HP 8591C Uživatelský manuál Strana 263

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 550
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 262
I
-
Making Measurements Using Spectrum Analyzer Mode
Percent Amplitude Modulation Measurement
Example: Use the % AM function to make a measurement.
1. Press
I-1.
Connect a signal with amplitude modulation, to the
spectrum analyzer’s INPUT 75
62.
2. Press [FREQUENCY) and enter the frequency of your input signal to place
the signal at the spectrum analyzer center frequency.
3. Press
ISPAN).
Change the span until only the signal and its two sidebands
appear on the display.
4.
Press
(mEAS/US
and
%
AM ON OFF (ON) to activate the percent
amplitude modulation function.
5. Read the measurement results in the upper left corner of the screen.
6. Press
%
AM
ON
OFF (OFF) to turn the measurement off.
5-63
Zobrazit stránku 262
1 2 ... 258 259 260 261 262 263 264 265 266 267 268 ... 549 550

Komentáře k této Příručce

Žádné komentáře