Hp ProLiant DL320 G3 Server Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Hp ProLiant DL320 G3 Server. HP ProLiant DL320 G3 Server User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 119
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User Guide

HP ProLiant DL320 Generation 3 Server User Guide March 2005 (Second Edition) Part Number 374263-002

Strany 2 - Audience assumptions

10 HP ProLiant DL320 Generation 3 Server User Guide Rear panel components Item Description 1 PCI-X expansion slot 2, full-length 64 bit/133 MH

Strany 3 - Contents

100 HP ProLiant DL320 Generation 3 Server User Guide • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 • 1-

Strany 4

Regulatory compliance notices 101 Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Ca

Strany 5

102 HP ProLiant DL320 Generation 3 Server User Guide *Notified body number (used only if applicable—refer to the product label) Japanese notice

Strany 6

Regulatory compliance notices 103 Korean notice A&B Class A equipment Class B equipment Laser compliance This product may be provided with a

Strany 7 - Front panel components

104 HP ProLiant DL320 Generation 3 Server User Guide • Do not try to open the module enclosure. There are no user-serviceable components inside.

Strany 8 - Front panel LEDs and buttons

Regulatory compliance notices 105 Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordanc

Strany 10 - Rear panel components

107 Server specifications In this section Environmental specifications ...

Strany 11 - Rear panel LEDs and buttons

108 HP ProLiant DL320 Generation 3 Server User Guide Input requirement Specification Rated input voltage 100 VAC to 240 VAC Rated input frequenc

Strany 12 - System board components

109 Technical support In this section Related documents...

Strany 13 - System maintenance switch

Server component identification 11 Rear panel LEDs and buttons Item Description Status 1 iLO activity Green = Activity exists. Flashing gr

Strany 14 - System board LEDs

110 HP ProLiant DL320 Generation 3 Server User Guide Customer self repair What is customer self repair? HP's customer self-repair program off

Strany 15

111 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery DDR double data rate DU driv

Strany 16

112 HP ProLiant DL320 Generation 3 Server User Guide IML Integrated Management Log IPL initial program load IRQ interrupt request MPS multi-pro

Strany 17 - Internal USB connector

Acronyms and abbreviations 113 PCI-X peripheral component interconnect extended PDU power distribution unit POST Power-On Self Test PPM Proces

Strany 18 - Fan module location

114 HP ProLiant DL320 Generation 3 Server User Guide SDRAM synchronous dynamic RAM SIM Systems Insight Manager SIMM single inline memory module

Strany 19 - Server operations

Acronyms and abbreviations 115 WOL Wake-on LAN

Strany 21 - Removing the access panel

117 Index A access panel 22 additional information 93, 109 ADU (Array Diagnostic Utility) 64 Altiris Deployment Solution 55 Altiris eXpr

Strany 22 - Installing the access panel

118 HP ProLiant DL320 Generation 3 Server User Guide grounding requirements 32 H hard drive blanks 40 hard drive, replacing 41 hard drives

Strany 23 - Server operations 23

Index 119 powering down 19 powering up 19, 35, 53 preparation procedures 20 problem diagnosis 71, 77 ProLiant Support Packs 66 PSPs, ove

Strany 24

12 HP ProLiant DL320 Generation 3 Server User Guide System board components Item Description Item Description 1 Rear USB connectors (2) 16

Strany 25 - Removing the fan assembly

Server component identification 13 Item Description Item Description 15 Power connector * Designations if the optional PCI riser board is ins

Strany 26 - Installing the fan assembly

14 HP ProLiant DL320 Generation 3 Server User Guide NMI switch The NMI switch allows administrators to perform a memory dump before performing a h

Strany 27 - Server setup

Server component identification 15 Item LED Description Status 3 Overtemperature Amber = System has reached a cautionary or critical temperatu

Strany 28 - Rack planning resources

16 HP ProLiant DL320 Generation 3 Server User Guide System LED and Color Internal Health LED Color Status Processor failure (Amber) Red One or m

Strany 29 - Optimum environment

Server component identification 17 Internal USB connector For more information, refer to "Internal USB Functionality (on page 63)." S

Strany 30 - Temperature requirements

18 HP ProLiant DL320 Generation 3 Server User Guide Item SCSI ID SATA Device Number 2 1 2 Fan module location

Strany 31 - Power requirements

19 Server operations In this section Powering up the server ...

Strany 32 - Rack warnings

© Copyright 2004, 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warran

Strany 33 - Installing hardware options

20 HP ProLiant DL320 Generation 3 Server User Guide 3. If the server is installed in a rack, press the UID LED button on the front panel. Blue LE

Strany 34

Server operations 21 Extending the server from the rack NOTE: If the optional cable management arm option is installed, you can extend the server

Strany 35 - Server setup 35

22 HP ProLiant DL320 Generation 3 Server User Guide 1. Power down the server if the standard cable management solution is installed ("Poweri

Strany 36 - Registering the server

Server operations 23 c. Lift the front of the assembly slightly and unseat the riser boards from the PCI riser board connectors. Installing PCI

Strany 37 - Memory options

24 HP ProLiant DL320 Generation 3 Server User Guide 2. Tighten the two PCI riser board assembly thumbscrews. Removing the hot-plug SATA backpla

Strany 38 - Installing DIMMs

Server operations 25 Removing the fan assembly 1. Power down the server ("Powering down the server" on page 19). 2. Extend the server f

Strany 39 - Hard drive options

26 HP ProLiant DL320 Generation 3 Server User Guide Installing the fan assembly

Strany 40 - Installing a SATA hard drive

27 Server setup In this section Optional installation services...

Strany 41

28 HP ProLiant DL320 Generation 3 Server User Guide – HP ProLiant Essentials (HP SIM and RDP) • Startup and implementation services for both har

Strany 42

Server setup 29 Optimum environment When installing the server in a rack, select a location that meets the environmental standards described in t

Strany 43

3 Contents Server component identification 7 Front panel components...

Strany 44

30 HP ProLiant DL320 Generation 3 Server User Guide CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow ra

Strany 45

Server setup 31 Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the instal

Strany 46

32 HP ProLiant DL320 Generation 3 Server User Guide Electrical grounding requirements The server must be grounded properly for proper operation an

Strany 47 - Server cabling

Server setup 33 WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack: • At least two people are needed to

Strany 48 - SATA cable routing

34 HP ProLiant DL320 Generation 3 Server User Guide Installing the server into the rack To install the server into a rack with square, round, or t

Strany 49 - SCSI cable routing

Server setup 35 Item Description 4 UID button/LED 5 10/100/1000 NIC 1 6 10/100/1000 NIC 2 7 iLO management port 8 Serial connector 9 Mouse con

Strany 50

36 HP ProLiant DL320 Generation 3 Server User Guide Two methods are available to install an OS on the server: • SmartStart assisted installation—

Strany 51 - Configuration tools

37 Hardware options installation In this section Introduction ...

Strany 52

38 HP ProLiant DL320 Generation 3 Server User Guide DIMM installation guidelines Observe the following guidelines when installing additional memo

Strany 53 - HP ROM-Based Setup Utility

Hardware options installation 39 2. Open the DIMM slot latches. 3. Install the DIMM. 4. Install the access panel ("Installing the access

Strany 54 - Array Configuration Utility

4 HP ProLiant DL320 Generation 3 Server User Guide Installing hardware options...

Strany 55

40 HP ProLiant DL320 Generation 3 Server User Guide Removing a hard drive blank CAUTION: To prevent improper cooling and thermal damage, do not

Strany 56 - Management tools

Hardware options installation 41 NOTE: Depending on the model purchased, the server or hard drive may look slightly different than the illustrat

Strany 57 - ROMPaq utility

42 HP ProLiant DL320 Generation 3 Server User Guide 5. Place the hard drive into the hard drive tray, and secure by fastening four screws into th

Strany 58

Hardware options installation 43 Installing the CD-ROM drive assembly CAUTION: To prevent improper cooling and thermal damage, do not operate

Strany 59 - Erase Utility

44 HP ProLiant DL320 Generation 3 Server User Guide 4. Press the latch release tabs and remove the blank. 5. Install the CD-ROM drive into the

Strany 60 - HP Systems Insight Manager

Hardware options installation 45 6. Install the optical drive assembly in the empty bay, and reinstall the thumbscrew. 7. Install the fan asse

Strany 61 - Redundant ROM support

46 HP ProLiant DL320 Generation 3 Server User Guide 1. Access the internal server components ("Preparation procedures" on page 20). 2.

Strany 62

47 Server cabling In this section Cabling overview...

Strany 63 - Diagnostic tools

48 HP ProLiant DL320 Generation 3 Server User Guide IMPORTANT: Route the cables without blocking the airflow or other installed components. Use t

Strany 64 - Integrated Management Log

Server cabling 49 SCSI cable routing CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinc

Strany 65 - Keeping the system current

Contents 5 Diagnostic tools ...

Strany 67 - Care Pack

51 Server software and configuration utilities In this section Configuration tools...

Strany 68

52 HP ProLiant DL320 Generation 3 Server User Guide • Testing server hardware using the Insight Diagnostics Utility ("HP Insight Diagnostics

Strany 69 - Battery replacement

Server software and configuration utilities 53 Configuration Replication Utility ConRep is shipped in the SmartStart Scripting Toolkit and is a p

Strany 70 - 5. Remove the battery

54 HP ProLiant DL320 Generation 3 Server User Guide To navigate RBSU, use the following keys: • To access RBSU, press the F9 key during power up

Strany 71 - Troubleshooting

Server software and configuration utilities 55 • Suggests the optimum configuration for an unconfigured system • Provides different operating m

Strany 72 - Important safety information

56 HP ProLiant DL320 Generation 3 Server User Guide 3. Select Serial Number. The following warning is displayed: WARNING! WARNING! WARNING! The

Strany 73 - Warnings and cautions

Server software and configuration utilities 57 Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic o

Strany 74

58 HP ProLiant DL320 Generation 3 Server User Guide IMPORTANT: This utility supports operating systems that may not be supported by the server. F

Strany 75 - Troubleshooting 75

Server software and configuration utilities 59 To run iLO RBSU: 1. Restart or power up the server. 2. Press the F8 key when prompted during POS

Strany 76 - Symptom information

6 HP ProLiant DL320 Generation 3 Server User Guide Declaration of conformity for products marked with the FCC logo, United States only...

Strany 77 - Diagnostic steps

60 HP ProLiant DL320 Generation 3 Server User Guide Run the Erase Utility if you need to erase the system for the following reasons: • You want t

Strany 78 - Start diagnosis flowchart

Server software and configuration utilities 61 Redundant ROM support The server enables you to upgrade or configure the ROM safely with redundant

Strany 79 - Troubleshooting 79

62 HP ProLiant DL320 Generation 3 Server User Guide 4. Install the access panel ("Installing the access panel" on page 22). 5. Power u

Strany 80 - General diagnosis flowchart

Server software and configuration utilities 63 • DOS • Operating environments which do not provide native USB support For more information on

Strany 81 - Troubleshooting 81

64 HP ProLiant DL320 Generation 3 Server User Guide If a significant change occurs between data-gathering intervals, the Survey Utility marks the

Strany 82 - Power-on problems flowchart

Server software and configuration utilities 65 You can view recorded events in the IML in several ways, including the following: • From within

Strany 83 - Troubleshooting 83

66 HP ProLiant DL320 Generation 3 Server User Guide NOTE: If you are installing drivers from the SmartStart CD or the Software Maintenance CD, re

Strany 84

Server software and configuration utilities 67 For more information, refer to the HP website (http://h18023.www1.hp.com/solutions/pcsolutions/pcn

Strany 86

69 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provid

Strany 87 - OS boot problems flowchart

7 Server component identification In this section Front panel components...

Strany 88

70 HP ProLiant DL320 Generation 3 Server User Guide 5. Remove the battery. IMPORTANT: Replacing the system board battery resets the system ROM

Strany 89 - Troubleshooting 89

71 Troubleshooting In this section Server diagnostic steps ...

Strany 90

72 HP ProLiant DL320 Generation 3 Server User Guide Important safety information Familiarize yourself with the safety information in the following

Strany 91 - Troubleshooting 91

Troubleshooting 73 This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury

Strany 92

74 HP ProLiant DL320 Generation 3 Server User Guide WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: •

Strany 93 - Other information resources

Troubleshooting 75 • Observe local occupation health and safety requirements and guidelines for manual handling. • Obtain adequate assistance to

Strany 94

76 HP ProLiant DL320 Generation 3 Server User Guide 5. Disconnect any peripheral devices not required for testing (any devices not necessary to p

Strany 95 - Electrostatic discharge

Troubleshooting 77 Service notifications To find out the latest service notifications, refer to the HP website (http://www.hp.com/products/servers/

Strany 96

78 HP ProLiant DL320 Generation 3 Server User Guide The available flowcharts include: • Start diagnosis flowchart (on page 78) • General diagnos

Strany 97

Troubleshooting 79

Strany 98 - Class A equipment

8 HP ProLiant DL320 Generation 3 Server User Guide Item Description 4 Diskette drive bay 5 Optical device bay 6 Front USB port 7 Power button F

Strany 99 - Class B equipment

80 HP ProLiant DL320 Generation 3 Server User Guide General diagnosis flowchart The General diagnosis flowchart provides a generic approach to tro

Strany 101

82 HP ProLiant DL320 Generation 3 Server User Guide Power-on problems flowchart Symptoms: • The server does not power on. • The system power LED

Strany 102 - BSMI notice

Troubleshooting 83 Item Refer to 7 • "Power Supply Problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentati

Strany 103 - Laser compliance

84 HP ProLiant DL320 Generation 3 Server User Guide

Strany 104 - Battery replacement notice

Troubleshooting 85 POST problems flowchart Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system attemp

Strany 105

86 HP ProLiant DL320 Generation 3 Server User Guide

Strany 106

Troubleshooting 87 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Sma

Strany 107 - Server specifications

88 HP ProLiant DL320 Generation 3 Server User Guide Item Refer to 8 • "Hardware Problems" in the HP ProLiant Servers Troubleshooting Gu

Strany 108 - Specification

Troubleshooting 89

Strany 109 - Technical support

Server component identification 9 Item Description Status 3 NIC 1 link/activity LED Green = Network link exists. Flashing green = Network link

Strany 110 - Customer self repair

90 HP ProLiant DL320 Generation 3 Server User Guide Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by

Strany 111 - Acronyms and abbreviations

Troubleshooting 91 Item Refer to 8 • "Hardware Problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation C

Strany 112

92 HP ProLiant DL320 Generation 3 Server User Guide

Strany 113

Troubleshooting 93 Other information resources For additional troubleshooting information, refer to the HP ProLiant Servers Troubleshooting Guide o

Strany 115 - Wake-on LAN

95 Electrostatic discharge In this section Preventing electrostatic discharge ...

Strany 116

96 HP ProLiant DL320 Generation 3 Server User Guide Grounding methods to prevent electrostatic discharge Several methods are used for grounding. U

Strany 117

97 Regulatory compliance notices In this section Regulatory compliance identification numbers...

Strany 118

98 HP ProLiant DL320 Generation 3 Server User Guide Federal Communications Commission notice Part 15 of the Federal Communications Commission (FCC

Strany 119

Regulatory compliance notices 99 Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device,

Komentáře k této Příručce

Žádné komentáře