HP A8800 Routers Installation Guide Part number: 5998-1416 Document version: 6W104-20130912

Strany 2

Installing the router Figure 1 shows the steps for installing the router. Figure 1 Installation flowchart Installation prerequisites Before installi

Strany 3 - Contents

95 (5) Overload automatic protector The protector automatically opens the electric circuit when the current exceeds the threshold and closes the elect

Strany 4

Engineering labels Engineering labels are used to identify cables and devices for easy maintenance after installation. There are two types of engine

Strany 5

Figure 61 Label for power cables 12TO: (1) Cable tie (2) Dividing line on the label Generic labels A generic label is bar-shaped with fixed dimensi

Strany 6 - Preparing for installation

Figure 62 Generic label (1) Dividing line on the label (2) Cut dotted line Labels for devices A device label is used to identify the device name, m

Strany 7

Figure 63 Affixing a label Figure 64 shows the affixed labels when the cable is laid vertically and horizontally. Figure 64 Affixed labels TO:B02 0

Strany 8 - Installation tools

Figure 65 Affixing a label TO:B03–48V2 Bind cable ties on both ends of a cable. After the bundling, the finished identification plate should be on t

Strany 9

Figure 67 Affixing a generic label Affixing a label to a device Remove the device label and stick it to the device. You can stick a device label to

Strany 10 - Installing the router

Content MeaningExampleB—Chassis number Numbered in top-down order with two digits, for example, 01. C—Slot number Numbered in top-down and left-right

Strany 11

Engineering labels for optical fibers These labels are affixed to optical fibers that connect the fiber ports on the cards in a chassis, or connect f

Strany 12

Content Meaning ExampleB—Chassis number Numbered in bottom-up order with two digits, for example, 01. C—Slot number Numbered in top-down and left-ri

Strany 13

• There is no debris inside or around the rack. • The router can be installed only in a 4-post 19-inch standard rack. Mounting slide rails to the r

Strany 14

• A01-01-05-05-R—The peer end of the optical fiber is connected to Optical Receiving Interface 5 on Slot 05, Chassis 01 in the cabinet on Row A, Col

Strany 15

PGND and RTN are two copper bars, on which the terminal blocks are short-circuited, so which terminal is connected makes no difference. You only need

Strany 16 - Grounding the router

107 You can fill in the device name, model, IP address, serial number, installation address, and installation date on a device label. Figure 73 Examp

Strany 17 - Installing the power system

Cable management Label cables before you route or bundle them. For more information about labeling cables, see " Engineering labels for cables.&

Strany 18 - Installing a DC power supply

Figure 75 Binding the cables • When you route cables through sharp sheet metal penetration points or along sharp edges of mechanical parts, use bu

Strany 19 - Installing a card

NOTE: The devices in the following figures are for illustration only. Figure 77 Network cable management 110

Strany 20 - Installing an SPE subcard

111 Figure 78 Optical fiber management Use strapping tapes to carefully bind optical fibers. Avoid excessive force. For more information, see the i

Strany 21 - Connecting power cables

Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before c

Strany 22 - Connecting DC power cables

• HP Education http://www.hp.com/learn Conventions This section describes the conventions used in this documentation set. Command conventions Conven

Strany 23

114 Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as

Strany 24 - Verifying the installation

NOTE: The appearance and installation methods of slide rails depend on the slide rail types. Installing cage nuts to the rack Before mounting the c

Strany 25 - Logging in to the router

Index A C D E F G I L M O P R S T V A Affixing labels,98 C Cable management examples,109 Cable management guidelines,108 Cable routing recommendatio

Strany 26

S Safety recommendations,1 SPC card LEDs,86 Subcard LEDs,88 T Technical specifications,61 Technical support,47 V Verifying and diagnosing transceive

Strany 27

To install a cable management bracket: 1. Attach the cable management bracket to the chassis, and align the screw holes on the cable management brack

Strany 28

Figure 5 Installing the cable management bracket on the A8805/A8812 Installing the mounting brackets Before installing the router to the rack, insta

Strany 29

Installing an impedance carrier (optional) An impedance carrier is shipped with the A8808 only. You can install the impedance carrier at the rear of t

Strany 30

that the bottom edge of the slide rail aligns with the middle of the narrowest metal area between holes, and that the cage nuts are installed in the c

Strany 31 - Powering on the router

3. Insert the grounding screw into the grounding hole and tighten the screw. 4. Connect the other end of the grounding cable to the grounding strip

Strany 32

Installing a DC power supply 1. Remove the air filter frame of the power supply and gently pull the DC power supply handle out. 2. Holding the handl

Strany 33 - Configuration Guide

Installing an NEPS1800-A AC power supply 1. Pull the handle of the power supply downward to the unlock position. 2. Gently push the power supply in

Strany 34

Legal and notice information © Copyright 2011-2013 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transm

Strany 35 - Connecting an optical fiber

Figure 13 Removing the protection cover 2. Move the ejector levers of the card outward. Supporting the bottom of the card with both hands, slowly p

Strany 36 - Installing an FMT (optional)

3. Remove the blank panel (if any) from the slot to be used on the SPE card. 4. Unpack the subcard. To install a subcard: 1. Turn the ejector lever

Strany 37

Connecting an AC power cable CAUTION: NEPS3500-A requires a 16 A power cable (AC), so you must use a 16 A busbar and make sure the AC power source

Strany 38 - Hardware management

WARNING! To protect operators from being shocked, install the protection cover over the DC terminal block immediately after you connect the power cab

Strany 39 - Rebooting the router

Verifying the installation WARNING! Before verifying the installation, make sure you have turned off the power to avoid bodily injury and router da

Strany 40

Connecting the router to the network Logging in to the router The most common way to log in to a router is through the console port. It is also the pr

Strany 41

Figure 19 Connecting the router and the PC through the console port To connect the console cable: 1. Connect the DB-9 connector of the console cabl

Strany 42

Figure 20 Connection Description dialog box for HyperTerminal 2. Enter the name of the new connection in the Name box, and then click OK. The syst

Strany 43

Figure 21 Selecting a port for the HyperTerminal connection 3. Select a port from the Connect using list, and then click OK. 4. Set the Bits per se

Strany 44

Figure 22 Setting the serial port parameters 24

Strany 45 - RX loss of signal

Contents Preparing for installation ··················································································································

Strany 46 - Field Remarks

Figure 23 HyperTerminal window 5. Select File > Properties in the HyperTerminal window. 6. On the Settings tab, select VT100 for terminal emul

Strany 47 - Field Descri

Figure 24 Setting the terminal emulation parameters Powering on the router CAUTION: Before powering on the router, locate the power switch in the

Strany 48 - Troubleshooting

2. Turn on the power switch on the router. Before the router is powered on, the following information is displayed: DDR2 SDRAM test successful. Syste

Strany 49 - Fan failure

kbd->bi_immr_base = 0xff700000. Starting kernel at 0x10000 ...

Strany 50 - MPU failure

Connecting through an AUX cable You need an AUX cable when configuring a router using a remote dial-up modem. An AUX cable is an 8-core shielded cable

Strany 51 - Interface failure

Installing a transceiver module CAUTION: During installation, do not touch the golden finger of the SFP module. The installation procedures for an X

Strany 52 - Technical support

Figure 27 Connecting an optical fiber to an SFP module Installing an FMT (optional) The FMT is installed in a cabinet for winding redundant fibers b

Strany 53 - Replacement procedures

CAUTION: Do not bind cables at the air exhaust vent to prevent the cables from aging too fast. For more information, see "Cable management."

Strany 54 - Replacing an AC power supply

Hardware management This chapter describes the hardware management functions of the router. Displaying electrical label data Electrical label data

Strany 55

6 NONE Absent NONE Table 10 Command output Field Description Slot No. Slot number of a card. Brd Type Hardware type of a ca

Strany 56 - Replacing a card

Displaying the operating state of a fan ··············································································································

Strany 57

Step Command Remarks 1. Reboot a card, or the whole system immediately. reboot [ slot slot-number ] Optional. Available in user view. The precision o

Strany 58 - Replacing a subcard

Configuring temperature alarm thresholds for a card Use the following command to set temperature alarm thresholds for a card. When the temperature of

Strany 59 - Replacing a fan tray

The in-service hardware failure diagnosis includes the detection for chips, cards, and the forwarding service, and automatic fix actions taken for the

Strany 60

Field DescriptionInfo Detailed alarm information. Slot n board state is faulty. Card n is faulty. The reason may be the card is booting or the card f

Strany 61

Digital Diagnostic Monitoring : YES Vendor Name : HP Ordering Name : JD118B Table 15 Command output Field Desc

Strany 62 - Replacing a CF card

Diagnosing transceiver modules The device provides the alarm function and digital diagnosis function for transceiver modules. When a transceiver modul

Strany 63 - <Sysname> umount cfa0:

Field RemarksXFP RX loss of signal RX signal is lost. RX not ready RX is not ready. RX CDR loss of lock RX clock cannot be recovered. TX fault TX

Strany 64

42 Table 18 Command output Field DescriptionTransceiver diagnostic information Fault detection information of the transceiver module plugged in the in

Strany 65

Troubleshooting This chapter describes how to troubleshoot router installation failures. The router power supply system, fans, and cards have multipl

Strany 66 - Hardware specifications

Table 19 AC power supply LED LED Status Description Input Steady green Power is being input correctly. Off The power supply is absent or has input v

Strany 67 - Figure 45 A8805 front view

v Transceiver modules ································································································································

Strany 68 - A8808 chassis views

Table 21 Fan LEDs LED Status Description RUN Off The fan tray has failed. Steady green The fan tray is operating properly. ALM Off The fan tray is

Strany 69 - Figure 47 A8808 front view

2. Press the MPU RESET button to reset the MPU, and then verify that the corresponding RUN LED is on. 3. Make sure the MPU is seated properly. You

Strany 70 - Figure 48 A8808 rear view

47 6. If the LED is for a copper or fiber combo port, make sure the port has been activated. If not, use the combo enable { copper | fiber } command

Strany 71 - A8812 chassis views

Replacement procedures This chapter provides information about replacing components on the router. Replacing a power supply system WARNING! • Power

Strany 72 - Figure 50 A8812 rear view

Figure 30 Replacing a DC power supply (A) DC power supply to be removed (B) DC power supply to be installed Replacing an AC power supply 1. Pull th

Strany 73 - Cooling system

5. Slowly push a new power frame into the slot along the slide rails until the rear of the power frame has close contact with the backplane. 6. Use

Strany 74 - A8805 and A8812 airflow

Cleaning a power supply air filter To ensure proper ventilation of the power supply, HP recommends that you clear the air filter monthly. The NEPS350

Strany 75 - A8808 airflow

2. Remove the blank panel (if any) from the slot to be used. Keep the removed blank panel and protection cover for future use. 3. Unpack the card to

Strany 76 - Card specifications

Figure 35 Replacing a card Replacing a subcard CAUTION: When the router is operating, you must remove the SPE card before removing or installing t

Strany 77

Figure 36 Replacing a subcard (A) Subcard to be removed (B) Subcard to be installed Replacing a fan tray CAUTION: Fan trays are hot-swappable. If

Strany 78 - MPU specifications

Preparing for installation Overview This series is a line of data center routers. You can deploy the A8800 routers at the core layer and distribution

Strany 79 - SPE card specifications

3. Gently insert the new fan tray into the fan tray slot along the slide rails until it has close contact with the backplane. 4. Use a Phillips scr

Strany 80 - Subcard specifications

Figure 38 Replacing a fan tray for an A8808 (A) Fan tray to be removed (B) Fan tray to be installed Replacing a chassis air filter CAUTION: Clean

Strany 81 - OAA module specifications

Figure 39 Replacing chassis air filters for an A8808 Replacing an air filter for an A8805/A8812 1. Loosen the captive screws on the air filter, as

Strany 82 - Power supply system

Figure 41 CF card slot (1) CF card cover (2) CF card eject button (3) CF card (4) CF card LED The CF card is installed on the MPU of the router. If

Strany 83 - LED Status Description

Figure 42 Replacing a CF card Replacing a transceiver module CAUTION: When installing or removing an SFP transceiver module, do not touch the gold

Strany 84

Figure 43 Removing an SFP transceiver module Figure 44 Installing an SFP transceiver module 60

Strany 85

Hardware specifications Environmental requirements Table 22 Environment requirements Temperature RangeOperating temperature Long term: 0°C to 45°C (32

Strany 86

Figure 45 A8805 front view (1) ESD-preventive wrist strap port (2) MPU slots (slots 0 and 1) (3) LPU slots (slots 2 to 6)(4) Power supply slots (5

Strany 87

Figure 46 A8805 rear view (1) Rear cover handle (2) Grounding screw (3) Fan tray A8808 chassis views You can install one or two power supplies, b

Strany 88

Figure 47 A8808 front view (1) Fan tray (2) MPU slots (slots 4 and 5) (3) LPU slots (slots 0 to 3, 6 to 9) (4) Cable management bracket (5) Power

Strany 89 - Fan LEDs

Installation site requirements The following tables provide information about temperature and humidity, cleanness, and air quality requirements. CAU

Strany 90 - MPU LEDs

Figure 48 A8808 rear view (1) Air filter (2) Grounding screw (3) Rear cover handle 65

Strany 91 - SPC card LEDs

A8812 chassis views You can install one or two power supplies, but intermixing of AC and DC power supplies is not allowed. In this figure, four AC pow

Strany 92 - LINK and ACT LEDs

Figure 50 A8812 rear view (1) Rear cover handle (2) Grounding screw (3) Fan tray 67

Strany 93 - Subcard LEDs

Chassis specifications Table 23 Chassis specifications Model Max power consumption Weight Dimensions (H × W × D) Height (RU)A8805 2040 W (AC) 1795 W

Strany 94 - Transceiver modules

Figure 51 Fan trays (1) RUN LED (2) ALM LED Table 24 Fan LEDs LED Status Description RUN Off The fan tray has failed. Steady green The fan

Strany 95

Figure 52 A8805 airflow (1) Chassis air intake (2) Chassis air outlet (3) Power supply air intake (4) Power supply air outlet A8808 airflow The c

Strany 96

Figure 53 A8808 airflow (1) Chassis air intake (2) Chassis air outlet (3) Power supply air intake (4) Power supply air outlet If you have install

Strany 97

Card model Power consumption Net weight Dimensions (H × W × D) SPC-GP48L 67 W to 115 W 3.50 kg (7.72 lb)40 × 400 × 380 mm (1.57 × 15.75 × 14.96 in)

Strany 98

Card model Power consumption Net weight Dimensions (H × W × D) PIC-CL2G8L 18.22 W to 33 W 0.65 kg (1.43 lb) 37 × 165 × 142 mm (1.46 × 6.50 × 5.59 i

Strany 99 - Lightning protection

Item SR02SRP1F3 SR02SRP2F3 Ports • 1 console port • 1 AUX port • 1 network management port • 1 RS-232/485 port (reversed for future use) • 1 CF c

Strany 100

Rack-mounting requirements Before rack-mounting a router, make sure the rack meets the following requirements: • HP recommends that the router is mo

Strany 101 - Engineering labels

Subcard specifications Table 30 Subcard specifications Model Interface type and number Available transceiver modules and cablesPIC-GP10L 10-port 100

Strany 102 - Generic labels

Model Interface type and number Available transceiver modules and cablesPIC-CL1G8L 1-port OC-3/STM-1 channelized to E1/T1 CPOS optical interface (SFP

Strany 103 - Affixing labels

Model Interfaces Supported interface modulesIM-LB • One console port • Two USB ports (reserved) • Two 10/100/1000 BASE-T copper ports • Two GE com

Strany 104 - B02 03 12

Table 33 AC power supply LEDsLED Status Description Input (IN) Steady green The input voltage is in the normal range. Off The power supply or power s

Strany 105 - Affixing a generic label

Figure 56 NEPS3500-D DC power supply (1) Power input LED (2) Power output LED (3) Power fault LED Table 34 DC power supply LEDs LED Status Descrip

Strany 106 - Examples

• Make sure the maximum total output power of the power supplies exceeds the system power consumption. (HP recommends reserving a certain power de-ra

Strany 107

No. Specifications 2 Connector type Code (Length) Countries or regions where the type of power cables conforms to local safety regulations and

Strany 108

No. Specifications 4 Connector type Code (Length) Countries or regions where the type of power cables conforms to local safety regulations and c

Strany 109

83 No. Specifications I type 0404A01A (3 m or 9.8 ft)Australia Connector outline Power cable outline Connector outline 7 Connector type Cod

Strany 110

LEDs In this document, SPC cards refer to the interface cards prefixed with SPC, for example, SPC-GP48L, and SPE cards refer to the base cards prefix

Strany 111

4 The rack accessories and installation tools are not described in this section. The accessories and installation tools may vary depending on the rack

Strany 112

MPU LEDs Figure 57 MPU LEDs (1) CF card status LED (CFS) (2) Network management port LED (ACT) (3) Network management port LED (LINK)(4) MPU status L

Strany 113 - Cable management

LED Status DescriptionFlashing yellow Data is being transmitted and/or received. LPU status LEDs Table 43 LPU status LEDs LED Status Description R

Strany 114 - Cable management examples

LINK/ACT LED Table 45 describes the LINK/ACT LED for the interfaces on the SPC-GP48L card and the GE fiber interfaces numbered from 1 to 16 on the SPC

Strany 115 - NOTE:

88 SPE card LED The LED for all SPE cards is the same. Table 48 SPE card LED LED Status Description RUN Steady green The card is faulty or is start

Strany 116

Transceiver modules CAUTION: If you connect a long-haul (at least 40 km, or 24.86 miles) transceiver module to a short optical fiber (see Figure 58)

Strany 117 - Support and other resources

NOTE: Multi-mode optical fibers are described using a system of classification determined by the ISO 11801 standard—OM1, OM2, and OM3—which is based

Strany 118 - Conventions

Product code Description Central wavelength Connector Fiber Max. transmission distanceJD115A HP X170 1G SFP LC LH70 1510 Transceiver 1510 nm LC 9/125

Strany 119 - Port numbering in examples

OC-48/STM-16 SFP transceiver modules Table 52 OC-48/STM-16 SFP transceiver modules Product code Description Central wavelengthConnector Fiber Max. tra

Strany 120

93 Product code Description Central wavelength Connector Fiber Max transmission distanceJD120B HP X110 100M SFP LC LX Transceiver 1310 nm LC 9/125 μm

Strany 121

Lightning protection Connecting the AC power supply to a power strip with lightning protection If part of the AC power line is routed outdoors, use a