16.
Connect and route the battery pack power cable to the HP Smart Array P400i Controller cache
module.
17.
Install fan modules 1 and 2 ("
Remove and install a fan module
" on page
22
).
18.
Install the air baffle.
19.
Install the access panel (on page
20
).
20.
Slide the server into the rack.
21.
Power up the server (on page
18
).

Upgrading the HP Smart Array P400i Controller to support six hard drives

In certain configurations, the server may ship configured with the HP Smart Array P400i Controller and
only one data cable installed. To enable support for six hard drives, install an optional Mini-SAS 4i
0.35 m (14 in) cable from the HP Smart Array P400i Controller to the hard drive backplane.
1.
Power down the server (on page
18
).
2.
Extend the server from the rack (on page
19
).
3.
Remove the access panel (on page
20
).
4.
Remove the air baffle. ("
Remove the power supply air baffle
" on page
21
, "
Remove the processor
air baffle
" on page
22
)
5.
Remove fan modules 1 and 2 ("
Remove and install a fan module
" on page
22
).
6.
Connect and route the second cable.
CAUTION:
When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables
do not interfere with fan module installation. Be sure to route the cables around the access panel mounting
pin bracket so as not to interfere with access panel installation.

Soubor PDF · ·

Tisk

Tisknout dokument

Sdílení

Otázky k HP ProLiant Smart Array E200

K tomuto návodu zatím nejsou žádné otázky. Položte první.

Položit otázku

Odpovídáme podle návodu a uvádíme stranu. Otázka se na webu zobrazí po kontrole.

Všechny otázky a odpovědi ›

Související produkty a manuály pro Barebones pro PC / pracovní stanice HP ProLiant Smart Array E200