Zobrazit stránku 27
Setup 28
HP BladeSystem c3000 Enclosure
To support network connections for specific signals, install an interconnect module in the bay
corresponding to the embedded NIC or mezzanine signals.
Server blade signal c7000 interconnect bay c3000 interconnect bay Interconnect bay labels
NIC 1 (Embedded) 1 1
NIC 2 (Embedded) 2 1
NIC 3 (Embedded) 1 1
NIC 4 (Embedded) 2 1
Mezzanine 1 3 and 4 2
Mezzanine 2 5 and 6 3 and 4
7 and 8 3 and 4
Mezzanine 3 5 and 6 3 and 4
7 and 8 3 and 4
For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the
HP BladeSystem enclosure setup and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure must be configured with network
interconnect devices to manage signals between the server blades and the external network.
Two types of interconnect modules are available for HP BladeSystem c-Class enclosures: Pass-Thru
modules and switch modules. For more information about interconnect module options, see the HP
website (http://www.hp.com/go/bladesystem/interconnects
).
IMPORTANT: To connect to a network with a Pass-Thru module, always connect the Pass-Thru
module to a network device that supports Gigabit speed.