About Cross-OS File Exchange Operations 2-35
Hitachi USP V Cross-OS File Exchange User’s Guide
– If other values outside the range are given, the default value applies.
• Retry Wait Time Function:You can set the wait time interval by specifying
the environment variable(FAL_RETRY_WAIT_TIME). FX attempts to send data
during reserved status.
– The default is 1 second, where no definition of the environment variable
is given.
– The range of the FAL_RETRY_WAIT_TIME variable is 1-60 seconds.
– If other values outside the range are given, the default value applies.
• Retry target function: You can set system error codes, which are retry
triggers, by specifying the environment variable (FAL_RETRY_TARGET).
– You can set up to 5 system error codes separated by commas. If you set
six or more system error codes, FX will ignore all after the fifth.
– If no environment variable definition is given, an error code 16(EBUSY)
will appear.
– You can set up to 5 system error codes, separated by commas.
– If other values outside the range are given, the 16(EBUSY) error code
applies.
– For setting error codes outside default values, please contact your Hitachi
Data Systems technical representative.