Command line interface commands
209
Table 4-96 AddConfigFileForReplication command parameters
Parameter Name Status Description
pvolhostid
Required Host ID for identifying the P-VOL
When using Method 1, specify the host ID of the P-VOL in a group
specified in the definition file.
pvolinstancenum
Optional Instance number of the HORCM instance for managing the P-VOL
When using Method 1, specify the instance number of the P-VOL of a
group specified in the definition file.
NOTE: You must specify this parameter when you are using method 1 or
2.
pvolportnum
Optional Port number of the HORCM instance for managing the P-VOL
Specify an integer in the following range:
• Solaris:0 to 65535.
• AIX, Windows, HP-UX, and Linux 1 to 65535.
This parameter is invalid when the pvolinstancenum is specified.
NOTE: You must specify this parameter when you are using method 3.
svolhostid
Required Host ID for identifying the S-VOL
When using Method 1, specify the host ID of the S-VOL of a group
specified in the definition file.
svolinstancenum
Optional Instance number of the HORCM instance for managing the S-VOL
When using Method 1, specify the instance number of the S-VOL of a
group specified in the definition file.
NOTE: You must specify this parameter when you are using method 1 or
2.
svolportnum
Optional Port number of the HORCM instance for managing the S S-VOL
Specify an integer in the following range:
• Solaris:0 to 65535.
• AIX, Windows, HP-UX, and Linux 1 to 65535.
This parameter is invalid when the svolinstancenum is specified.
NOTE: You must specify this parameter when you are using method 3.
pvolarraytype
Required Model of the storage subsystem that includes the P-VOL
pvolserialnum
Required Serial number of the storage subsystem that includes the P-VOL
pvoldevnum
Required Device number of the P-VOL
This parameter can be specified in decimal, and in colon-separated
hexadecimal. If you specify a hexadecimal number, for
XP12000/XP10000/SVS200, XP1024/XP128, and XP512/XP48, use the
xx:yy format, where xx is the CU number, and yy is the LDEV number.
For XP24000/XP20000, use the ww:xx:yy format, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number. ww is
optional. If you omit ww, the LDKC number is regarded as 0.
NOTE: The execution results are output in decimal.
pvolportid
Optional Port number in the HORCM configuration file that manages the P-VOL
path
NOTE: If you specify this parameter, specify either pvolportid or
pvolportname. Do not specify both parameters at the same time. This
might cause an error to occur.