Audible Warnings
HP NetRAID has an onboard tone generator that indicates events and errors.
Tone Pattern
Meaning Examples
Three seconds on and
one second off
A logical drive is offline. One or more drives in a RAID 0
configuration failed.
Two or more drives in a RAID 1, 3,
or 5 configuration failed.
One second on and one
second off
A logical drive is running
in degraded mode.
One drive in a RAID 3 or 5
configuration failed.
One second on and
three seconds off
An automatically initiated
rebuild has been
completed.
While you were away from the
system, a disk drive in a RAID 1, 3,
or 5 configuration failed and was
rebuilt.