Strany 1 - HP-UX 11i v2

HyperFabric Administrator’s GuideHP-UX 11i v2Edition 14Manufacturing Part Number : B6257-90043March 2004United States© Copyright 2004 Hewlett-Packard

Strany 3 - Contents

Configuring HyperFabricConfiguring the HyperFabric EMS MonitorChapter 48612. Validate by pressing OKNOTE Although EMS is able to monitor each HyperFabri

Strany 4

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 4 87Configuring HyperFabric with ServiceGuardHyperFabric supports the ServiceGuar

Strany 5

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 488Figure 4-2 below shows a HyperFabric switch configuration withServiceGuard. Th

Strany 6

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 4 89Figure 4-2 An ServiceGuard Configuration (with Two HyperFabricSwitches)HFadap

Strany 7

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 490How HyperFabric Handles Adapter FailuresHyperFabric adapters are handled diff

Strany 8

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 4 91Example 1:This example, illustrated by Figure 4-3 below, presents an HAconfig

Strany 9

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 492Example 2:This example, illustrated by Figure 4-4 below, shows the same node

Strany 10

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 4 93Example 3:This final example, illustrated by Figure 4-5 below, shows a situat

Strany 11 - About This Document

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 494Configuring HyperFabric with the ServiceGuard ResourceMonitorYou can configure

Strany 12 - Publishing History

Configuring HyperFabricConfiguring HyperFabric with ServiceGuardChapter 4 95Specify Package Name and NodesSpecify Package SUBNET AddressSpecify Package

Strany 13 - What Is in This Document

xiAbout This DocumentThis document describes how to install, configure, and troubleshoot theHyperFabric product on the HP-UX 11i v2 (HP-UX 11.23) opera

Strany 14 - HP Welcomes Your Feedback

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 496Configuring HMP for Transparent LocalFailover SupportHMP supports

Strany 15 - 1 Overview of the HyperFabric

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4 97• HMP does not support backward compatibility in the local fail

Strany 16 - Chapter 12

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 498How Transparent Local Failover WorksConsider a hypothetical Hype

Strany 17 - About HyperFabric

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4 99Case 1: Adapter, Link or Switch Port Failure (see Figure 4-7)If

Strany 18 - HyperFabric Products

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4100Case 2: Switch Failure (see Figure 4-8)Consider the following i

Strany 19 - Switches and Switch Modules

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4 101Thus, if a switch fails, HMP transparently fails over traffic o

Strany 20 - Other Product Elements

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4102Configuring HMP for Transparent Local FailoverSupport - Using SA

Strany 21 - HyperFabric Concepts

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4 103of adapters clic0 and clic1 and if the Card-Pair 1, comprises

Strany 22

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4104Configuring HMP for Transparent Local FailoverSupport - Using th

Strany 23 - 2 Planning the Fabric

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4 105Using the configuration information in Figure 4-10, the informa

Strany 24

xiiHP-UX Release Name and Release IdentifierEach HP-UX 11i release has an associated release name and releaseidentifier. The uname (1) command with the

Strany 25 - Preliminary Considerations

Configuring HyperFabricConfiguring HMP for Transparent Local Failover SupportChapter 4106On node B:1. How many HyperFabric adapters are installed on the

Strany 26

Chapter 5 1075 Managing HyperFabricThis chapter contains the following sections that give information aboutmanaging HyperFabric:• “Starting HyperFabri

Strany 27

Managing HyperFabricChapter 5108• “Verifying Communications within the Fabric” on page 112.• “Displaying Status and Statistics” on page 117.• “Viewing

Strany 28 - TCP/UDP/IP

Managing HyperFabricStarting HyperFabricChapter 5 109Starting HyperFabricHyperFabric is started in one of these three ways:• As part of the normal loc

Strany 29

Managing HyperFabricStarting HyperFabricChapter 5110Using the clic_start CommandRun the clic_start command on each node to start the HyperFabricmanage

Strany 30

Managing HyperFabricStarting HyperFabricChapter 5 111When HyperFabric starts, a confirmation message displays. Also, thestatus “HyperFabric: Running” i

Strany 31 - Configuration Parameters

Managing HyperFabricVerifying Communications within the FabricChapter 5112Verifying Communications within the FabricYou can verify the communications

Strany 32

Managing HyperFabricVerifying Communications within the FabricChapter 5 113The command parameters are as follows:•node_name specifies the node you want

Strany 33

Managing HyperFabricVerifying Communications within the FabricChapter 5114NOTE Also see the clic_diag command to:Probe a specific remote node.Dump an

Strany 34

Managing HyperFabricVerifying Communications within the FabricChapter 5 115CLIC_PROBE: 256 byte packetsSource adapter id: bently6.corp3.com:clic0Targe

Strany 35

xiiiWhat Is in This DocumentHyperFabric Administrator’s Guide is divided into several chapters, eachof which contains information about installing, co

Strany 36 - Chapter 222

Managing HyperFabricVerifying Communications within the FabricChapter 5116The generated output could look like this:CLIC_PROBE: 256 byte packets sentS

Strany 37

Managing HyperFabricDisplaying Status and StatisticsChapter 5 117Displaying Status and StatisticsYou can get the status of and statistics associated w

Strany 38

Managing HyperFabricDisplaying Status and StatisticsChapter 5118Note that the second line in the above syntax is indented for readabilitypurposes only

Strany 39

Managing HyperFabricDisplaying Status and StatisticsChapter 5 119• -c displays the statistics of the adapter identified byadapter_ID.• -n displays stat

Strany 40 - Application Availability

Managing HyperFabricDisplaying Status and StatisticsChapter 5120If the local node is bently7, and you want to display themanagement daemon (clic_mgmtd

Strany 41 - Features

Managing HyperFabricDisplaying Status and StatisticsChapter 5 121The generated output could look like this:===========================================

Strany 42

Managing HyperFabricDisplaying Status and StatisticsChapter 5122Firmware reset notification: 0Data corruption notification: 0Unsupported QOS message r

Strany 43

Managing HyperFabricDisplaying Status and StatisticsChapter 5 123Frame buffer overflow: 0Receive on disabled endpoint: 0Invalid endpoint ID: 0Invalid

Strany 44

Managing HyperFabricDisplaying Status and StatisticsChapter 5124============================================================================Date: Sat

Strany 45

Managing HyperFabricDisplaying Status and StatisticsChapter 5 125The generated output if the nodes are connected through a switchcould look like this:

Strany 46 - HF2 adapters

xivNew and Changed Information in This EditionThis edition includes information about the transparent local failoverfeature of Hyper Messaging Protoco

Strany 47 - HMP Supported Configurations

Managing HyperFabricDisplaying Status and StatisticsChapter 5126============================================================================• Example

Strany 48 - Chapter 234

Managing HyperFabricViewing man PagesChapter 5 127Viewing man PagesIf you want to be able to view the HyperFabric man pages, you must firstadd /opt/cli

Strany 49

Managing HyperFabricStopping HyperFabricChapter 5128Stopping HyperFabricYou can stop HyperFabric only on a local node. Stopping HyperFabric ona node m

Strany 50

Managing HyperFabricStopping HyperFabricChapter 5 129Using SAMTo use SAM to stop HyperFabric on a local HP 9000 system runningHP-UX 11i v2, complete t

Strany 51

Managing HyperFabricStopping HyperFabricChapter 5130

Strany 52 - Chapter 238

Chapter 6 1316 Troubleshooting HyperFabricThis chapter contains these sections that describe troubleshootingHyperFabric:• “Running Diagnostics” on pag

Strany 53 - Chapter 2 39

Troubleshooting HyperFabricChapter 6132• “Using Support Tools Manager” on page 140.• “Useful Files” on page 141.• “LED Colors and Their Meanings” on p

Strany 54 - Chapter 240

Troubleshooting HyperFabricRunning DiagnosticsChapter 6 133Running DiagnosticsBefore running HyperFabric diagnostics:1. Confirm HyperFabric adapters ar

Strany 55 - 3 Installing HyperFabric

Troubleshooting HyperFabricRunning DiagnosticsChapter 6134$ clic_startAll of these commands reside in the /opt/clic/bin directory.6. Check cabling to

Strany 56 - Chapter 342

Troubleshooting HyperFabricRunning DiagnosticsChapter 6 135Make sure 4X HyperFabric adapters are installed on thenodes. The adapter type field indicate

Strany 57 - Prerequisites

Chapter 1 11 Overview of the HyperFabricProductThis chapter contains the following sections that give generalinformation about HyperFabric:

Strany 58

Troubleshooting HyperFabricRunning DiagnosticsChapter 6136Diagnostics can be run on many of the HyperFabric components by usingthe clic_diag command.

Strany 59

Troubleshooting HyperFabricRunning DiagnosticsChapter 6 137• -r specifies that you want to probe a specific remote node identifiedbyremote_node_name. The

Strany 60

Troubleshooting HyperFabricRunning DiagnosticsChapter 6138• -B specifies that you want the size (in bytes) of the trace buffer to betrace_buffer_size.

Strany 61

Troubleshooting HyperFabricRunning DiagnosticsChapter 6 139 Source adapter id: bently6.corp4.com:clic1 Target adapter id: bently8.corp2.com:clic3256

Strany 62

Troubleshooting HyperFabricUsing Support Tools ManagerChapter 6140Using Support Tools ManagerUse Support Tools Manager (STM) with HyperFabric to gathe

Strany 63

Troubleshooting HyperFabricUseful FilesChapter 6 141Useful FilesWhen you are troubleshooting HyperFabric-related problems, you mightfind it useful to l

Strany 64

Troubleshooting HyperFabricUseful FilesChapter 6142/var/adm/clic_fw.dumpxThis is the default file for a memory dump of an HyperFabricadapter, created w

Strany 65 - Installing the Software

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6 143LED Colors and Their MeaningsListed below are the possible colors (and the corres

Strany 66

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6144— The adapter is bad.— The cable is bad.— The switch port is bad (if the adapter i

Strany 67

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6 145Table 6-2 HyperFabric Adapter LED Colors and MeaningsLED Color Meaning Notes“Conn

Strany 68

Overview of the HyperFabric ProductChapter 12• “About HyperFabric” on page 3• “HyperFabric Products” on page 4• “HyperFabric Concepts” on page 7

Strany 69 - Loading the Software

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6146“Error” None Adapter is not inan errorcondition.Adapter should be operatingnormall

Strany 70

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6 147

Strany 71 - Before Installation

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6148HF2 Switch LEDsThe HF2 switch LED colors and meanings are explained below.❏ For ea

Strany 72

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6 149❏ For each port on the cards/switch module in the switch:✓ If the port is not ope

Strany 73 - Installing the HF2 Switch

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6150Table 6-3 HF2 Switch LED Colors and MeaningsLED Color Meaning Notes“Status” None T

Strany 74

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6 151“EthernetPort Main”and “EthernetPort Aux”None Ethernet port isdisconnected.This c

Strany 75

Troubleshooting HyperFabricLED Colors and Their MeaningsChapter 6152“Portx” None Port is notoperational.• A cable is not attachedcorrectly to the port

Strany 76 - (with flanges)

Troubleshooting HyperFabricDetermining Whether an Adapter or a Cable is FaultyChapter 6 153Determining Whether an Adapter or a Cable isFaultyIf you su

Strany 77

Troubleshooting HyperFabricDetermining Whether a Switch is FaultyChapter 6154Determining Whether a Switch is FaultyIf you suspect that a HyperFabric s

Strany 78

Troubleshooting HyperFabricDetermining Whether a Switch is FaultyChapter 6 155Step 4. Check the ports on the cards/switch module:a. Disconnect the cab

Strany 79

Overview of the HyperFabric ProductAbout HyperFabricChapter 1 3About HyperFabricHyperFabric is an HP high-speed, packet-based interconnect fornode-to-

Strany 80

Troubleshooting HyperFabricReplacing a HyperFabric AdapterChapter 6156Replacing a HyperFabric AdapterIf OLAR is supported for the HP 9000 system and t

Strany 81 - 4 Configuring HyperFabric

Troubleshooting HyperFabricReplacing a HyperFabric SwitchChapter 6 157Replacing a HyperFabric SwitchIf you need to replace a faulty HyperFabric switch

Strany 82

Troubleshooting HyperFabricReplacing a HyperFabric SwitchChapter 6158

Strany 83 - Configuration Overview

Appendix A 159A Safety and RegulatoryInformationThis appendix contains the following sections that contain safetyinformation and regulatory statements

Strany 84

Safety and Regulatory InformationAppendix A160components:• “Safety Symbols” on page 161.• “Regulatory Statements” on page 162.These components were te

Strany 85 - Information You Need

Safety and Regulatory InformationSafety SymbolsAppendix A 161Safety SymbolsThe safety-related symbols used in this manual are shown below.WARNING A WA

Strany 86

Safety and Regulatory InformationRegulatory StatementsAppendix A162Regulatory StatementsThis section contains the regulatory statements for the HyperF

Strany 87 - Chapter 4 73

Safety and Regulatory InformationRegulatory StatementsAppendix A 163if not installed and used in accordance with the instruction manual, maycause harm

Strany 88

Safety and Regulatory InformationRegulatory StatementsAppendix A164Radio Frequency Interference (Japan Only)VCCI, Class A (Model A4891-62001 only)

Strany 89

Safety and Regulatory InformationRegulatory StatementsAppendix A 165Declarations of Conformity

Strany 90

Overview of the HyperFabric ProductHyperFabric ProductsChapter 14HyperFabric ProductsHyperFabric hardware consists of host-based interface adapter car

Strany 91

Safety and Regulatory InformationRegulatory StatementsAppendix A166

Strany 92 - Performing the Configuration

Safety and Regulatory InformationRegulatory StatementsAppendix A 167

Strany 93 - Using the clic_init Command

Safety and Regulatory InformationRegulatory StatementsAppendix A168

Strany 94

Appendix B 169B Technical SpecificationsThis appendix contains the following sections that contain the technicalspecifications for the HyperFabric hardw

Strany 95

Technical SpecificationsAppendix B170• “Environmental” on page 173.

Strany 96

Technical SpecificationsPhysical AttributesAppendix B 171Physical AttributesThe physical attributes of the HyperFabric adapters and switches are asfoll

Strany 97

Technical SpecificationsPhysical AttributesAppendix B172• HF2 switch chassis (A6384A)— 3.47 inch (8.8 cm) height— 19 inch (48.2 cm) width (at flanges)17

Strany 98

Technical SpecificationsEnvironmentalAppendix B 173EnvironmentalThese environmental specifications are the same for the HyperFabricadapters and switches

Strany 99

Technical SpecificationsEnvironmentalAppendix B174

Strany 100

175IndexAadaptersdeconfiguring, 83, 103faulty, testing for, 153installing, 44LED colors and meanings, 143, 145OLA of, 48OLR of, 49regulatory specificati

Strany 101

Overview of the HyperFabric ProductHyperFabric ProductsChapter 1 5• HP-UX 11.0: HyperFabric software version B.11.00.09• HP-UX 11i v1: HyperFabric sof

Strany 102

Index176IP addresses, relocatable. See relocatable IPaddresses.LLEDscolors and meaningsfor adapters, 143, 145for HF2 switches, 148, 152on HF2 switches

Strany 103 - Switches)

iiLegal NoticesThe information in this document is subject to change without notice.Hewlett-Packard makes no warranty of any kind with regard to thism

Strany 104

Overview of the HyperFabric ProductHyperFabric ProductsChapter 16IMPORTANT HF2 adapters and switches are not supported by software versionsearlier tha

Strany 105

Overview of the HyperFabric ProductHyperFabric ConceptsChapter 1 7HyperFabric ConceptsThis section briefly describes some of the basic HyperFabric conc

Strany 106

Overview of the HyperFabric ProductHyperFabric ConceptsChapter 18reason (for example, if it is killed), all HyperFabric-relatedcommunications on that

Strany 107

Chapter 2 92 Planning the FabricThis chapter contains the following sections that include generalguidelines and protocol-specific considerations for pl

Strany 108

Planning the FabricChapter 210• “Preliminary Considerations” on page 11• “HyperFabric Features, Parameters and Supported Configurationsfor TCP/UDP/IP a

Strany 109

Planning the FabricPreliminary ConsiderationsChapter 2 11Preliminary ConsiderationsBefore assembling a fabric physically, do the following to address

Strany 110 - Failover Support

Planning the FabricPreliminary ConsiderationsChapter 212Step 11. Draw the cable connections from each node to switches (if the fabric willcontain swit

Strany 111

Planning the FabricHyperFabric Features, Parameters and Supported Configurations for TCP/UDP/IP and HMP ApplicationsChapter 2 13HyperFabric Features, P

Strany 112 - Card Pair 0 Card Pair 0

Planning the FabricTCP/UDP/IPChapter 214TCP/UDP/IPTCP/UDP/IP is supported on all HF2 hardware. Although some of theHyperFabric adapter cards support b

Strany 113

Planning the FabricTCP/UDP/IPChapter 2 15— Logging into a user specified log file with a choice of severity— Email to a user defined email address.For mo

Strany 114

iiiContentsAbout This Document1. Overview of the HyperFabric ProductAbout HyperFabric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 115

Planning the FabricTCP/UDP/IPChapter 216ServiceGuard uses a “heartbeat” to monitor the cluster. TheHyperFabric links cannot be used for the heartbeat.

Strany 116 - Support - Using SAM

Planning the FabricTCP/UDP/IPChapter 2 17Switch Management is not supported. Switch management will notoperate properly if you enable it on a HyperFab

Strany 117

Planning the FabricTCP/UDP/IPChapter 218You can interconnect (mesh) up to 4 switches (16-port fiber, or Mixed8 fiber ports) in a single HyperFabric cl

Strany 118

Planning the FabricTCP/UDP/IPChapter 2 19• Throughput and LatencyTable 2-1 HF2 Throughput and Latency with TCP/UDP/IP ApplicationsServer Class Maximum

Strany 119

Planning the FabricTCP/UDP/IPChapter 220Table 2-2 Supported HyperFabric Adapter ConfigurationsHFAdapterBusTypeSupportedHP SystemsHP-UXVersionOLARSuppor

Strany 120

Planning the FabricTCP/UDP/IPChapter 2 21TCP/UDP/IP Supported ConfigurationsMultiple TCP/UDP/IP HyperFabric configurations are supported tomatch the co

Strany 121 - 5 Managing HyperFabric

Planning the FabricTCP/UDP/IPChapter 222Figure 2-1 TCP/UDP/IP Point-To-Point Configurations

Strany 122

Planning the FabricTCP/UDP/IPChapter 2 23Switched ConfigurationThis configuration offers the same benefits as the point-to-pointconfigurations illustrated

Strany 123 - Starting HyperFabric

Planning the FabricTCP/UDP/IPChapter 224High Availability Switched ConfigurationThis configuration has no single point of failure. The HyperFabric drive

Strany 124 - Using SAM

Planning the FabricTCP/UDP/IPChapter 2 25Hybrid ConfigurationYou can interconnect servers and workstations in a single heterogeneousHyperFabric cluster

Strany 125

ContentsivOnline Addition and Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Planning and Preparation .

Strany 126 - The clic_probe Command

Planning the FabricHyper Messaging Protocol (HMP)Chapter 226Hyper Messaging Protocol (HMP)Hyper Messaging Protocol (HMP) is an HP patented, high perfo

Strany 127

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 27HP MPI is a native implementation of version 1.2 of theMessage-Passing Interface Standard

Strany 128

Planning the FabricHyper Messaging Protocol (HMP)Chapter 228nodes in a cluster. ServiceGuard cannot use the HyperFabricinterconnect as a heartbeat lin

Strany 129 - VRID switch_hopcount

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 29same process takes place when a resource is removed from a cluster.However, DRU is not su

Strany 130

Planning the FabricHyper Messaging Protocol (HMP)Chapter 230HyperFabric clusters running HMP applications are limited tosupporting a maximum of 64 ada

Strany 131 - The clic_stat Command

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 31• HMP is supported on A400, A500, rp2400, rp2450, rp54xx (N-class),rp74xx (L-class), rp84

Strany 132

Planning the FabricHyper Messaging Protocol (HMP)Chapter 232NOTE The local failover configuration on HMP is supported only on the A6386AHF2 adapters.

Strany 133

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 33HMP Supported ConfigurationsMultiple HMP HyperFabric configurations are supported to match

Strany 134

Planning the FabricHyper Messaging Protocol (HMP)Chapter 234Figure 2-5 HMP Point-To-Point Configurations

Strany 135 - Chapter 5 121

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 35Enterprise (Database) ConfigurationThe HMP enterprise configuration illustrated in Figure 2

Strany 136

vContents5. Managing HyperFabricStarting HyperFabric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 137

Planning the FabricHyper Messaging Protocol (HMP)Chapter 236Enterprise (Database) - Local Failover Supported ConfigurationThe HMP enterprise configurati

Strany 138 - Chapter 5124

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 37Technical Computing (Work Stations) ConfigurationThis configuration is typically used to ru

Strany 139 - Chapter 5 125

Planning the FabricHyper Messaging Protocol (HMP)Chapter 238Figure 2-8 Technical Computing Configuration

Strany 140

Planning the FabricHyper Messaging Protocol (HMP)Chapter 2 39Figure 2-9 Large Technical Computing Configuration

Strany 141 - Viewing man Pages

Planning the FabricHyper Messaging Protocol (HMP)Chapter 240

Strany 142 - Stopping HyperFabric

Chapter 3 413 Installing HyperFabricThis chapter contains the following sections that describe theHyperFabric installation:• “Checking HyperFabric Ins

Strany 143

Installing HyperFabricChapter 342• “Installing HyperFabric Adapters” on page 44.• “Installing the Software” on page 51.• “Installing HyperFabric Switc

Strany 144 - Chapter 5130

Installing HyperFabricChecking HyperFabric Installation PrerequisitesChapter 3 43Checking HyperFabric InstallationPrerequisitesBefore installing Hyper

Strany 145 - 6 Troubleshooting HyperFabric

Installing HyperFabricInstalling HyperFabric AdaptersChapter 344Installing HyperFabric AdaptersThis section contains information about installing Hype

Strany 146

Installing HyperFabricInstalling HyperFabric AdaptersChapter 3 45available on HP 9000 systems that are designed to support OLAR. Thesystem hardware us

Strany 147 - Running Diagnostics

ContentsviRadio Frequency Interference (Japan Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164Declarations of Conformity . . .

Strany 148

Installing HyperFabricInstalling HyperFabric AdaptersChapter 346Table 3-1 below explains some important OLAR-related terms.IMPORTANT In many cases, ot

Strany 149

Installing HyperFabricInstalling HyperFabric AdaptersChapter 3 47Planning and PreparationAs mentioned previously, for the most part, SAM prevents the

Strany 150 - The clic_diag Command

Installing HyperFabricInstalling HyperFabric AdaptersChapter 348Online Addition (OLA) Multiple cards can be added at the same time.When adding a card

Strany 151

Installing HyperFabricInstalling HyperFabric AdaptersChapter 3 49Online Replacement (OLR) When replacing an interface card online,the replacement card

Strany 152 - Example of clic_diag

Installing HyperFabricInstalling HyperFabric AdaptersChapter 350You are asked if you want to continue. If you reply Yes, client applicationsare suspen

Strany 153 - Chapter 6 139

Installing HyperFabricInstalling the SoftwareChapter 3 51Installing the SoftwareThis section describes the HyperFabric file structure and the stepsnece

Strany 154 - Using Support Tools Manager

Installing HyperFabricInstalling the SoftwareChapter 352The commands and files used to administer HyperFabric typically have aprefix of clic_. CLIC stan

Strany 155 - Useful Files

Installing HyperFabricInstalling the SoftwareChapter 3 53• /var/adm/OLDclic_logThe log file from the previous time the clic_start command wasexecuted.•

Strany 156

Installing HyperFabricInstalling the SoftwareChapter 354• /opt/clic/firmware/clic_fw_4x8cThe 4X PCI HyperFabric 8-bit CRC firmware. This file must not b

Strany 157 - LED Colors and Their Meanings

Installing HyperFabricInstalling the SoftwareChapter 3 55Loading the SoftwareListed below are the steps you must follow to load the HyperFabricsoftwar

Strany 158

FiguresviiFigure 2-1. TCP/UDP/IP Point-To-Point Configurations . . . . . . . . . . . . . . . . . . . . . . 22Figure 2-2. TCP/UDP/IP Basic Switched Confi

Strany 159

Installing HyperFabricInstalling the SoftwareChapter 356swinstall loads the fileset, runs the control script for the filesets, andbuilds the kernel. Whe

Strany 160 - Chapter 6146

Installing HyperFabricInstalling HyperFabric SwitchesChapter 3 57Installing HyperFabric SwitchesThis section contains the information you need to inst

Strany 161 - Chapter 6 147

Installing HyperFabricInstalling HyperFabric SwitchesChapter 358— If your cables have dust caps over the connectors, keep them inplace until you are r

Strany 162 - HF2 Switch LEDs

Installing HyperFabricInstalling HyperFabric SwitchesChapter 3 59Installing the HF2 SwitchThis section contains information on installing an HF2 switc

Strany 163

Installing HyperFabricInstalling HyperFabric SwitchesChapter 360Figure 3-3 shows the front of the HF2 switch with an A6389A HF2 4-portcopper switch mo

Strany 164 - Chapter 6150

Installing HyperFabricInstalling HyperFabric SwitchesChapter 3 61With the Rail KitAs mentioned earlier, HP strongly recommends installing the HF2switc

Strany 165 - Chapter 6 151

Installing HyperFabricInstalling HyperFabric SwitchesChapter 362sliding the switch. If so, try lifting the switch over the rail screws. If youcannot d

Strany 166

Installing HyperFabricInstalling HyperFabric SwitchesChapter 3 63the flat part). Otherwise, the brackets will not secure the back of theswitch properly

Strany 167

Installing HyperFabricInstalling HyperFabric SwitchesChapter 364Step 9. Plug the switch’s power cord into the rack’s PDU, if it has one.Alternatively,

Strany 168 - HF2 Switch

Installing HyperFabricInstalling HyperFabric SwitchesChapter 3 65Without the Rail KitAs mentioned earlier, HP strongly recommends installing the HF2sw

Strany 169

Figuresviii

Strany 170

Installing HyperFabricInstalling HyperFabric SwitchesChapter 366Step 10. Once the power is on, check these LEDs on the integrated Ethernetmanagement L

Strany 171

Chapter 4 674 Configuring HyperFabricThis chapter contains the following sections that describe configuringHyperFabric:• “Configuration Overview” on page

Strany 172 - Chapter 6158

Configuring HyperFabricChapter 468• “Information You Need” on page 71.• “Performing the Configuration” on page 78.• “Deconfiguring a HyperFabric Adapter

Strany 173 - Information

Configuring HyperFabricConfiguration OverviewChapter 4 69Configuration OverviewYou do not need to configure the HyperFabric switch because theHyperFabric

Strany 174

Configuring HyperFabricConfiguration OverviewChapter 470IMPORTANT In this file, clic_init and SAM add some HyperFabric-related linesthat end with the cha

Strany 175 - Safety Symbols

Configuring HyperFabricInformation You NeedChapter 4 71Information You NeedWhen you run the clic_init command or use SAM for configuration,you have to p

Strany 176 - Regulatory Statements

Configuring HyperFabricInformation You NeedChapter 472✓ The IP address of the switch.✓ The MAC address of the switch’s Ethernet port. If you do notalre

Strany 177 - Europe RFI Statement

Configuring HyperFabricInformation You NeedChapter 4 73IP_addressbently6.corp3.com bently6IP_addressbently4.corp7.com test1IP_addressbently2.corp4.com

Strany 178 - Appendix A164

Configuring HyperFabricInformation You NeedChapter 474Configuration Information ExampleThis example uses some “dummy” (that is, not valid) addresses to

Strany 179 - Declarations of Conformity

Configuring HyperFabricInformation You NeedChapter 4 75Using the configuration information in Figure 4-1, the information youwould specify when you run

Strany 180 - Appendix A166

TablesixTable 1. HP-UX 11i Releases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiiTable 2. Publishing His

Strany 181 - Appendix A 167

Configuring HyperFabricInformation You NeedChapter 47612. What is the Ethernet hardware address of the second switch?(0060b0d00256)13. What is the Mult

Strany 182 - Appendix A168

Configuring HyperFabricInformation You NeedChapter 4 7712. What is the Ethernet hardware address of the second switch?(0060b0d00256)13. What is the Mul

Strany 183 - B Technical Specifications

Configuring HyperFabricPerforming the ConfigurationChapter 478Performing the ConfigurationAs explained in “Configuration Overview” on page 69, you must cr

Strany 184 - Appendix B170

Configuring HyperFabricPerforming the ConfigurationChapter 4 79Using the clic_init CommandRun the clic_init command to create the global configuration fil

Strany 185 - Physical Attributes

Configuring HyperFabricPerforming the ConfigurationChapter 480If you do not specify any of the above parameters, the online help forclic_init is display

Strany 186

Configuring HyperFabricPerforming the ConfigurationChapter 4 81Using SAMThis section describes how to use SAM to configure HyperFabric. Forinformation on

Strany 187 - Environmental

Configuring HyperFabricPerforming the ConfigurationChapter 482• Subnet Mask—Optional. The adapter’s subnet mask. If you do notspecify this, a default ma

Strany 188 - Appendix B174

Configuring HyperFabricDeconfiguring a HyperFabric Adapter with SAMChapter 4 83Deconfiguring a HyperFabric Adapter withSAMTo use SAM to deconfigure a Hype

Strany 189

Configuring HyperFabricDeconfiguring a HyperFabric Adapter with SAMChapter 484is informed and the card pair entry is removed from the/etc/rc.config.d/ne

Strany 190

Configuring HyperFabricConfiguring the HyperFabric EMS MonitorChapter 4 85Configuring the HyperFabric EMS MonitorIn the HyperFabric version B.11.23.01, t