Rated input power
590 W at 115 V AC input
570 W at 230 V AC input
BTUs per hour
2044 at 100 V AC input
2013 at 115 V AC input
2004 at 200 V AC input
1941 at 230 V AC input
Power supply output
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
HP ProLiant 460 W CS power supply (94% efficiency)
Specification Value
Input requirements
Rated input voltage
100 to 240 VAC
Rated input frequency
47 Hz to 63 Hz
Rated input current
8 A
Rated input power
509 W at 115V AC input
495 W at 230V AC input
Btus per hour
1764 at 100V AC input
1736 at 115V AC input
1694 at 200V AC input
1687 at 230V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Maximum peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
HP ProLiant 750 W CS hot-plug power supply (94% efficiency)
Specification Value
Input requirements
Rated input voltage
100 V AC240 V AC
Rated input frequency
50 Hz60 Hz
Rated input current
9 A4.5 A
Maximum rated input power
831 W at 115 V AC input
808 W at 230 V AC input
Btus per hour
2878 at 100 V AC input
2834 at 115 V AC input
2769 at 200 V AC input
2758 at 230 V AC input
Power supply output
Rated steady-state power
750 W at 100 V to 120 V AC input