Hp XP Continuous Access Software Uživatelský manuál Strana 172

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 412
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 171
172 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
M=W (Valid for PSUS state only) In the P-VOL case, this
designates “suspended” with S-VOL R/W enabled.
In the S-VOL case, this designates that the S-VOL can
accept writes.
M=N (Valid for COPY/RCPY/PAIR/PSUE state) A listed
volume means that reading is disabled.
Example This example shows a pairresync on group VG01. pairdisplay shows two
volumes in the COPY state. The
copy% value indicates how much of the
P-VOL is in sync with the S-VOL.
# pairresync –g VG01
# pairdisplay -g VG01 –fc -l
Group PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status,Copy%,P-LDEV# M
VG01 d1(L) (CL2-P , 0, 0-0)35641 58..P-VOL COPY, 89 61 -
VG01 d2(L) (CL2-P , 0, 1-0)35641 59..P-VOL COPY, 96 62 -
Error Codes The table lists specific error codes for the pairresync command.
Category Error Code Error Message Value
Volume status
unrecoverable
EX_ENQVOL Unmatched volume status within the group 236
EX_INCSTG Inconsistent status in group 229
EX_INVVOL Invalid volume status 222
EX_INVSTP Invalid pair status 228
Zobrazit stránku 171