HP Integrity BL860c Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Barebones pro PC / pracovní stanice HP Integrity BL860c. HP Integrity BL860c Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Edition: 1

HP Integrity BL860c i2, BL870c i2, &BL890c i2 Server Blade Installation GuideHP Part Number: AD399-9004APublished: April 2010Edition: 1

Strany 2

Processor and supporting chipsetThe BL860c i2 Server Blade contains a processor subsystem accommodating one or two IntelItanium processor modules.Each

Strany 3 - Table of Contents

http://h71028.www7.hp.com/enterprise/cache/316735-0-0-0-121.html.Controls, ports, and LEDsFront panel view9Partition Identifier5Monarch power button1M

Strany 4 - 4 Table of Contents

Front panel LEDsStatusDescriptionItemGreen = Blade is acting as monarchbladeOff = Blade is not monarch or is notconjoinedMonarch blade indicator1Blue

Strany 5 - List of Tables

StatusDescriptionItemGreen = Server blade is powered onAmber = Standby (auxiliary poweravailable)*Off = OffBlade power LED9Green flashing = iLO Active

Strany 6

InterpretationFault/UID LED (amber/blue)Online/activity LED (green)Do not remove the drive. Removinga drive might terminate the currentoperation and c

Strany 7 - Overview

Scaleable BladeLink LEDsStatusDescriptionGreen = Scaleable BladeLink is currently active. Do notremove.Off = Scaleable BladeLink is not currently acti

Strany 8 - Server blade components

SUV Cable and PortsThe SUV port on the front of the server blade is used in conjunction with an SUV cable to connectthe server to external devices suc

Strany 9 - Power subsystem

Safety informationWARNING! Wear an ESD wrist strap when handling internal server components. AcceptableESD wrist straps include:• The wrist strap that

Strany 10

• Verify electrical requirements. Ensure that grounding specifications and power requirementsare met.• Confirm environmental requirements.Inspect the

Strany 11 - Controls, ports, and LEDs

Installing a hot-plug SAS disk driveThe server blade supports up to two hot-plug SAS drives.CAUTION: To prevent improper cooling and thermal damage, d

Strany 12 - Front panel LEDs

© Copyright 2010 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP required for possession, use or copyin

Strany 13

4. Close the lever to lock the drive into place.Installing internal componentsRemoving the access panel1. Unlock the cam on the access panel latch (if

Strany 14

Installing a processor and heatsink moduleProcessor load orderObserve the following guidelines when installing additional processors:• In a BL860c i2,

Strany 15 - Scaleable BladeLink LEDs

2. Transfer the duplicate part/serial numbers label from the processor module to the processor'sheatsink.a. Remove the duplicate yellow tear-away

Strany 16 - Rear panel view

CAUTION: During installation, after removing the protective cover from the heatsink:• Do not touch or come into contact with the thermal interface mat

Strany 17 - Safety information

CAUTION: To avoid damage to the server blade and processor, ensure the processorheatsink's locking handle is fully back against the stops, rotate

Strany 18 - Unpack the server blade

6. Secure the heatsink to the processora. Slide both plastic locking tabs into place (see callout 1 in the image below).b. Flip the latch down (see ca

Strany 19

8. Tie wrap the processor cable to the right tie point on the processor assembly.CAUTION: When the CPU is installed, dress all slack in the power cabl

Strany 20 - Removing the access panel

DIMM pair load orderTable 1-1 DIMM pair load orderCPU1CPU0——4A3A1stCPU0 only——10B9B2nd——6C1C3rd——12D7D4th——5E2E5th——11F8F6th——4A3A1stBoth CPUs loaded7

Strany 21

DIMM quad load order rulesTable 1-2 DIMM quad load orderCPU1CPU0————10B9B4A3A1stBoth CPUsloaded10B6B7A1A————2nd————12D7D6C1C3rd12D4D9C3C————4th————11F

Strany 22

DIMM locationsTo install the DIMMs:1. Remove the DIMM baffle.2. Locate the DIMM slots on the server blade system board.Installing additional component

Strany 23

Table of Contents1 Installing the server blade into the enclosure...7Overview...

Strany 24

NOTE: The server blade ships with at least two DIMMs installed in slots 3A and 4A.3. Ensure the DIMM slot latches are open.CAUTION: Use only HP low pr

Strany 25

1. Remove the mezzanine connector cover.2. Align the mezzanine connector on the option card with the mezzanine connector on thesystem board.3. Install

Strany 26 - Installing DIMMs

2. Place the access panel onto the server blade by lining up the posts on each side of the accesspanel with the keyways on the server blade chassis.3.

Strany 27 - DIMM pair load order

Removing a c7000 device bay divider1. Slide the device bay shelf locking tab to the left to open it.2. Push the device bay shelf back until it stops,

Strany 28 - DIMM quad load order rules

3. Lift the left side of the device bay shelf to disengage the three tabs from the divider wall,and then remove it from the enclosure.Removing a c3000

Strany 29 - 1. Remove the DIMM baffle

2. Remove the mini-divider or divider:• c3000 mini-divider:Push the divider toward the back of the enclosure until the divider drops out of theenclosu

Strany 30 - Installing mezzanine cards

Interconnect bay numbering and device mapping• HP BladeSystem c7000 Enclosure• HP BladeSystem c3000 EnclosureTo support network connections for specif

Strany 31 - Replacing the access panel

Interconnect bay labelsc3000 interconnect bayc7000 interconnect bayServer blade signal3 and 45 and 6Mezzanine 23 and 47 and 83 and 45 and 6Mezzanine 3

Strany 32 - Preparing the enclosure

3. Install the server blade.The server blade should come up to standby power. The server blade is at standby power if theblade power LED is amber.38 I

Strany 33

Installing the Scaleable BladeLinkNOTE: Before installing the Scaleable BladeLink for BL870c or BL890c, make sure the followingstatements are true:• A

Strany 34

Accessing UEFI or the OS from iLO MP...42UEFI Front Page..

Strany 35

Partner bladebay location rulesin half-heightblade devicebaysPartner bladesupport?Blade locationrulesSupportedenclosuresNumber ofconjoinedbladesScalea

Strany 36

Server blade power statesThe server blade has three power states: standby power, full power, and off. Install the serverblade into the enclosure to ac

Strany 37

host server and operating system. The iLO subsystem provides remote access to any authorizednetwork client, sends alerts, and provides other server ma

Strany 38 - 3. Install the server blade

To view boot options, or launch a specific boot option, press B or b to launch the Boot Manager.To configure specific devices, press D or d to launch

Strany 39

To perform maintenance on the system such as adding, deleting, or reordering boot options,press M or m to launch the Boot Maintenance Manager.To perfo

Strany 40

Installing the latest firmware using HP Smart Update ManagerThe HP Smart Update Manager utility enables you to deploy firmware components from eithera

Strany 42 - UEFI Front Page

2 Support and other resourcesContacting HPBefore you contact HPBe sure to have the following information available before you call contact HP:• Techni

Strany 43

%, $, or #A percent sign represents the C shell system prompt. A dollarsign represents the system prompt for the Bourne, Korn, andPOSIX shells. A numb

Strany 44 - OS login prompt

Standard terms, abbreviations, and acronymsCCLI Command line interfaceEEFI Extensible Firmware InterfaceSee also UEFI.ESD Electrostatic dischargeIiLO

Strany 45

List of Tables1-1 DIMM pair load order...

Strany 47 - 2 Support and other resources

IndexAaccess panelreplacing, 31antistatic wrist strap, 17Cc-Class enclosure (see enclosure)checking the inventory, 18component locations, 8confirming

Strany 48

UUEFIaccessing from iLO MP, 42saving configuration settings, 44unpacking the server blade, 18Vvirtual power button, 41Wweight of server blade, 7wrist

Strany 50

1 Installing the server blade into the enclosureOverviewThe HP Integrity BL860c i2 Server Blade is a dense, low-cost, Intel® Itanium® processor server

Strany 51

Server blade components8ICH mezzanine connector1CPU02CPU0 power connector9Mezzanine connector 3 (type 1 or 2)10CPU1 power connector3Mezzanine connecto

Strany 52 - 52 Index

For the location of the SAS disk LEDs, see “SAS disk drive LEDs” (page 13).SAS disk backplaneThe SAS disk backplane supports two small form factor har

Komentáře k této Příručce

Žádné komentáře