Command Line Interface Commands 61
Table 4-36 hostModeOption Parameter Values and Description
hostModeOption Values Description
2 Specify this value when using VERITAS™ Database Edition/Advanced Cluster for Real
Application Clusters or VERITAS™ Cluster Server 4.0 (I/O fencing feature).
6 Specify this value when all of the following conditions are satisfied:
• The host connection mode is set to Windows (mode 0C) or Windows Extension (mode 2C).
• An Emulex
®
host bus adapter is in use.
• A mini-port driver is in use.
• The TPRLO parameter for the mini-port driver of the host bus adapter is set to 2.
7 Specify this value when all of the following conditions are satisfied:
• The host connection mode is set to Standard (mode 00) or Solaris (mode 09).
• You want to let the system automatically recognize the reduction and increase in the number
of devices while a SUN™ host bus adapter is in use.
12 Specify this value when all of the following conditions are satisfied:
• The host connection mode is set to HP-UX (mode 03).
• You want to prevent devices to which no paths have been defined from creating a device file
when the HP-UX host is connected.
13 Specify this value when you want to get a SIM notification when the number of unsuccessful
connections between ports exceeds a threshold.
14 Specify this value when all of the following conditions are satisfied:
• The host connection mode is set to Tru64 (mode 07).
• You want to use TruCluster to set up a cluster on both a Continuous Access XP primary and
a secondary volume.
Command execution example: In this example, the CLI command modifies the settings for a port (port number:
16) of a storage subsystem (serial number: 10001, model: XP1024) as follows. The command:
• changes the value for the hostmode parameter to Standard, for the port's host storage domain (domain
ID: 0)
• changes the topology to Fabric(off), FC-AL
• sets the Fibre Channel address to 73
• disables LUN security by specifying false
• sets the transmission speed of the Fibre Channel to 1
hdvmcli ModifyPort -o "D:\logs\XP1024 ModifyPort.log" serialnum=10001 model=XP1024
port=16 domain=0 hostmode=Standard "topology=Fabric(off), FC-AL" fibreaddr=73
lunsec=false channelspeed=1
Command execution result:
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Port elements:
An instance of Port
objectID=PORT.HDS9980V.10001.16
portID=16
portType=Fibre
fibreAddress=73
topology=Fabric(off), FC-AL
displayName=CL2-A
lunSecurityEnabled=false
controllerID=5
worldWidePortName=50.06.0E.80.03.3A.99.10
channelSpeed=1
slprNumber=-1
portRole=Target
List of 1 HostStorageDomain elements:
An instance of HostStorageDomain
Komentáře k této Příručce