Table 5 Configuration Options and Descriptions
Item UI
Reference
Possible Values Description
File(s) to be
included in the
alert definition.
Alert Admin All Files or Specific
filename (Maximum 8
character
alphanumeric string).
(Default is All Files)
This is used to indicate if all files will be checked for
meeting the alert criteria or just a specific file. Also,
the severity level for this alert criterion could be
specified.
File security &
severity level.
Alert Admin Any 4 letter
combination out of
(A, N, G, C, U, O, -)
Not selected by
default.
An alert is generated if the specified file security
does not match the security of the files in the
specified location. Also, the severity level
for this
alert criterion could be specified.
Auto reset for file
security.
Alert Admin YES/ NO – by
checking/un-checking
the option. Not
selected by default.
If an alert is generated matching the previous
criterion and this option is enabled, it will change
the security of the file that was generated to the
security level that was specified, give that the user
has admin rights.
File ownership &
severity level.
Alert Admin Should be specified
as group. user or
groupID, userID
Not selected by
default.
An alert is generated if the specified file ownership
does not match the ownership of the files in the
specified location. Also, the severity level
for this
alert criterion could be specified.
Auto reset for file
ownership.
Alert Admin YES/ NO – by
checking/un-checking
the option. Not
selected by default.
If an alert is generated matching the previous
criterion and this option is enabled, it will change
the owner of the file that was generated to the
owner that was specified, give that the user has
admin rights.
File EOF
threshold.
Alert Admin
Positive Integer (0-
10000). Not selected
by default.
This is the End of File value for the file, if there is a
file exceeds the specified EOF value, alert
notification is generated. Also, the severity level for
this alert criterion could be specified.
Missing file notice
& severity level.
Alert Admin
YES/ NO – by
checking/un-checking
the option. Not
selected by default.
This is the notification if file is missing. Also, the
severity level
for this alert criterion could be
specified.
Corrupt file notice
& severity level.
Alert Admin
YES/ NO – by
checking/un-checking
the option. Not
selected by default.
This is the notification if file is corrupted. Also, the
severity level
for this alert criterion could be
specified.
Modified file
notice & severity
level.
Alert Admin
YES/ NO – by
checking/un-checking
the option. Not
selected by default.
This is the notification if file has been modified.
Also, the severity level
for this alert criterion could
be specified.
Auto increment
max extents
value.
Alert Admin
Positive Integer
Not selected by
default.
This is the number of file extents that need to be
increased if the file usage reaches a particular
percent.
Disk to exclude
from alerts.
Alert Admin
Selected disk from a
list of available disk
names.
This is used to specify the disk for which the alerts
are NOT to be generated.
Sub volume to
exclude from
alerts.
Alert Admin
Selected sub volume
from a list of available
sub volume names.
This is used to specify the sub volume for which the
alerts are NOT to be generated
File(s) to be
excluded from the
alert.
Alert Admin
All Files or Specific
filename (Maximum 8
character
alphanumeric string).
(Default is All Files)
This is used to indicate if all files will be excluded
from the alert or just a specific file.
Zobrazit stránku 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 113 114

Komentáře k této Příručce

Žádné komentáře