HP ProLiant BL465c G6 Server Blade User Guide Part Number 574424-001 June 2009 (First Edition)
Component identification 10 Item Description 13 DIMM slots (Processor 2 memory banks C and D) 14 HP Smart Array E200i cache module (under hard dri
Component identification 11 Position Function Default 8 Reserved Off *To access redundant ROM, set S1, S5, and S6 to ON. HP c-Class Blade SUV C
Operations 12 Operations Power up the server blade The Onboard Administrator initiates an automatic power-up sequence when the server blade is instal
Operations 13 • Use the Onboard Administrator GUI to initiate a shutdown: a. Select the Enclosure Information tab, then select the Overall checkbox
Operations 14 Remove the access panel To remove the component: 1. Power down the server blade (on page 12). 2. Remove the server blade (on page 13)
Setup 15 Setup Overview Installation of a server blade requires the following steps: 1. Install and configure an HP BladeSystem c-Class enclosure. 2
Setup 16 Interconnect bay numbering and device mapping • HP BladeSystem c7000 Enclosure To support network connections for specific signals, instal
Setup 17 • HP BladeSystem c3000 Enclosure and Tower Enclosure Server blade signal Interconnect bay number Interconnect bay label Notes NICs 1,
Setup 18 Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-thru modules and switch modules. For more inform
Setup 19 3. Prepare the server blade for installation. 4. Install the server blade. Completing the configuration To complete the server blade and
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties
Hardware options installation 20 Hardware options installation Introduction If more than one option is being installed, read the installation instruc
Hardware options installation 21 2. Prepare the hard drive. 3. Install the hard drive. 4. Determine the status of the hard drive from the hot-plu
Hardware options installation 22 CAUTION: To avoid damage to the processor: • Handle the processor only by the edges. • Do not touch the bottom
Hardware options installation 23 5. Remove the processor socket protective cover. Retain the cover for future use. CAUTION: Failure to completel
Hardware options installation 24 7. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. 8. Al
Hardware options installation 25 9. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove
Hardware options installation 26 11. Remove the thermal interface protective cover from the heatsink. 12. Align the slot in the heatsink with the t
Hardware options installation 27 Memory options You can expand server memory by installing PC2-5300 Registered DDR2 SDRAM DIMMs. The server supports
Hardware options installation 28 DIMM population order Configuration Bank A 1A and 2A Bank B 3B and 4B Bank C 5C and 6C Bank D 7D and 8D Single proc
Hardware options installation 29 6. Install the DIMM. 7. Install the air baffles. 8. Install the access panel (on page 14). 9. Install the server
Contents 3 Contents Component identification...
Hardware options installation 30 4. Remove the mezzanine connector cover. 5. Install the mezzanine card. Press down on the connector to seat the bo
Hardware options installation 31 5. Remove the hard drive backplane. 6. Remove the front panel/hard drive cage assembly. 7. Remove the USB key, i
Hardware options installation 32 8. Remove the Smart Array E200i cache module. 9. Install the Smart Array E200i battery pack on the new cache modul
Hardware options installation 33 10. Install the Smart Array E200i cache module. 11. Install the USB key, if necessary. 12. Install the front pane
Cabling 34 Cabling Using the HP c-Class Blade SUV Cable The HP c-Class Blade SUV Cable enables the user to perform server blade administration, confi
Cabling 35 4. Connect a USB keyboard to the second USB connector. Item Description 1 Monitor 2 USB mouse 3 USB keyboard 4 HP c-Class Blade SUV
Cabling 36 Item Description 1 Monitor 2 USB CD/DVD-ROM drive or diskette drive 3 USB keyboard 4 USB hub 5 USB mouse 6 Local I/O cable
Software and configuration utilities 37 Software and configuration utilities Server blade deployment tools Software drivers and additional component
Software and configuration utilities 38 To connect to the server blade using iLO 2, install the server blade in an enclosure. Onboard Administrator
Software and configuration utilities 39 o TCP/IP networking and an IP address compatible with one of the following: the iLO 2 Diagnostic Port IP add
Contents 4 Software drivers and additional components... 37 HP Blad
Software and configuration utilities 40 Deployment methods Three primary deployment methods are supported: IMPORTANT: To deploy a server blade w
Software and configuration utilities 41 Using SmartStart technology, the Scripting Toolkit provides a flexible way to create standard server configu
Software and configuration utilities 42 4. After the server blade boots, follow the normal installation procedure for an OS. Windows Server™ 2003 ca
Software and configuration utilities 43 Creating a boot diskette The SmartStart Scripting Toolkit provides the tools and information for creating a
Software and configuration utilities 44 • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Doc
Software and configuration utilities 45 primary boot controller), execute RBSU by pressing the F9 key when prompted. After the settings are selected
Software and configuration utilities 46 also compatible with certain third-party SAN products. For more information, refer to the documentation that
Software and configuration utilities 47 • Setting the controller to be the boot controller If you do not use the utility, ORCA will default to the
Software and configuration utilities 48 For more information about iLO 2 features (which may require an iLO Advanced Pack or iLO Advanced for BladeS
Software and configuration utilities 49 HP ProLiant Essentials Virtualization Management Software The ProLiant Essentials Virtual Machine Management
Contents 5 Server fault indications flowchart ... 6
Software and configuration utilities 50 The software installed by Insight Control Environment suites delivers core management functionality for HP P
Software and configuration utilities 51 Internal USB functionality An internal USB connector is available for use with security key devices and USB
Software and configuration utilities 52 NOTE: The current version of SmartStart provides the memory spare part numbers for the server blade. To d
Software and configuration utilities 53 • For midsize and large environments: HP Insight Remote Support Pack (formerly Service Essentials Remote Su
Software and configuration utilities 54 System Online ROM flash component utility The Online ROM Flash Component Utility enables system administrato
Troubleshooting 55 Troubleshooting Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common p
Troubleshooting 56 Important safety information Familiarize yourself with the safety information in the following sections before troubleshooting the
Troubleshooting 57 WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair proce
Troubleshooting 58 6. Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, necess
Troubleshooting 59 • Server blade power-on problems flowchart (on page 62) • POST problems flowchart (on page 64) • OS boot problems flowchart (on
Component identification 6 Component identification Front panel components Item Description 1 Hard drive bay 1 2 Power On/Standby button 3 SU
Troubleshooting 60 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of
Troubleshooting 61 Item See 5 "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Docu
Troubleshooting 62 Server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber.
Troubleshooting 63 • The health LED is red or amber. NOTE: For the location of server LEDs and information on their statuses, refer to the serv
Troubleshooting 64 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system atte
Troubleshooting 65 Item Refer to 1 Server blade power-on problems flowchart (on page 62) 2 "POST error messages and beep codes (on page 70
Troubleshooting 66 OS boot problems flowchart There are two ways to use SmartStart when diagnosing OS boot problems on a server blade: • Use iLO
Troubleshooting 67 Possible causes: • Corrupted OS • Hard drive subsystem problem • Incorrect boot order setting in RBSU Item See 1 HP ROM-Ba
Troubleshooting 68 * See the server blade OS boot problems flowchart (on page 66) Server fault indications flowchart Symptoms: • Server boots, but
Troubleshooting 69 NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation. Possible causes:
Component identification 7 Front panel LEDs Item Description Status 1 UID LED Blue = Identified Blue flashing = Active remote management Off
Troubleshooting 70 POST error messages and beep codes Introduction to POST error messages The error messages and codes in this section include all
Troubleshooting 71 For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting
Battery replacement 72 Battery replacement If the server blade no longer automatically displays the correct date and time, you may need to replace t
Regulatory compliance notices 73 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance
Regulatory compliance notices 74 energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
Regulatory compliance notices 75 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Cana
Regulatory compliance notices 76 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other
Regulatory compliance notices 77 Class B equipment Chinese notice Class A equipment Laser compliance This product may be provided with an optica
Regulatory compliance notices 78 Batteries, battery packs, and accumulators should not be disposed of together with the general household waste.
Electrostatic discharge 79 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo
Component identification 8 SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 2 Online LED (green) SAS and SATA h
Specifications 80 Specifications Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shippin
Technical support 81 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su
Technical support 82 • Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, howev
Technical support 83 Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations
Technical support 84 HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das
Technical support 85 el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de compo
Technical support 86 • Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas
Technical support 87
Technical support 88
Acronyms and abbreviations 89 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ADU Array Diagnostics Utility AMP Adv
Component identification 9 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation Flashing irregularly Amber, flashing regularly (1
Acronyms and abbreviations 90 IML Integrated Management Log NBP Network Bootstrap Program ORCA Option ROM Configuration for Arrays PCIe periphera
Index 91 A access panel 14 ACU (Array Configuration Utility) 45 ADU (Array Diagnostic Utility) 52 ASR (Automatic Server Recovery) 47 Automati
Index 92 HP ProLiant Essentials Virtualization Management Software 49 HP Systems Insight Manager, overview 48 HP technical support 81 I identif
Index 93 scripted installation 40 SD support 51 serial label pull tab 6 serial number 46 series number 73 server blade handle 6 server bl