot at:http://www.hp.com/go/softwaredepot1.3.1 Hardware ConfigurationA typical HP SFS sy

Strany 7 - List of Tables

Figure 1-1 Platform Overview1.3 Supported Configurations 15

Strany 8

Figure 1-2 Server PairsFigure 1-2 shows typical wiring for server pairs.1.3.1.1 Server Memory RequirementsThe Lustre Operations Manual section 3.1.6 d

Strany 9 - About This Document

IMPORTANT: Memory requirements for HP SFS G3.2-0 have increased from previous versions.Before deciding whether to upgrade to HP SFS G3.2-0, please det

Strany 10 - Related Information

• DL380 G6 server support (required for IB QDR)• The -c option to the gen_hb_config_files.pl script automatically copies the Heartbeatconfiguration fi

Strany 11 - HP Encourages Your Comments

2 Installing and Configuring MSA ArraysThis chapter summarizes the installation and configuration steps for MSA2000fc arrays use inHP SFS G3.2-0 syste

Strany 12

© Copyright 2009 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Strany 13 - 1 What's In This Version

IMPORTANT: The size of a Lustre MDT or OST is limited to 8 TB. Therefore, any volume createdon the MSA2000 must be less than or equal to 8796 GB. If a

Strany 14 - 1.3.1 Hardware Configuration

# forallmsas show disks ; doneThe CLI syntax for specifying disks in enclosures differs based on the controller type usedin the array. The following v

Strany 15 - Figure 1-1 Platform Overview

correct assignment of multipath priorities. HP recommends mapping all ports to each volumeto facilitate proper hardware failover.a. Create vdisks in t

Strany 16

1. Enable FTP on the MSA with the CLI command:# set protocols ftp enable2. Use FTP from a Linux host to upload log files:# ftp MSAIPaddress3. Log in w

Strany 17 - 1.5 Release Notes

2. If you are running with a firewall, the sendmail firewall port 25 must be open by addingthe following line to /etc/sysconfig/iptables before the fi

Strany 18 - 1.5.3 Known Issues

3 Installing and Configuring HP SFS Software on ServerNodesThis chapter provides information about installing and configuring HP SFS G3.2-0 software o

Strany 19 - 2.2 Accessing the MSA CLI

3.1 Supported FirmwareFollow the instructions in the documentation which was included with each hardware componentto ensure that you are running the l

Strany 20 - 2.3.2 Creating New Volumes

3.2 Installation RequirementsA set of HP SFS G3.2-0 file system server nodes should be installed and connected by HP inaccordance with the HP SFS G3.2

Strany 21

The following optional, but recommended, line sets up an Ethernet network interface. More thanone Ethernet interface may be set up using additional ne

Strany 22 - 2.4 MSA2000 Monitoring

During the Kickstart post-installation phase, you are prompted to install the HP SFS G3.2-0 DVDinto the DVD drive:Please insert the HP SFS G3.2-0 DVD

Strany 23 - 2.4.1 email Notifications

Table of ContentsAbout This Document...9Intended

Strany 24 - 2.4.2 SNMP Monitoring

NOTE: USB drives are not scanned before the installer reads the Kickstart file, so you areprompted with a message indicating that the Kickstart file c

Strany 25

NOTE: The output from Installation Phase 1 is contained in /var/log/postinstall.log.Proceed to “Installation Phase 2”.3.4 Installation Phase 2After th

Strany 26 - 3.1 Supported Firmware

IMPORTANT: This step must be performed for 10 GigE systems only. Do not use this processon InfiniBand systems.If your system uses Mellanox ConnectX HC

Strany 27 - 3.2 Installation Requirements

3.5.2 Creating the /etc/hosts fileCreate an /etc/hosts file with the names and IP addresses of all the Ethernet interfaces oneach system in the file s

Strany 28 - 3.3 Installation Phase 1

enabling direct user login access to the file system server nodes. In particular, the shadowpassword information should not be provided through NIS or

Strany 29 - 3.3 Installation Phase 1 29

This import command should be performed by root on each system that installs signed RPMpackages.3.6 Upgrade InstallationIn some situations you may upg

Strany 30

1. For the first member of the failover pair, stop the Heartbeat service to migrate the Lustrefile system components from this node to its failover pa

Strany 31 - 3.4 Installation Phase 2

6. For the upgrade from SFS G3.0-0 to G3.1-0 or SFS G3.2-0, you must re-create the Heartbeatconfiguration files to account for licensing. For the deta

Strany 33 - 3.5.4 Configuring ntp

4 Installing and Configuring HP SFS Software on ClientNodesThis chapter provides information about installing and configuring HP SFS G3.2-0 software o

Strany 34

3.5.1 Configuring Ethernet and InfiniBand or 10 GigE Interfaces...323.5.2 Creating the /etc/hosts file.

Strany 35 - 3.6 Upgrade Installation

If the client is using the HP recommended 10 GigE ConnectX cards from Mellanox, the ConnectXEN drivers must be installed. These drivers can be downloa

Strany 36 - # end lustre config

NOTE: The network addresses shown above are the InfiniBand IPoIB ib0 interfaces for theHP SFS G3.2-0 Management Server (MGS) node, and the MGS failove

Strany 37 - 3.6.2 Client Upgrades

5. When successfully completed, the newly built RPMs are available in /usr/src/redhat/RPMS/x86_64. Proceed to “Installation Instructions” (page 40).4.

Strany 38

5 Using HP SFS SoftwareThis chapter provides information about creating, configuring, and using the file system.5.1 Creating a Lustre File SystemThe f

Strany 39 - 4.1 Installation Requirements

To see the multipath configuration, use the following command. Output will be similar to theexample shown below:# multipath -llmpath7 (3600c0ff000d547

Strany 40 - 4.2 Installation Instructions

node3,options lnet networks=o2ib0,/dev/mapper/mpath6,/mnt/ost4,ost,testfs,icnode1@o2ib0:icnode2@o2ib0 ,,,,"_netdev,noauto",icnode4@o2ib0

Strany 41

2. Start the file system manually and test for proper operation before configuring Heartbeatto start the file system. Mount the file system components

Strany 42

3. Heartbeat uses one or more of the network interfaces to send Heartbeat messages using IPmulticast. Each failover pair of nodes must have IP multica

Strany 43 - 5 Using HP SFS Software

You can generate the simple files ha.cf, haresources, and authkeys by hand if necessary.One set of ha.cf with haresources is needed for each failover

Strany 44 - 44 Using HP SFS Software

The haresources2cib.py script is executed by gen_hb_config_files.pl.5.2.3.2 Editing cib.xmlThe haresources2cib.py script places a number of default va

Strany 45 - 5.1.1.1 Multiple File Systems

7 Known Issues and Workarounds...617.1 Server Reboot...

Strany 46 - 5.2 Configuring Heartbeat

• The .sig and .last files should be removed from /var/lib/heartbeat/crm when anew cib.xml is copied there. Otherwise, Heartbeat ignores the new cib.x

Strany 47 - 5.2.3 Configuration Files

NOTE: Changing the authentication string in /etc/ha.d/authkeys causes Heartbeat toreport numerous warnings instead of error messages.atlas1 heartbeat:

Strany 48 - 48 Using HP SFS Software

This forces you to manually start the Heartbeat service and the file system after a file systemserver node is rebooted.5.5 Monitoring Failover PairsUs

Strany 49 - 5.2.5 Things to Double-Check

5.7.1 Examining and TroubleshootingIf your file system is not operating properly, you can refer to information in the Lustre 1.8Operations Manual, PAR

Strany 50 - 5.2.6 Things to Note

This displays INACTIVE if no recovery is in progress. If any recovery is in progress or complete,the following information appears:status: RECOVERING

Strany 51 - 5.4 Stopping the File System

The problem is in line #08. The MDT is related to 10.129.10.1@o2ib, but in this example theIP address is for the MGS node not the MDT node. So MDT wil

Strany 52 - 5.5 Monitoring Failover Pairs

After a few minutes, the MGS mount is active with df.16. Boot the MDS node.17. Start the Heartbeat service on the MDS node:# service heartbeat startAf

Strany 53 - 5.7.1.1 On the Server

common system performance data such as CPU, disk, and network traffic, it also supportsreporting of both Lustre and InfiniBand statistics. Read/write

Strany 55

6 LicensingA valid license is required for normal operation of HP SFS G3.2-0. HP SFS G3.2-0 systems arepreconfigured with the correct license file at

Strany 56 - 5.7.1.3 On the Client

List of Figures1-1 Platform Overview...

Strany 57

[root@atlas1] grep "SFS License" /var/log/messagesFeb 9 17:04:08 atlas1 SfsLicenseAgent: Error: No SFS License file found. Check /var/flexlm

Strany 58

7 Known Issues and WorkaroundsThe following items are known issues and workarounds.7.1 Server RebootAfter the server reboots, it checks the file syste

Strany 59 - 6 Licensing

NOTE: Use the appropriate device in place of /dev/mapper/mpath?b. For example, if the --dryrun command returned:Parameters: mgsnode=172.31.80.1@o2ib m

Strany 60 - 60 Licensing

A HP SFS G3 PerformanceA.1 Benchmark PlatformHP SFS G3, based on Lustre File System Software, is designed to provide the performance andscalability ne

Strany 61 - 7.4 MDS Is Unresponsive

Figure A-2 shows more detail about the storage configuration. The storage comprised a numberof HP MSA2212fc arrays. Each array had a redundant pair of

Strany 62 - 7.8 SELinux Support

Figure A-3 Single Stream ThroughputFor a file written on a single OST (a single RAID volume), throughput is in the neighborhood of200 MB/s. As the str

Strany 63 - A HP SFS G3 Performance

filled with the new data. At the point (14:10:14 in the graph) where the amount of data reachedthe cache limit imposed by Lustre (12 GB), throughput d

Strany 64 - A.2 Single Client Performance

Figure A-6 Multi-Client Throughput ScalingIn general, Lustre scales quite well with additional OSS servers if the workload is evenlydistributed over t

Strany 65

A.4 One Shared FileFrequently in HPC clusters, a number of clients share one file either for read or for write. Forexample, each of N clients could wr

Strany 66 - A.3 Throughput Scaling

Another way to measure throughput is to only average over the time while all the clients areactive. This is represented by the taller, narrower box in

Strany 67 - A.3 Throughput Scaling 67

List of Tables1-1 Supported Configurations ...

Strany 68 - A.4 One Shared File

For workloads that require a lot of disk head movement relative to the amount of data moved,SAS disk drives provide a significant performance benefit.

Strany 69 - A.6 Random Reads

Each disk shelf in the platform used for deep shelf testing was configured in the same manneras described in “Benchmark Platform” (page 63). The arran

Strany 70 - A.7.1 Benchmark Platform

Figure A-12 Client Count Versus Total Throughput (MB/s)A.7.3 Throughput ScalingA single file accessed by eight clients benefits from increased stripin

Strany 71

The OSTs were populated with 146 GB SAS drives. Stripe placement was controlled by defaultoperation of the HP SFS file system software. Specific contr

Strany 72 - A.8 10 GigE Performance

network buffering parameters were set as described in the documentation for the configurednetwork controller.A.8.2 Single Stream ThroughputThroughput

Strany 73 - A.8.1 Benchmark Platform

Figure A-16 Client Count Versus Total Throughput (MB/s)A.8.3 Throughput ScalingAs in “Throughput Scaling” (page 66), a set of 16 clients wrote or read

Strany 75 - A.8.3 Throughput Scaling

IndexSymbols/etc/hosts fileconfiguring, 3310 GigEclients, 39configuring, 32installation, 31performance, 72Bbenchmark platform, 63Ccache limit, 66cib.x

Strany 76

release notes, 17rolling upgrades, 35Sscaling, 66server security policy, 17shared files, 68stonewalling, 68stonith, 46support, 10Tthroughput scaling,